Tender For Balance Work Of Construction of Primary And Middle School Building At Naulakha In Tehsil Sunder Nagar Distt. Mandi (H.P.) Sh:- Construction Of G.M.S Toilet Block With S.I Works)
Tender Value
3.99 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
6 days left
EMD
8100
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mandi → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Balance Work Of Construction of Primary And Middle School Building At Naulakha In Tehsil Sunder Nagar Distt. Mandi (H.P.) Sh:- Construction Of G.M.S Toilet Block With S.I Works)
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size) with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 3 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for : with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. (1) Suspended floors, roofs, landings, balconies and access platform |
| 5 | Edges of slabs and breaks in floors and walls |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size). with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. (1) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge.(1) Cement mortar 1:4 (1 cement :4 coarse sand) |
| 9 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : |
| 10 | 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 11 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 12 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 13 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 ofapproved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with greycement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 14 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 15 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (15 mm nominal bore) with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 16 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 17 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(15 mm nominal bore) with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 18 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 19 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :(15 mm nominal bore) with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 20 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 21 | Providing and fixing PVC floor trap of Superior quality as per direction of Engineer-In-Charge with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 22 | Providing and fixing uplasticised PVC connection pipe with brass unions with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 23 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. (1) 110 mm diameter |
| 25 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. 1. Coupler110 mm diameter |
| 26 | 110 mm bend |
| 27 | Supplying and fixing C.I. cover without frame for manholes :455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 28 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood 35 mm thick shutters with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 29 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge.( 1.) 20 mm nominal outer dia Pipes |
| 31 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. |
| 32 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall with in all leads and lifts and other incidentials complete and as per the entire satisfaction and direction of Engineer-in-Charge. Please Enable Macros to View BoQ information Compatibility Report for BOQ(2).xls Run on 1/20/2024 14:42 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 'BoQ1'!A1:II82 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 14.0 |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender