Tender For Repair And Maintenance Of Ceiling Fans,Exhaust Fans,Wall Mounted Fans, Pump Motors, Starters And Other Misc Works At Afs Pathankot
Tender Value
42 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
19 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Ceiling Fans,Exhaust Fans,Wall Mounted Fans, Pump Motors, Starters And Other Misc Works At Afs Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | Taking down Ceiling Fan,Exhaust Fan,Wall Fan, Pedestal Fan of any size from roof, wall dismantling blades and removing fan and blades to MES Store Yard For Repair complete all as specified and directed |
| 2 | Dismantling of unservicable Ceiling fan/Exhaust fan/Wall fan/Pedestal Fan at any location and checking defective parts removing capacitor carefully for overhauling checking serviceability of bearings/bush, winding etc cleaning the fan reassembling after replacing the unserviceable parts (New Items are to be paid under relevant item of the Sch 'A') and testing the same complete all as specified and directed |
| 3 | Hanging only Celing fan.Exhaust Fan,Wall mounting Fan, Pedestal fan and connecting up Ceiling rose to fan connector complete all as specified and directed . |
| 4 | Cutting of old brunt winding of Celing fan and Rewinding of ceiling fan with New super enemalled copper same gauge wire including varnishing, drying paper insulation material complete of 1200 mm sweep.complete all as specified and directed |
| 5 | Cutting of old brunt winding of Celing fan and Rewinding of ceiling fan with New super enemalled copper same gauge wire including varnishing, drying paper insulation material complete of 1400 mm sweep.complete all as specified and directed |
| 6 | Cutting of old brunt winding of Exhaust fan and Rewinding of Exhaust fan with same gauge as per existing gauge super enamalled copper wire including varnishing, drying paper insulation material complete of 450 mm sweep.complete all as specified and directed |
| 7 | Cutting of old brun winding of Exhaust fan and Rewinding of exhaust fan with same gauge as per existing gauge super enamalled copper wire including varnishing, drying paper insulation material complete of 300/380 mm sweep.complete all as specified and directed |
| 8 | Supply only fan capacitor 4 mfd complete all as specified and directed make universal / Asian/Epcos |
| 9 | Supply only fan capacitor 3.15 mfd complete all as specified and directed make universal / Asian/Epcos |
| 10 | Supply only fan capacitor 2.5 mfd complete all as specified and directed make universal / Asian/Epcos . |
| 11 | supply and fixing Ceiling fan shaft of standard size including taking out old shaft, complete and all as specified. |
| 12 | Supply and fix metal louver for exhaust fan of size from 225 mm to 450mm sweep or as per sample complete all as specified and directed by EIC |
| 13 | Supply and fix Exhaust fan motor for 300 mm sweep (Dark Grey in colour) matching with existing motor make and removing old unserviceable motor from exhaust fan complete all as specified and direceted. |
| 14 | Supply & fix Wall mounted Air Circulator fans 230 volts single phase oscillating 300 mm sweep suitable for wall mounting complete all as directed by Engr In Charge. |
| 15 | Supply and Fixing Exhaust fans AC single phase Plastic body 230/ 240 V of size 250 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed. |
| 16 | Supply and Fixing Exhaust fans AC single phase Plastic body 230/ 240 V of size 300 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed. |
| 17 | Supply and Fixing Exhaust fans AC single phase Steel body 230/ 240 V of size 300 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed. |
| 18 | Supply and Fixing Exhaust fans AC single phase Steel body 230/ 240 V of size 380 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed. |
| 19 | Supply and Fixing Exhaust fans AC single phase Steel body 230/ 240 V of size 450 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed. |
| 20 | Supply only ball bearing suitable for ceiling fan upto 1200/1400mm sweep complete and all as specified |
| 21 | Supply only ball bearing for Exhaust Fan/Pedestal Fan/air circulator/Table Fan upto 450mm sweep complete and all as specified . |
| 22 | Cleaning thoroughly Pedestal Fan, Wall Fan, Exhaust Fan, Ceiling fans 48\\"/56\\" (1200mm / 1400mm) sweep with Kerosene Oil and painting with one coat of synthetic enamelled paint including preparation of surfaces, complete all as specified & directed by Engineer-in-Charge |
| 23 | Supply and fixing in replacement of wire guard/grill suitable for pedestal/Air circulator fan upto 500mm sweep complete (as per sample) and all as directed by Enge-in-Charge. |
| 24 | Supply and fixing in replacement of fan blade set heavy duty suitable for Pedestal Fan /Air Circulator fan 400/500 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge. |
| 25 | All as per item No above but made of plastic suitable for fans upto 300mm sweep complete al as specified and directed by Engineer-in-charge. |
| 26 | Supply and fixing fan blade set 1200/1400mm sweep Ceiling Fan complete (as per sample) and all as directed by Engineer-in-Charge |
| 27 | S&F ceiling fan hanging hook clamps (for fixing to ceiling fan rod) made with using GI of suitable size as directed and with heavy duty rubber insulator and two Nos nuts and one bolts including split pin complete all as directed. |
| 28 | Supply and fix in replacement of PVC insulated flexible copper conductor cable 3 core of size 0.75 sqmm cut to length as required for connection from connector block of ceiling fan to ceiling rose/connector block of wiring complete all as specified and directed by Engineer-in-Charge. |
| 29 | Suply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge. |
| 30 | Supply only gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep complete all as specified and directed by Engineer-in-Charge. . |
| 31 | Supply and fix in replacement of rubber reel with nut bolts of ceiling fan with rubber reel heavy duty for hanging fan complete all as specified and directed by Engineer-in-Charge. . |
| 32 | Supply and fix in replacement of connector block of ceiling fan of suitable size of approved quality complete all as specified and directed by Engineer-in-Charge. . |
| 33 | Supply and fix in replacement of down rod 90 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete and all as directed by Engineer-in-Charge |
| 34 | Supply and fix in replacement of down rod 60 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete and all as directed by Engineer-in-Charge |
| 35 | Disconnecting electrically dismantling and taking out electric energy meter any type and capacity and depositing to MES Store Yard complete including Supply and fix single phase temper proof Electric Energy meter with LCD display 240 volts 2 wire system, 10-60 amps, 50 HZ having accuracy class 1.00 as per IS-13779 complete with all standard anti temper features including logging & display of tamper data complete including sealing properly using lead seals and wires as required complete all as specified and directed by Engineer-in-Charge. |
| 36 | All as per item No. above but three phase temper proof Electric Energy meter with LCD display 415 volts 4 wire system, 10-80 amps, complete all as specified and directed by Engineer-in-Charge |
| 37 | Checking of electric energy meter Single phase/Three phase up to 80 Amps after disconeeting proper electric conection from main board and refixing in same or other location incl sealing proper lead seals and wires as required complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixing in replacement Meter box suitable for fixing of two meters with locking arrangement of suitable size including fixing old meter in new box all as per directed by Engr-in-Charge |
| 39 | Supply and fixing in replacement Meter box suitable for fixing of one meters with locking arrangement of suitable size including fixing old meter in new box all as per directed by Engr-in-Charge |
| 40 | S&F Meter Distribution Borard made out of Thermoplastic polycarbonate of size 600x600x170 mm (dust proof & weather proof ,Shock proof, rust proof ,corrosion free ,acid & Chemical resistance ,UV resistance ,Halogen free & freerecyclable material) wiyh 230v Ac 50 HZ 3 Wire , Gasket shall be embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04 Nos including taking out u/s broken/rusted box of any size and type complete all as specrified and directed. Make Hensel / Secure/Sintex |
| 41 | Welding / brezzing of broken DB any size Pannel door / bus bar pannel door / street light junction box door with suitable size of CI/MS hinges to suitable for locking arrangement to all type of doors and painting the same door as per existing colour all as directed by Engr In Charge. |
| 42 | Repair & maintenance of Geyser of 25/50 Ltrs capacity existing make, carefully by disconnecting elect & water connection, dismantling and inspecting all the parts, for its serviceability, cleaning of serviceable parts i.e. Heating element, base assy, connecting lead, thermostat, electrical contact, electrical wiring, indicators, safety valves, vacuum control/pressure reducing valve, PVC connection, inner tank, outer tank, glass wool insulation etc and refixing the same after replacement of unserviceable parts matching with existing make and sizes as mentioned above, re-assembling,, reconnecting,refixing with electrical & water connections and testing complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of BOQ. |
| 43 | Supply and fixing in replacement of unserviceable 50Ltr capacity internal tank of geyser with copper tank heavy duty guage with double lapped joint 50 ltr capacity suitable for geyser of any type/make with necessary screws, nut bolts gasket etc complete and all as specified including taking down of Geysers and reassembling, testing and reinstallation after repair complete and all as specified and directed by Engineer-in-Charge. |
| 44 | All as per above but 25 Ltrs capacity complete all as specified. |
| 45 | Supply and fixing in replacemet of old usnerviceable syphon assembly for geyser having hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as directed by Engr-in-Charge. |
| 46 | Supply and fixing in replacement of old unserviceable heating element with heating element AC 230 volt of rating 1500 watt complete all as specified. |
| 47 | All as per Srl above but of rating 2000 Watt capacity complete all as specified. |
| 48 | Supply and fixing in replacement of old unserviceable Thermostat switch with Thermostat switch for geyser AC 230 volt adjustable range from 60 degree celslus complete all as specified. |
| 49 | Supply and fixing in replacement of old unserviceable PVC connection with PVC connection 15mm bore (450mm long) complete with brass nuts at water temprature upto100 degree celceus complete all as specified. |
| 50 | Supply and fixing in replacement of fusible/safety plug melting at 95-100 degree centigrade suitable for any type/make of Geyser complete and all as specified. |
| 51 | Supply and fixing in replacement of old unserviceable cable with PVC sheathed, copper conductor, 3 core 2.5 Sqmm complete all as specified.Make: Havells/L&T/Grandlay |
| 52 | Cleaning thoroughly gyser 25/50 Ltr capacity with Kerosene Oil and painting with two coat of synthetic enamelled paint including preparation of surfaces, change the U/S lamp any type and writing MES No after painting complete all as specified & directed by Engineer-in-Charge |
| 53 | M&L for wall fastners of size 100 mm long 8mm dia with double washers incl grouting and make good the wall surface with cement mortar (1:4) for fixing water heater after removing the existing unserviceable nuts,bolts and washers complete all as specified and as directed. |
| 54 | Supply and fix in replacement of Plug top 3 pin 16 amps AC 230 Volts complete all as specified and directed. Make Cona/Anchor/Havells |
| 55 | Supply and fixing Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp piano flush type ISI marked complete all as specified and directed..Make Cona/Anchor/Havells |
| 56 | Supply and fixing Switch piano flush type single pole, one way, 230 volts 15/16 Amps ISI marked complete all as specified and directed.Make Cona/Anchor/Havells |
| 57 | Supply and fix in repair gun metal Stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends of size 15 mm bore , for geyser connection complete all as specified and directed. Make Cera/Prayag/Jaguar |
| 58 | S&F Sheet metal enclosures with socket plug Top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete 20 Amp capacity. |
| 59 | Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m deep and getting out for pipe lines complete all as specified. |
| 60 | Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick all as specified and directed. |
| 61 | Removing excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by EIC . |
| 62 | S/F GI tubing medium grade ISI marked with all fittings and fixed complete to walls or laid in trenches of following sizes complete all as specified and directed by EIC .Make-Swastic/Prakash/Jindal/BST(a) 25 mm bore |
| 63 | (b) 20 mm bore GI tubing medium grade complete all as specified and directed. |
| 64 | (c) 15 mm bore GI tubing medium grade complete all as specified and directed. |
| 65 | Gun metal globe or gate valves,with iron wheel head,screwed both ends from iron pipes and fixed in repair of following sizes:-Make-Neta/Leader/Sant/Bir(a) 25 mm bore. |
| 66 | (b) 20 mm bore. |
| 67 | (c) 15 mm bore. |
| 68 | Supply and fix rotational moulded polythylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified of capacity 500 Ltr complete all as directed by Engr-in-charge. |
| 69 | Supply and fix rotational moulded polythylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified of capacity 1000 ltr complete all as directed by Engr-in-charge. |
| 70 | Supply and fix ball brass valves high pressure with polythene float and fly nut complete screwed for pipe or brass ferrule and fixed of size 20 mm bore complete all as specified and directed by EIC. |
| 71 | Supply and fix bib taps , cast copper alloy with crutch or butterfly , handle , screwed for iron pipes of 15 mm bore complete all as specified and directed by EIC. |
| 72 | Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator light fittings etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge. |
| 73 | M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in and including medium grade concealed PVC conduit 20 dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule). (a) One light point/ /Fan/Exhaust /bell buzzer point controlled by one, one way switch |
| 74 | (b) One three pin 5 Amp socket on same board with other switches. |
| 75 | (c) One three pin 5 Amp socket on independent board |
| 76 | (d) One light point controlled by one, two way switch |
| 77 | All as per item No. above here in but with 2.5 Sqmm (nominal area) wire/cable for phase & neutral for one 3 Pin 15 amp socket on independent board including one 2.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLS,1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.Make of the PVC FRLS Wire is Havells/Finolex/KEI .The make of conduit and its accessories should be polycab/AKG/Precision. |
| 78 | M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in existing steel/PVC conduit with existing sunken box, for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule).(a) One light point/ bell buzzer point controlled by one, one way switch |
| 79 | (b) One three pin 5 Amp socket on same board with other switches. |
| 80 | (c) One three pin 5 Amp socket on independent board |
| 81 | (d) One light point controlled by one, two way switch |
| 82 | All as per item No. above here in but with 2.5 Sqmm (nominal area) wire/cable for phase & neutral for one 3 Pin 15 amp socket on independent board including one 1.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLS,1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge |
| 83 | S&F switch piano flush type single pole one way 230 Volts 5/6 Amp complete all as specified and directed.Make Cona/Anchor/Havells |
| 84 | S&F switch piano flush type single pole two way 230 Volts 5/6 Amp complete all as specified and directed. ..Make Cona/Anchor/Havells |
| 85 | S&F socket outlet 3 pin, 230 Volts 5/6 Amps flush type multipurpose 5 pin complete all as specified and directed..Make Cona/Anchor/Havells |
| 86 | S&F bell push flush type 5 Amps 230 Volts single pole complete all as specified and directed...Make Cona/Anchor/Havells |
| 87 | Supply and fixing Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp piano flush type ISI marked complete all as specified and directed...Make Cona/Anchor/Havells |
| 88 | Supply and fixing Switch piano flush type single pole, one way, 230 volts 15/16 Amps ISI marked complete all as specified and directe..Make Cona/Anchor/Havells |
| 89 | S&F Call bell ding dong type AC 230 Volts single pole complete all as specified and directed..Make Cona/Anchor/Havells |
| 90 | S&F step type regular socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 120 watts...Make Cona/Anchor/Havells |
| 91 | S&F ceiling rose surface bakelite 3 terminals of size 65x25mm. complete all as specified & directed. ..Make Cona/Anchor/Havells |
| 92 | S&F lamp holder polycarbonate insulated body with back plate complete all as specified & directed..Make Cona/Anchor/Havells |
| 93 | Supply and fix in repair Pristine Spike LED light 10 Watt LED 3000K premium category suitable for environmental with IP 65 that beauty transforms complete all as specified and directed. Make: Havells/Crompton/Bajaj |
| 94 | S & F in repair Integra Round Surface mounted downlights 15 Watt LED with aluminium housing and heat sink for better thermal performance . complete all as specified and directed. Make Havells/Crompton/Bajaj |
| 95 | S & F in repair wall mounted LED Tube light fitting 20 Watts surface mounting general purpose LED Batterns including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round blocks including complete all as specified and directed.Make Havells/Crompton/Bajaj |
| 96 | S & F in repair wall mounted LED Tube light fitting 10 Watts surface mounting general purpose LED Batterns including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round blocks including complete all as specified and directed. Make Havells/Crompton/Bajaj |
| 97 | S & F in repair Integra NEO recessed mounted 15 Watt downlight with low depth aluminium heat sink, available in round shape . PC diffuser in white powder coated finish with independent elevtronic low THD LED driver complete all as specified and directed. Make Havells/Crompton/Bajaj |
| 98 | S & F in repair in repair LED panel Square (2'X2') Plano Taps recess mounted luminaires which suites various ceiling types with tapered housing makes in most flexible to install in low clerance ceiling .including making connections with 2 core flexible copper wire 0.50 Sq mm Complete all as specified and as directed by Engr-In-Charge. Make Havells/Crompton/Bajaj |
| 99 | S&F in repair LED panel Square (1'X1') recess mounted light fitting including making connections with 2 core flexible copper wire 0.50 Sq mm Complete all as specified and as directed by Engr-In-Charge. Make Havells/Crompton/Bajaj |
| 100 | S & F in repair sleek LED Bulk head fitting 10 watt suitable for outdoor and indoor areas in perfect synchronization with functionality and aesthetics complete all as specified and directed. Make: Havells/Crompton/Bajaj |
| 101 | S & F in repair LED Building Security light fitting 30 watt energy saving environmental friendly long life LED Street light made up pressure die cast aluminium housing with high efficiency LEDs complete with fixing arrangements all as specified and directed. Make: Havells/Crompton/Bajaj |
| 102 | M&L sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4.0 Sqmm (nominal area) drawing in and including 20mm dia medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 4.0 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified & directed. (Note: Three run 4 Sqmm cable and one run conduit shall be measured as one run.) |
| 103 | M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 4.0 Sq.mm. (nominal area)drawn in existing surface conduit/existing concealed conduit and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 4.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Make:the make of wire should be Havells/L&T/Polycab/Finolex |
| 104 | M&L sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6.0 Sqmm (nominal area) drawing in and including 20 mm dia medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 6.0 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified & directed. (Note: Three run 6 Sqmm cable and one run conduit shall be measured as one run.) |
| 105 | M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6.0 Sq.mm. (nominal area)drawn in existing surface conduit/existing concealed conduit and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Make:the make of wire should be Havells/L&T/Polycab/Finolex |
| 106 | S & F in repair of Sheet Metal Enclouser Double door DB 415 volts, 4 way with 200 Amps rated bus bar Three pole & neutral (TPN) fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface complete all as specified and direceted. Make: Legrand, Schneider, Siemens |
| 107 | S & F in repair of Sheet Metal Enclouser Double door DB 240 volts, 12 way with 200 Amps rated bus bar Single pole & neutral fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface complete all as specified and direceted. Make: Legrand, Schneider, Siemens |
| 108 | S & F in repair of Sheet Metal Enclouser Double door DB 240 volts, 8 way with 200 Amps rated bus bar Single pole & neutral incl fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface complete all as specified and direceted. Make: Legrand, Schneider, Siemens |
| 109 | S & F in repair of Sheet Metal Enclouser Double door DB 240 volts, 4 way with 200 Amps rated bus bar Single pole & neutral incl fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface complete all as specified and direceted. Make: Legrand, Schneider, Siemens |
| 110 | S & F in repair MCB Single Pole Neutral C Curve 230 volts of capacity 32 Amp 10 KA complete all and specified and directed by Engr-in-Charge. Make-Legrand Cat no 408617or equivlanet model in Schnieder/Siemens |
| 111 | S & F in repair MCB Single Pole of cap 6-32 Amp, C Curve 240 volts 10KA complete. Make-Legrand Cat no 408587 to 408595 or equivlanet model in Schnieder/Siemens |
| 112 | S & F in repair MCB, 63Amp, TPN breaking capacity 10KA, 415 Volt, 50 Hz complete all and specified and directed by Engr-in-Charge. Make- Legrand Cat no 408683 for MCB or equivlanet model in Schnieder/Siemens |
| 113 | M&L for Distribution board Vertical type TPN 4 Way (VTPN) double door, including MCCB 100 Amps MCCB, 4 pole as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection incl taking out old u/s complete. |
| 114 | M&L for service connection with 6.0 Sq mm twin core Weather proof multistranded aluminium conductor cable PVC sheathed PVC insulated round suspended with earthing and clamp etc from Pole to pole complete including desmantling of old unserviceable service connection with suspended wire and insulator shall be removing from site. |
| 115 | All as per item No. here in above but size of cable 10 Sqmm twin core. |
| 116 | M&L in replacement of 40mm dia steel tubes (light grade) galvanised with fittings including clamps fixed on wall for protection of cable at building staircase including plaster work and white wash after cutting on wall where necessary and making good disturbed surface area complete all as specified and directed. |
| 117 | Supply and fix in replacement Ceiling Fans complete with blades , down rods, Electronic regulator and all accessories 230 V 1200 mm Sweep Minimum air delivery 210 CFM with service value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC) complete all as specified and directed.Note: Old unserviceable ceiling fan deposited to AGE E/M Store yard. |
| 118 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel body complete all as specified and directed. |
| 119 | Supply and fixing desert cooler water pump suitable for 25 Watt to 40 Watt pumps , Voltage 220 V , 50 Hz completely water proof and designed to be fully submerged complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender