Tender For Periodical Services To Overhead Water Tanks Under Age (I) (U) B/R Delhi Cantt - 10
Tender Overview
Project Description
Tender for Periodical Services To Overhead Water Tanks Under Age (I) (U) B/R Delhi Cantt - 10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jul-2026 | Revised Dates | Date | 10-Aug-2026 |
| 2 | 10-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : AGE(I)(U)(B/R) Delhi Cantt-10 Name of Work : PERIODICAL SERVICES TO OVERHEAD WATER TANKS UNDER AGE (I) (U) B/R DELHI CANTT - 10 Contract No : AGE (I) (U) B/R-Token-18/2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. by skilled labour RCC over head reservoirs & high rise structures exceeding 10 mtr height but not exceeding 20 mtr height from ground level including necessary scaffolding complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for applying two coats of weather proof exterior emulsion paint on old surface RCC over head reservoirs & high rise structures exceeding 10 mtr height but not exceeding 20 mtr height from ground level including necessary scaffolding using brush for 1st coat and 2nd/ final coat with Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for applying two coats of weather proof exterior emulsion paint over priming coat of exterior primer on new or untreated plastered surfaces RCC over head reservoirs & high rise structures exceeding 10 mtr height but not exceeding 20 mtr height from ground level including necessary scaffolding using brush for priming coat and 1st coat and 2nd/ final coat with Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for repairing of chajja / roof projection by taking down old plaster, damaged concrete surface,cutting of exposed reinforcement and making good with 1:4 including admixture of SBR (cost of SBR including) as per manufacturer, and provide reinforcement cement concrete 1:2:4 type B1 as required, necessary scaffolding,formwork etc up to 20 Mtr height and applying 10 mm thick rendering in cement mortar 1:3 including providing chicken mesh wire netting where necessiaty , finishing the surface even & smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 7 | Taking down cement plaster in cement or cement lime mortar on brick, RCC, stone walls & RCC over head rservoirs & high rise structures exceeding 10 mtr height but not exceeding 20 mtr height from ground level including necessary scaffolding including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to out side MS land complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for 15 mm thick rendering in cement mortar 1:4 on other than fair face of brick work /concrete surfaces/ PCC block/stone masonry wall surface, RCC over head reservoirs & high rise structures exceeding 10 mtr height but not exceeding 20 mtr height from ground level including necessary scaffolding including mixing liquid water proofing compound as per manufacturers instructions, finished the surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.Note:- WPC will be measured & paid separately |
| 9 | M&L for guniting with cement coarse sand 1:3 with and including water proofing bonding agent of FOSROC/SIKA/Pidilite @ 1 ltr per 50 kgs of cement and water cement ratio 0.45 used as per manufacturer's instruction using shotcrete pumps and allied equipment, uniform thickness 30mm to 50mm including 15 mm thick plaster in cement mortar (1:4) uniform and smooth finished upto height of 20 mtr from ground level complete all as specified and directed by Engineer-in-Charge.Note- (a) Quoted rate shall be inclusive of material, all kind of labours, tools and plants, scaffolding and working upto 20 mtr height mentioned in respective items of work from ground level. (b) Adoption of necessary safety arrangement like safety belt, ropes, helmets, safety net etc. which are required for labours working at height of 3 mtr and above from ground level and all rate shall be mandatory and deemed to be inclusive in quoted rates. |
| 10 | Supply and fixing hard drawn steel wire fabric weight not exc 4 kgs/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, fixed with existing reinforcement work upto height of 20mtr from ground level complete all as specified and directed by Engineer-in-Charge.Note- (a) Quoted rate shall be inclusive of material, all kind of labours, tools and plants, scaffolding and working upto 20 mtr height mentioned in respective items of work from ground level. (b) Adoption of necessary safety arrangement like safety belt, ropes, helmets, safety net etc. which are required for labours working at height of 3 mtr and above from ground level and all rate shall be mandatory and deemed to be inclusive in quoted rates. |
| 11 | Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender