| Sl. No. | Item Description |
| 1 | Strip opening and descalling/gaswelding of water collector of Solar panel upto1500 Ltrs/day capacity over rooftop of 3 rd floor or fixed in ground, fins/tubes from inside, (vertical type) cleaning with concentrate acid in fix ratio and repair /copper welding (soldering) of panel including replacement of rubber washer 2 Nos of thickness 3 mm, and arresting of detecting possible leakage reassembling and reinstallation at over OTM buildings with OEM approved manufacturer complete all as specified and directed. |
| 2 | S&F in replacement of Toughened/Texture glass of 3.2 mm thik having transmission more than 85 % including coonected rubber/nut botl/nickle cladding etc in the existing solar panel |
| 3 | S&F heating element for solar water heating system of cap 3 KW of approved make. |
| 4 | S&F thermostat control for electrical back up for solar water heater as per existing. |
| 5 | S&F EPDM rubber gasket for solar collector |
| 6 | M&L for insulation for GI pipe all around of pipe with glass wool 30mm thick with and including applying bituminous compound and aluminium cladding of sizes 20 mm dia |
| 7 | M&L for insulation for GI pipe all around with glass wool 30mm thick with and including applying bituminous compound and aluminium cladding of sizes 25 mm dia |
| 8 | Day to day maintenance and inspection of chlorine dosing plant at various water supply installation inside the complex ,alongwith replacement of deffective parts of dosing plant i.e injector assembly, connecting pipes and valve of each plant including strip opening of chloronome plant and replacement of all defective parts, washers by employing one skilled mechanic to achieve satisfactory residual chlorine result at user end from 09:00 hrs to 17:00 hrs during every working day. Note :-(I) Non attending complaint of chloronome plant is subject to a recovery of Rs 2500.00 per plant per day will be recovered while claiming the payment. (ii) Supply of spare parts shall be measured and paid for separately under respective items here-in-after. |
| 9 | Supply only Orthotoline Solution in 500 mililitre Bottle Note:- Consumable in water supply installation having batch No.with manufacturing date should not exceed more than 90 days. |
| 10 | Supply and fix in replacement,high pressure transparent type Suction/Discharge PVC pipe 3/8 '' dia outer of chloronome plant, as per OEM complete all as specified and as directed. |
| 11 | Taking down defective electric motor of dosing motor 1 HP cap and supply and fix in replacement of dosing motor 1 HP cap squirrel cage type single phase 230 volt 50 Hz cap re-installation at site complete and testing complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Taking down defective electric dosing pump of any cap and supply and fix in replacement of new dosing pump set as per existing make and model complete and testing complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L for taking down defective electric motor of dosing motor 1 HP cap disconnecting delivery pipe line repair/overhauling 1 HP, AC 230 volts opening into parts cutting of burnt winding, cleaning, slots, balancing of rotor, cleaning polishing and rewinding with same gauge of PVC insulated copper wire, replacement of impeller pressure switch and cleaning including testing complete all as specified and directed |
| 14 | Supply only spare parts for Dosing cum feeding pump of chloronome system , gear type of cap 40 Gallon/per day Make:- Declibac/Perls Filter and potter and watts to be incorporated in the work |
| 15 | Rotor assembly with bearing brackets and tollerance rings |
| 16 | Coil assembly 250V 50 Hz |
| 17 | Single head feed rate control with shaft |
| 18 | Pump Head ( Ferrules 1/4'' and duckbill included) |
| 19 | Roller assebly set of 4 |
| 20 | Pump Tube (Set of Five) |
| 21 | Injection Check Valve 3/8\\" (Set of Five) |
| 22 | Weighted suction line strainer 3/8\\" |
| 23 | Diafram as per existing type and size |
| 24 | Ajitator as per existing type and size |
| 25 | Connecting nut 3/8\\" mail & femaleNote : Make of spare parts mentioned in (a) to (l) above shall be Declibac or Pearls filter as per ground requirement. |
| 26 | Supply and pouring of Calcium Hypo Chlorite 65-70% chlorine content in granular form disinfectant for water treatment packed in 45 Kg Drum in the service tank of chlorine dosing plant . Make: sree Rayalaseema Hi- srength Hypo Ltd or E-in-C Approved. Note:-Consumable in water supply installation having batch No.with manufacturing date should not exceed more than 90 days complete with manufacturers test certificate. |
| 27 | Supply only copper sulphate for water treatment as approved by GE. Note:-Consumable in water supply installation having batch No.with manufacturing date should not exceed more than 90 days. |
| 28 | Supply only Alum crystal type in swimming pool for agitation and water treatment as approved by GE. Note:-Consumable in water supply installation having batch No.with manufacturing date should not exceed more than 90 days. |
| 29 | Testing of water from NABL approved testing lab for 27 standard parameters from Pump House ,bore well in different locations at under GE IMA Dehradun complete all as specified and directed: - |
| 30 | M&L in repair of VALVE, SOLENOID 1/2\\" BSP of Boiler Plant as per existing type and size |
| 31 | M&L in repair of RECTIFIER-110-240V,AC / 180 DC, SKB 25,SIMICRON of Boiler Plant as per existing type and size |
| 32 | M&L in repair of CAP RUBBER for photocell of Boiler Plant as per existing type and size |
| 33 | M&L in repair of THERMOMETER 0-600 DEG,100 MM DIAL of Boiler Plant as per existing type and size |
| 34 | M&L in repair of HOSE METALLIC BRAIDED 3/8\\" x 40\\" LG of Boiler Plant as per existing type and size |
| 35 | M&L in repair of HOSE METALLIC BRAIDED 3/8\\" x 50\\" LG of Boiler Plant as per existing type and size |
| 36 | M&L in repair of BURNER ROD OBT 50- 352 MM LONG of Boiler Plant as per existing type and size |
| 37 | M&L in repair of HOOTER ROUND of Boiler Plant as per existing type and size |
| 38 | M&L in repair of SEALS SET of Boiler Plant as per existing type and size |
| 39 | M&L in repair of PRESSURE GAUGE , 0 TO 40 KG 68 MM, 1/4\\" BSP BOTTOM CONNECTION of Boiler Plant as per existing type and size |
| 40 | M&L in repair of NOZZLE BYPASS ASSEMBLY40 GPH 2 MM ORIFICE of Boiler Plant as per existing type and size |
| 41 | M&L in repair of CONTINUOUS CURRENT MAGNET 180 V,DC of Boiler Plant as per existing type and size |
| 42 | M&L in repair of ELECTRODE 800 MM LONG of Boiler Plant as per existing type and size |
| 43 | M&L in repair of ELECTRODE CAP WITH HT CABLE of Boiler Plant as per existing type and size |
| 44 | M&L in repair of NOZZLE HOLDER of Boiler Plant as per existing type and size |
| 45 | M&L in repair of SEQUENCE CONTROLLER LAL 2.25 WITHOUT BASE PLATE of Boiler Plant as per existing type and size |
| 46 | M&L in repair of PHOTORESISTOR QRB 3 of Boiler Plant as per existing type and size |
| 47 | Supply only PH Correction chemical for softener plant as approved by EIC. |
| 48 | Supply only Sodium Chloride for softener plant |
| 49 | Supply only resin for softener plant Please Enable Macros to View BoQ information |
| 50 | Supply only resin for softener plant Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender