Tender For Repair/ Maintenance Of Ceiling Fan, Wall Mounted Fan, Pedestal Fan, Meter, Internal Wiring, Fitting, Fixture And Allied Works At Yeour And Street Light Fittings, Poles, Cables, Earthing, Lightning Arrester And Allied Works At Af Station Ka
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Ceiling Fan, Wall Mounted Fan, Pedestal Fan, Meter, Internal Wiring, Fitting, Fixture And Allied Works At Yeour And Street Light Fittings, Poles, Cables, Earthing, Lightning Arrester And Allied Works At Af Station Kanheri Hills Under Ge (Af) Thane.
BOQ
| Sl. No. | Item Description |
| 1 | S&F Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 20 to 120 Watt, complete all as specified and directed by Engineer-in-Charge. |
| 2 | S&F Surge Protection Device suitable for LED Light Fitting of capacity 20 to 120 Watt Single Phase 50 Hz, complete all as specified and directed by Engineer-in-Charge. |
| 3 | S&F in repair Multi LED Street Light Fitting of capacity 60 Watt IP 65, having Die-cast Aluminium Housing, Weather Proof with Accessories and connecting up with and including PVC insulated Copper Conductor Cable 1.5 Sqmm, Single Core including Taking down unserviceable Street Light Fittings from the Electric Pole, complete all as specified and directed by Engineer-in-Charge. |
| 4 | M & L Integral Decorative LED 8 Watt Bollard Energy Saving, Environmental Friendly aesthetically designed with opal acrlylic with IP-65 Protection, providing electric connection with suitable PVC copper flexible conductor, providing PCC 1:3:6 (20mm graded aggregate) work of size 300x300x450mm including necessary formwork and earth work, complete all as specified and as directed by Engineer-in-Charge. Cat Part No. Havells LHEVBDP7IN6K008 or equivalent. |
| 5 | Supply & fixing in replacement Integral LED aviation light 30 watt comprising of aluminium housing with polycarbonate enclosure with IP-65 protection, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fixing in repair LED flood light 210 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Ditto all aas per I No. 6 but 100 watt, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Ditto all aas per I No. 6 but 400 watt, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fixing Polycarbonate gate light fixture, Moon opal shaped Havells Cat part No. LHFXB0N1TN5Q020 (Moon 250(Opal)) with 15 W LED bulb B22 Base suitable for fixing on 40/50 mm dia pipe, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply and fixing in repair post top lantern LED type 40/45 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete withdriver and lamp complete including PCC work, complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per Srl Item No 10 above but Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp base 20 Watt, bolts etc complete all as specified and directed by Engineer-in-Charge. |
| 12 | S&F in repair LED Solar street light fitting 24 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately), complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing, complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for for applying two coat of Cement based paint on PCC poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of PCC Poles complete all as specified and directed by Engineer-in-Charge.Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces. |
| 15 | M&L for for applying two coat of Silver paint on GI poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of G I Poles complete all as specified and directed by Engineer-in-Charge.Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces. |
| 16 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) as in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling PCC Copping and/or removing damaged PCC Copping, complete all as specified and as directed by Engineer-in-charge. |
| 17 | M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 METRE long bent to shape as per specified for fixing Street Light Fitting including applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket, complete all as specified and as directed by Engineer-in-charge. |
| 18 | S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and as directed by Engineer-in-charge. |
| 19 | M&L for greasing, oiling,servicing & testing of 3 phase motor & winch of high mast light upto 25mtrs.Taking down the double drum winch with luminaire mounting arm, pulley assembly, aviation obstruction light, lightning arrester spike and replacement of unserviceable flood light, checking of electric cable connection,stainless steel wire rope, junction box complete all as specified and as directed by Engineer-in-charge. (Note :-Necessary spare, other related work will be measured in respective items. (b) Necessary tools, ladder ,safty equiptment for electrician and helper will be arrange by the contractor in his own cost. (c) Taking down and refixing is also including the cost . |
| 20 | Replacement of three phase motor for high mast as per existing capacity and size to drive double drum winch, complete all as specified and as directed by Engineer-in-charge. |
| 21 | Supply only chain of suitable size & length as per existing for driving double drum winch of high mast complete all as specified and as directed by Engineer-in-charge. |
| 22 | Supply only stainless steel wire rope for high mast upto 25 mtrs height of grade AISI 316, 7/19 construction, having minimum dia 6 mm, suitable for breaking load capacity 2350 Kgs complete all as specified and as directed by Engineer-in-charge. |
| 23 | Supply only ERP/PCP trailing cable flexible type of size 2.5 sqmm 5 core complete all as specified and as directed by Engineer-in-charge. |
| 24 | S&F in replacement of digital type street light timer with 24 Hrs opeartion setting single phase complete all as specified and as directed by Engineer-in-charge. |
| 25 | S&F in replacment of ML-4 contactor 63 Amps Three phase 430 volt AC complete all as specified and as directed by Engineer-in-charge. |
| 26 | Supply,lay and testing in replacement cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 25 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and as directed by Engineer-in-charge. |
| 27 | All as per item No.29 above but of size 16 sqmm, 4 core complete all as specified and as directed by Engineer-in-charge. |
| 28 | S&F in repair copper strip of 20 x 3.15 mm as roof conductor and down conductor till test point including removing of ol unsv strip , complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in repair aluminium strip of 25 x 3.15 mm as roof conductor and down conductor till test point including removing of ol unsv strip, complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in repair galvanised iron strip of 32x6mm as roof conductor and down conductor till test point including removing of ol unsv strip complete all as specified and directed by Engineer-in-Charge.Note for I No- 28 to 30 Galvanised strip to be jointed through brazing only |
| 31 | S&F in repair of single pointed soild copper rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor, complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in repair single pointed soild Aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor, complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F,in repair, single pointed soild copper rod 1 m long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor, complete all as specified and directed by Engineer-in-Charge. |
| 34 | S & F in repair test point terminals block and supply and fixing the same. The terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head of gun metal screw , including removing old unsv complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 35 | S & F in repair test point terminals block and supply and fixing the same. The terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head of gun metal screw , including removing old unsv complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender