Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #56404513

Tender For Providing Installing Testing Commissioning And Handing Over Of Ahu/ Fcu And Other Allied Works For Female Surgical Ward, Area-33 Of Level-Iii, Block A, Gmch, Sector - 32 Chandigarh.

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
17.20 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
0 days left
EMD
34410
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Installing Testing Commissioning And Handing Over Of Ahu/ Fcu And Other Allied Works For Female Surgical Ward, Area-33 Of Level-Iii, Block A, Gmch, Sector - 32 Chandigarh.

BOQ

Name of Work:- Providing Installing Testing Commissioning and Handing Over of AHU/ FCU and other allied works for Female Surgical Ward, Area-33 of Level-III, Block A, GMCH, Sector - 32 Chandigarh.
Sl. No. Item Description
1Supplying, Installing, Testing and Commissioning of Factory Built Floor Mounted Chilled Water Double Skin Type Air Handling Units made of 40 mm thick panels consisting of G.I. Casing of thickness 0.6mm outside layer, 0.6mm thickness inside layer with polyurethene foam (PUF) insulation of density not less than 38 Kg/Cum factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as detailed below. Cooling Coil section with aluminium finned copper tubes (Tube thickness not less than 0.5mm) cooling coil, filter section with 50mm thick metal, washable synthetic Type Pre Filter, Fine Filter, belt drive package with TEFC Drive Motor suitable for 415+ 10% Volts, 50 Hz, 3 Phase, A.C. Supply, complete drain connections, stainless steel drain pan complete in all respect to the entire satisfaction of EIC.
2The drain pan shall be of 18 Guage stainless steel with necessary slope to facilitate fast removal of condensate water. The water header shall be of copper with water in and out connections, vent plug on top and drain at bottom.
3Make: Edgetech/ Systemair/Zeco/ WavesMake of Blower : Kruger/Nicotra/Comefree Make of motor: Havells/Crompton/Siemens/ABBMake of filter: Thermadyne/ Camfil/ Enfilco
4AHU/ 11000 CFM/ 120mm Static/ 6 Row Coil/ 27.5TR
5Supply, installation, testing and commissioning of Fan Coil Unit, each complete with 3 rows deep chilled water coil, centrifugal fans, cleanable fabric filters, main condensate drain pans, auxiliary drain pan, complete with insulation of required thinkness, as described in specifications, casing, coil piping connections, wiring, control wiring in conduit upto themostat boxes. All fan coil units shall be suitable for 220 + 6% volts, 50 cycles, single phase power supply. including cost of motor opening in wall & make good same in original condition Fan Coil Units shall be of following refrigeration capactites as listed.Make : Edgetech/ System Air/ Zeco
62.0 TR Nominal Capacity
7Supply, installation, testing and commissioning of controls for fan coil units consisting of 2-way motorized spring return valves, Snap acting type heating/cooling thermostat with fan speed switch, wiring etc. inculding cost of removing old one, from site, cleaning of area, fixing of new one inculding cost of all T&P and other arrangement /Material requied for fixing of 2-way valve , insulation of valve & pipe where required, with approved make insulation material,PVC conduet pipe, wires, shocket etc. complete job as per satisfactions of EIC. Make Honeyweel/ Siemens/ Belimo/ Danfoss
825 mm dia valve
9SITC of Ball valves set with and without Y-Strainer duly insulated as per specifications. Make: Sant/ Emerald/ Leader/ Rapid cool
1025 mm dia Valves
11Supply, installation, testing and commissioning of 2-way motorized valves suitable for Chilled water as well as hot water application complete with Electrical / Electronic actuator, necessary wiring and required accessories for proper operation and control of valves of following sizes. Make: Honeywell/ Siemens/ Belimo/ Danfoss
1265 mm dia
13Supply, installation, testing and commissioning of cooling / heating thermostats for various Air Handling Units as per specifications including all accessories, mountings, wiring between thermostat & unit, terminations etc., complete in all respect as required and as per specifications. Make: Honeywell/Siemens/Belimo/Danfoss
14Proportional Thermostats for Air Handling Units
15Providing and fixing in position the industrial type pressure gauges with Syphen and gun metal ball valves. :Make H-Guru, Febig
16Providing and fixing of 6\\" Stem Type Thermometers (0 To +50ºC) complete as per site requirment. Make H-Guru, Febig
17Supply and fixing of UL approved thermal insulation on A C ducts with 13 mm thick closed cell EPDM insulation including providing adhesive, adhesive tapes etc. as per specifications (with GC coatting).Make:- Armacell/ Aflex/ Kflex
18Supply, installation and testing of acoustic lining with 15 mm thick Nitrile foam class O accoustic insulation icluding Anti Microbial coating providing adhesive, adhesive tapes etc.as per the specifications. Make:- Armacell/ Aerofoam /Kflex
19Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas sleeve as per the approved shop drawings. For AHU/ FCU as per site requirement.
20Supply, installation and testing of GI construction Louver dampers within ducts to be provided with suitable ducts lever and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system. Make:Caryaire/Systemair/Airflow
21Supplying & fixing of opposed blade aluminium construction volume control dampers in supply air duct collars as per approved drawings and specifications. Make: Caryaire/ Systemair/ Airflow
22Supply, installation, testing and balancing of powder coated extruded aluminum square shape return air diffusers with removable core and anti smudge ring & aluminum volume control dampers as per specifications. Make: SystemAir/ Caryaire/ Airflow
23Providing and fixing in position the following PVC (Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 13 mm thick insulationas per specifications. Make: Finolex/ Supreme/ Adhunik/ Diplast/ Prince
2425 mm dia pipes
25Control AHU Panel : (LDB)
26Design, Manufacure, Supply, Installation, Testing and Commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCB and earthing in each panel.
27All Starters shall have the following accessores:-
28TPN MPCB/ MCB as per the suitable rating, terminal block for power distribution, contactor, overload realy with built in single phasing protection, phase indication lights and indicating light for ON/ OFF Status, Ammeter with CTs and Selcter Switches, Relay, Auto Manual Selection & Push Buttons with SP MCB.
29The number of Control Panels shall be as follows.
30HVAC AHU Panel with Exhaust AHU along with VFD
31Incoming
321 No. 125 Amp MCCB TP 50 KA with Rotary Mechanism and Spreader links.
33Phase indicating lights with control fuses.
34Breaker ON/OFF/TRIP indicating lights.
35Bus Bars
3680 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.
37100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
3801 No. Voltmeter of range 0-500V, selector switch and 2 Amps SP MCB back up.
3901 No. Ammeter Digital of range 0-40 A, selector switch and 3 Nos. of associated CT's of ratio 63/5 A.
40Outgoings
413 Nos TP MPCB, 25-32 A with DOL starter for AHU Motor Panel with all control wiring, contactor, relay, timer, single phase preventer, on/off switch, indicator complete as per requirement and satisfaction of EIC.
422 Nos. 10 amps DP MCB (single Phase) with step down transformer 220V to 24V (AC)
43Phase indicating lights with control fuses.
44Breaker ON/OFF/TRIP indicating lights.
45Each outgoing shall have auto / manual selector switch, indication lamps with control MCB's, ON/OFF push buttons, necessary internal control and power wiring in all respect. .The panel shall have necessary contactors / ancillaries for BMS operation and fire signal. Spare space for any future provision be made by the agency in electrical panel.
46Panel as described above and in drawings.
47Panel Make: Adlec/ Siemens/ Tricolite/ Unitech Power System/ Vrindavan Electricals.
48Power & Control Works
49Supplying and laying of following 1100 volt grade PVC insulated sheathed copper/ aluminium conductor armoured cables in trenches, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging brick and sand protection, and including jointing/ connecting/ terminating, testing and commissioning : Make: Havells/ Ecko/ Finolex/ Polycab.
504.0 Core x 6 Sqmm A.I. Armoured
514.0 Core x 4 Sqmm CU. Armoured
52Supplying, installation, testing and commissioning of control cabling with insulated PVC sheathed wire/cable as per IS-7098 (Part-1) of following sizes including terminations on suitable cable trays / uPVC pipe with supports, as required including connections on both sides as per specifications and as required. Make: Havells/ Finolex/ Polycab/ Ecko ISI Marked
534 core x 1.5 sq. mm.
54DSR (E&M) 2025 Items
55Hot Dipped Galvanized Iron Cable Tray
56Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
57100 mm width X 50 mm depth X 1.6 mm thickness
58Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
59Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.
60Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
6180mm dia. (50mm thick insulation)
6265mm dia.(50mm thick insulation)
6350mm dia.((50mm thick insulation)
6425 mm dia (50mm thick insulation)
65Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.
66BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
6780 mm dia.
6865 mm dia.
69BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified
7065 mm dia
71Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
7265 mm dia
73DUCTING, GRILLS,DIFFUSER AND INSULATION
74Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required
75Thickness 0.63 mm sheet
76Thickness 0.80 mm sheet
77Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required.
78Supplying, Fixing, testing and commissioning of fire dampers of minimum 90 minutes fire rated in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required
79Fire damper
80Actuator
81DSR (Civil) 2023 Items
82Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
8312.5 mm thick tapered edge gypsum moisture resistant board
84Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
85New work (two or more coats) over and including water thinnable priming coat with cement primer
86Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
87Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
8825 mm nominal bore
89Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.
90Pre-laminated particle board with decorative lamination on both sides Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56404513
AUTHORITY Local Bodies
TENDER VALUE 17.20 Lakhs
LAST DATE 15-07-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Providing Installing Testing Commissioning And Handing Over Of Ahu/ Fcu And Other Allied Works For Female Surgical Ward, Area-33 Of Level-Iii, Block A, Gmch, Sector - 32 Chandigarh.
Basic Detail
Tender No PH1/2026/426
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 10 Jul 2026
Submission Date 15 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value 17.20 Lakhs
Tender Fee Ref. Documents
EMD 34410
Exemption Not Available
Document List
BOQ_115124.xls
c047f18f-c002-4b3a-9100-7748e363f2d5.html
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_115124.xls

html

c047f18f-c002-4b3a-9100-7748e363f2d5.html

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders