Tender For Construction Work Of Cow Shed In The Residential C Us Of District Magistrate Pratapgarh.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Jul 2026
11 days left
EMD
24000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pratapgarh → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Work Of Cow Shed In The Residential C Us Of District Magistrate Pratapgarh.
BOQ
| Sl. No. | Item Description |
| 1 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the pheriphary of the area cleared. |
| 2 | Earth work in exacavation in foundation in ordinary soil including lift upto 1.5 m and lead upto 30m. and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 30 m. |
| 3 | Filling with avilable earth in trenches, plinth, sides of foundation, etc.in layers not exceeding 20 cms in depth consolidating each deposited layer by ramming and watering including lead upto 50m and lift upto 1.5m. |
| 4 | Filling of carted earth ( 5 Km) in trenches, plinth, sides of foundation, etc.in layers not exceeding 20 cms in depth consolidating each deposited layer by ramming and watering including lead upto 50m and lift upto 1.5m. |
| 5 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 fine sand : 8 gradedbrick aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. |
| 6 | R.C.C. work with cement approved coarse sand and 2 cm (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1 cement : 1.5 coarse sand : 3 aggregates) , in lintels of doors and windows excluding supply of rienforcement and its bending the same with 24 WG binding wire and necessary centring and shuttering etc and also including supply of all materials labour and tools and plants etc. required for proper completion of the works. Strength of the concrete shall not be less than M-20. For Columns Footings |
| 7 | Same as above Item No. 6 But for Columns |
| 8 | Same as above Item No. 6 But for Lintel band |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Class 150 brick work in 1:6 cement and C.sand in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work. (PWD-303) |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 15 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in an over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 16 | Providing and Fixing of ISA 50X50X6x40X40X5 truss including drilling holes riveting or welding where necessary and there fixing required for proper completion of the work |
| 17 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sgm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, total excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR-12.50 |
| 18 | External Plastering 12mm thick plaster with cement mortar in proportion of 1:6 cement &fine sand of 1.25 FM for external walls Chapter 13 S.No 10 PWD 586 |
| 19 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 20 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park& lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape,madeby table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into thes and bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. 80mmthick Cement concrete paver block ofM-30 grade with approved colour, design & pattern. |
| 21 | Colour washing such as green, blue or buff to give an even shade :New work (two or more coats) with a base coat of white washing with lime |
| 22 | 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 23 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C |
| 24 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required Group -C |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 26 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 28 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 29 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 30 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 31 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 32 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 33 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 34 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps |
| 35 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 36 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. 1 X 22 W CAT-AAA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST