Tender For Providing And Fixing Of Street Light And High Mast System To Cover Dark Spot And 3 Years annual maintenance contract At Ia Bhuragarh, Banda
Tender Overview
Project Description
Tender for Providing And Fixing Of Street Light And High Mast System To Cover Dark Spot And 3 Years annual maintenance contract At Ia Bhuragarh, Banda
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 31-Jul-2026 | Extension of Date | Date | 07-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | (UPPWD Sch. No.652 )Supply and fixing of 16 mtr. High mast shaft of approved make with rising system hot dip glavanized inside & out side dip, heaving pole sheet thickness 3 mm. Top dia minium 150 mm bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferntial weld, with accessoies for high mast such as head frame suitable for 12 limminaries & its control gear boxes 1.5 HP power tool moter 3 point suspension system with steel wire rope 6 mm. dia double drum winch including making suitable foundation as per manufature drawing/ site requirment along with foundation bolts nuts, washer, anchor plates etc complete in all respects(With three year All Type Repair & Maintenance) . as per (Bajaj /Philips/Wipro Make) |
| 2 | ( UPPWD Sch. No.1455 )Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 200 watt confirming to IP 66 protection complete in all respects (With 5 Year Gurantee (3+2) Three year all type (including Damge & Theft) Repair And Maintenace & Extra Two Year Gurantee) . Catt. AA as per(For High Mast 16 Meter)(Bajaj /Philips/Crompton/Wipro Make) |
| 3 | ( UPPWD Sch. No.1424 Cat -AA)Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. Make as per direction of the Engineer- incharge Catt. AA as per UPPWD Sch. No.1424 Cat -AA (Bajaj, crompton, Philips, Wipro Make) |
| 4 | Supply & Fixing of 32 MM Dia 1.20 Mtr long G.I Pipe Bracket For Fixing of LED lights complete in all respects with clamp etc as per sanctioned vide |
| 5 | (uppwd Item no 610)Supply & fixing steel tubular pole 9 Metre long designated 410 SP-29, 129Kg( GI Bottom ) complete with 1/6 of overall length of pole below ground level with 45cm dia cement concrete with 45cm dia cement plinth around the pole and 45cm above the fround level complete it all respect. |
| 6 | (UPPWD sch No. 623 )Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint |
| 7 | Supply & fixing of as per Design Suitable for Fixing Shackle Insulator , Made out of size 50x6 mm M.S.flat Including all bolts with nuts and washers etc. complete in all respect as per UPSIDC Sch. No. 13.1 |
| 8 | ( UPPWD Sch. No. 807(e)(ii))S/F of following capacity of automatic street light cubical cantrol panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with cintractors HRC fuses, isolating switch metering instuments box with CTS etc. as per (25 Amp. TPN) |
| 9 | (UPPWD Sch. No. 807(f)(ii))S/F of following capacity of automatic street light cubical cantrol panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with cintractors HRC fuses, isolating switch metering instuments box with CTS etc. as per UPPWD Sch. No. 807(e) (40 Amp. TPN) |
| 10 | )Fabrication,Supply & Fixxing of work information board in M.S frame made by 50 mm dia sqaure pipe of stainless steel grade SS-304 &16 mm thick base plate with back supporting of bracing by MS flat of 25x6 mm and 2.85 Mtr. Long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green colour with white letters as required and shall be fixed at a height of 1.2 Mtr. from ground by providing 0.45x0.45x0.60 Mtr. cement concrete stone pad complete in all respect. |
| 11 | ( UPPWD Sch. No.504(d) )Supply and fixing of plain or pin type copper tin plated cable socket to the cable leads ,insulated with tape and making connection etc complete in all respect as per direction of the Engineer in charge. 16 Sqmm |
| 12 | ( UPPWD Sch. No. 504(f))Supply and fixing of plain or pin type copper tin plated cable socket to the cable leads ,insulated with tape and making connection etc complete in all respect as per direction of the Engineer in charge.35 sqmm |
| 13 | ( PWD Sch. 501© -507)Supply & laying 16 sq mm 2 core Al. conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a dwc pipe/hdpe/hume pipe as per instruction of engineer incharge. On surface the cable run shall be fixed on MS clamps of suitable size or as directed by Engineer in-charge. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per (Polycab /KEI/ Havells/ Grandlay/gloster Make) |
| 14 | ( PWD Sch. 501(k)-507)Supply & laying 35sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a dwc pipe/hdpe/hume pipe as per instruction of engineer incharge. On surface the cable run shall be fixed on MS clamps of suitable size or as directed by Engineer in-charge. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per (Polycab /KEI/ Havells/ Grandlay/Gloster Make) |
| 15 | Supply, installation, testing and commissioning of Chemical Earthing for panel. |
| 16 | Supply and laying of 25 mm X 3 mm G.I Strip from earth electrode directly in the ground as required complete in all respect. |
| 17 | S/F of MS Earthing Rod (2500*20 mm) in verticaly ground level and connecting the pole with help of 6 SWG Wire including cost of all material men and T&P as per |
| 18 | (DSR 14.1.2.3)Supplying and laying of following size DWC pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD- 63 mm & ID-51 mm nominal) (as per UPPWD approved make list) |
| 19 | Supply, sagging, jointing and binding of insulated ACSR Weasel conductor including cost of aluminium tape binding and jointing sleaves etc. complete in all respect rate |
| 20 | AMC Charges for maintenance ,proper watch and ward of entire electrical system of Street Light and High Mast Tower,cables,conductors,poles,panels etc and all other available material as per direction of engineer in charge for road lightng in IA to cover the general supervision for execution of work including dismantling and re fixing of all street light of UPSIDA during the period of AMC for 12 months (01 Electrican and 01 Helper) as per complete. |
| 21 | Dismantling & re-grouting of Street liht 12 Tilt/sick bend/STP pole in 1:3:6 ratio cement concrete with stone pad including stranthening of pole by providing additional 04 nnos. Support of 65X65X6mm or higher size MS angle in suitable length with the help of welding/cutting . |
| 22 | Lowering / Lifting of 30/16/12.5 Mtr. High mast lighting system complete in T&P men & material required proper completion of work etc. |
| 23 | S/F of Trailing Cable for High Mast lighting system complete including all T&P men and material required for proper completion of work . |
| 24 | S/Oiling of winch machine for High Mast lighting system complete including all T&P men and material required for proper completion of work . |
| 25 | Supply & Fixing of Male-Femal plug & socket for Hight Mast lighting system complete including all T&P men material required for proper completion of work as complete in all respect. |
| 26 | Painting of S.T.poles and all mountings on it with two coats of aluminium paint with an under coat of red oxide paint on length of the up to 10 m support above the ground level or as per direction of Engineer in charge of work/site including all T&P,men & material for proper completion of work |
| 27 | Painting letters (Pole no.) 2.5 cm upto 8.0 cm size complete on street light pole/panel/other electrical properties under UPSIDA including cost of all material men and T&P complete in all respect as per complete. |
| 28 | (UPPWD (2018)1002)S/F of 6 Amp.To 32 Amp. SP MCB (10KA) C curve Cat-B complete in all respect.. |
| 29 | (UPPWD (2018) 1020)S/F of 63 Amp. 4Pole MCB (10KA) C curve Cat-B complete in all respect.. |
| 30 | ( UPPWD (2018) 1128 (c))S/F of heavy duty cadmium plated copper connector with end plate complete in all respects (c) four way connector HKM 100 as per complete. |
| 31 | S/F of ML-4 contactor MDS/L&T make complete including all T&P man and material required for proper completion of work as per complete. |
| 32 | S/F of mounting time switch (timer clock) L&T/MDS make complete including all T&P men and material required for proper completion of work as per complete |
| 33 | (UPPWD (2018) 289(P))Supply and wiring of sub main with 03 nos.of 2.5 sq. mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of work as directed E/I as per |
| 34 | Supply and wiring of (3CX1.5sqmm copper wire) for High Mast Lighting system complete including all T&P men and material required for proper completion of work as per directed by Engineer I/C. |
| 35 | Supplying and wiring of 4sq.mm aluminium conductor PVC insulated unsheathed single core cable including all T&P men and material required for proper completion of work as per directed by Engineer I/C. |
| 36 | (UPPWD (2018) 1423)Dismantaling & Re- Fixing of LED Street Light complete in all respect |
| 37 | (UPPWD (2018) 501(j) )Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properlyconnected with the earth conductor by clamps etc. 3.5X25Sqmm |
| 38 | (UPPWD (2018) 503(j) )Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 3.5X25Sqmm |
| 39 | (UPPWD (2018) 504(e) )Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 25Sqmm |
| 40 | (UPPWD 2018 621)Supply & fixing of 100 mm x 110 mm shackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect. |
| 41 | (UPPWD 2018 315)Supply & Fixing of 32 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. CAT B |
| 42 | (UPPWD 2018 316)Supply & Fixing of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. CAT B |
| 43 | Supply & fixing of driver suitable for (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect . |
| 44 | Supply & fixing of MCPCB with LED & Lance (110 to 130 watt) / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect .(1st year =50%, 2nd year=25%, 3rd year=25%) |
| 45 | Supply & Fixing of Glass suitable for installed (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect. (1st year =50%, 2nd year=25%, 3rd year=25%) |
| 46 | Supply & fixing of LDR suitable for installed (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect . |
| 47 | Supply & fixing of special protection device (SPD) suitable for (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect . |
| 48 | Cost of all material, spares wire fuses,small accessories required for general maint.,cleaning,oiling etc.to keep the entire installation in perfect working order during AMC period complete in all respect. as per complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender