Tender for Rewiring To The Dormitories (2 Nos) At Eco Tourism Site At Bondla Wildlife Sanctuary In Valpoi Constituency.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch modular plates suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.;(a) Group A -- with Cat A Modular Accessories |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit) |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(d) 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm Conduit) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(e) 2 x 10 sq.mm + 1 x 10 sq.mm earthwire (25mm Conduit) |
| 6 | Wiring for 5A /15A power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 7 | Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity modular plate and cover including connection painting etc. as required.;(a) Cat A |
| 8 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.;(b) Cat B |
| 9 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(a) Cat A |
| 10 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required;(a) Cat A |
| 11 | Supplying and fixing following size modular GI box alongwith modular base and cover plate for modulator switches in recess etc. as required;(a) 1 or 2 Module ( 75 mm x 75 mm) Cat A |
| 12 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(a) Cat A |
| 13 | Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 14 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(a) Cat A |
| 15 | Supply and erecting S type Stainless Steel fan hook fabricated out of 10 mm round bar complete as required. |
| 16 | Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge including painting etc as required |
| 17 | Supplying and fixing following way TPN sheet steel double door Verticle type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required);(a) 4 way (8+12) double door Vertical type Cat A |
| 18 | Supplying and fixing following way SPN sheet steel MCB distribution board Consumer Unit 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar hinged front acrylic cover for the MCB knobs detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(c) 2 + 12 way Cat A |
| 19 | Supplying and fixing following rating four pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(a) 40 A Cat A |
| 20 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 21 | Supplying and fixing 40 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(c) DP Cat A |
| 22 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(b) In rocky strata |
| 23 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 24 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 25 | Supply Installation Testing & Commissioning of of Round Ceilling Mounted Surface LED light fixture as required of make Bjaja model no.GLINT PRO 24WWWRRD PD or Equivalent in similar pattern in recognised ISO certified brands only & to be approved by the Engineer in charge. |
| 26 | Installation earthing testing and commissioning of exhaust fan upto 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connections testing commissioning etc as required |
| 27 | Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings 1400 rpm complete with all accessories.;(a) Cat A |
| 28 | Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 16 sq.mm |
| 29 | Supply of 3 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 4 sq.mm |
| 30 | Supply of 3 core unarmoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 2.5 sq.mm |
| 31 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.;(b) In rocky strata |
| 32 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required |
| 33 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.;(2) 3 x 4 Sq. mm. |
| 34 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.;(1) 3 x 1.5/2.5 Sq. mm. |
| 35 | Supplying and fixing DK thermoplastic Cable Junction Boxes130 x 130 x 77mm IP 66/69 weather proof for outdoor installation (with knockouts for cable entry) including connections etc & inbuilt 4 way stud type connectors of make Hensel cat no. DK 0604 G / spelberg and fixing of 32 mm dia Gi pipe including, clamps nut bolts, cement, sand, excavation for mounting etc. as required. |
| 36 | Supplying and fixing call bell/ buzzer suitable for single phase 230 V complete as required.;(a) Ding Dong Bell |
| 37 | SITC of 4Mtr length octagonal hot dip galvanised pole, with top dia of 70mm, having 3mm sheet section thickness alongwith base plate of size 220x 220x12mm (LxBxT), including J-type M16 x450 MM foundation bolts set along with required tamplate, a Smart pack junction box shall be provided with 1no 6A MCB on DIN rail and 4pole red strip connector /terminal block (60Arating) suitably enclosed with watertight door with locking arrangement, mounted flushed inside base compartment, having suitable entry for drawing two or more cables upto 16sqmm. The poles shall be of make: Consul, RR ipat, or equvivalent in Bajaj, Jaquar, Suncity, phillips, crompton or any other ISO Certified brand etc. as per directions of the Engineer incharge. Transporation from factory to site is inclusive. |
| 38 | Supply and Fixing of Single arm bracket of 1m Standard length, of appropriate dia suitable for 4mtr or 6Mtr hieght poles for top section (70mm) of make: Consul, RR ipat, or equvivalent in Bajaj, Jaquar, Suncity, phillips, crompton or any other ISO Certified brand etc. as per directions of the Engineer incharge. Transporation from factory to site is inclusive. |
| 39 | Supply, installation, testing and commissioning of 36 watts or more LED Street light in Pressure die cast aluminium housing with polycarbonate cover having IP 65 class of protection or above having efficient hight output LED of make Greatwhite bearing cat No.LED-STL-38005, or Jaguar fittings bearing cat NoLSRT01S036XC or Bajaj bearing cat No. BRTFG 36W LED or any approved equivalent make ( to be approved by Engineer in Charge) complete with 40 mm dia GI pipe bend at an appropriate angle of length 80cms and having three years free replacement warranty complete as required. |
| 40 | Supplying and fixing of LED Bollard light fitting 9/10W along with its accessories and fittments including bulb, pc diffuser etc. ip 65 protected, as required of make bajaj model BGBOM 605 9W LED WH or Havells Model NTBL 10W LED830PSYMTOPMMA or Equivalent, to be approved by Engineer in charge. |
| 41 | S.I.T.C of LED Gate / Compound light Fitting 25W or above along with its accessories and fittment / mounting the same as per required site conditions with proper finishing etc, of make Jaquar model LGTP06XO40XW / Crompton Model CBP-610-25-57-SL-CA-NBK/ Bajaj Model GLATT MT 60L WH PO PC SD or Equivalent in recognised / ISO certified brands only & to be approved by Engineer in charge. |
| 42 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.;All kinds of soil;All types of Ordinary rock including all types of laterite rock blasting prohibited |
| 43 | Providing and laying cement concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded granitic a basaltic stone aggregate 40 mm nominal size) excluding cost of centering shuttering and finishing in;All works upto plinth level |
| 44 | Providing TMT steel reinforcement bars of (SAIL TATA. VIZAG JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 45 | Supply Installation Testing and Commissioning of Cordless type, high wall split type air conditioner of 1.5 TR capacity & 5 star rating having in built time delay features, Auto start facility, three speed cooling capacity, Oscillating louvers with scroll compressor suitable for operation on single phase 230 volts, 50 Hz A.C. supply of make Panasonic Model CU/CS-EUI8AKY5 or equivalent in Voltas/Daikin/Mitsubishi/ Bluestar make as approved by the Engineer in Charge. |
| 46 | \\"Supply and fixing of 5 KVA automatic voltage stabilizer for 1.5ton/2 ton Air Conditioner unit as required of make Everest/V-Guard\\" |
| 47 | Supply and fixing of M.S. stand to install 1/1.5 /2.0 Ton condening unit with suitable screws etc as required for Split AC. |
| 48 | Supply and fixing of Refrigerent copper piping of suitable size with insulation as required for Split AC. |
| 49 | Supplying and fixing of PVC drain piping of suitable size as per site of approved make. |
| 50 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.;(b) 25 mm |
| 51 | Supplying and fixing of following sizes of PVC casing caping alongwith accessories on surface as required.;(b)25mm casing capping |
| 52 | Dismantling, removal & stacking of old wiring including removal of wires , cable ,DB's, down rods, Switch Boards fittings / fixures etc Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender