Tender For special Repair Of Lt Overhead Acsr Conductor To Underground Cable At Baramulla And Pattan Under Ge 969 Ews
Tender Value
48.52 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
17 days left
EMD
97040
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Lt Overhead Acsr Conductor To Underground Cable At Baramulla And Pattan Under Ge 969 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of cross arms of MS channel or angle sections etc, complete all as specified and as directed. |
| 2 | Dismantling HT/LT OH line from the insulators, complete all as specified and as directed. |
| 3 | Dismantling and taking down the existing LT/HT insulators of any type from any description, complete all as specified and as directed. |
| 4 | Dismantling & Taking out the existing old service cables off sizes, complete all as specified and as directed. |
| 5 | Dismantling old UNSV existing LT panel with switch gears, complete all as specified and as directed. |
| 6 | Dismantling & Taking out old UNSV earthing, complete all as specified and as directed. |
| 7 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified and as directed. |
| 8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core , complete all as specified and as directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core , complete all as specified and as directed. |
| 10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core, complete all as specified and as directed. |
| 11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core , complete all as specified and as directed. |
| 12 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core. (For Security Lt Pole) |
| 13 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sq mm 3.5 core.(Existing Panel Sig Det to FOL Area ) |
| 14 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core , complete all as specified and as directed. |
| 15 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 50 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil, complete all as specified and as directed. |
| 16 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed. |
| 17 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm, complete all as specified and as directed. |
| 18 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable, complete all as specified and as directed. |
| 19 | M&L for Sub class \\"B\\" bricks laid dry width wise across the line of cable in treanchs as cable protection, complete all as specified and as directed. |
| 20 | S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :- |
| 21 | (a) 50 mm dia |
| 22 | (b) 80 mm dia |
| 23 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :- |
| 24 | (a) INCOMING |
| 25 | (i) MCCB 4 Pole 415 volts grade 315 Amps rating and 36 KA rupturing capacity - 01 No |
| 26 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 27 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 28 | (iv) CTs ratio 400/5A class ISI marked sets of three each |
| 29 | (v) Indicating lamp-01 set of three |
| 30 | (b) OUTGOING |
| 31 | Outgoing MCCB 250 Amps 4 pole, 415 V 25 KA-02 Nos |
| 32 | Outgoing MCCB 63 Amps 4 pole, 415 V 25 KA-01 Nos |
| 33 | Outgoing MCB 40-63 Amps Douple Pole, 240/415 V -06 Nos |
| 34 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-( Mahadev Enclave ) |
| 35 | (a) INCOMING |
| 36 | (i) MCCB 4 Pole 415 volts grade 250 Amps rating and 36 KA rupturing capacity - 01 No |
| 37 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 38 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 39 | (iv) CTs ratio 400/5A class ISI marked sets of three each |
| 40 | (v) Indicating lamp-01 set of three |
| 41 | (vi) On load Change Over Switch 200 Amp 415 V -01 |
| 42 | (b) OUTGOING |
| 43 | MCCB 4 pole, 100 Amps,415 V 36 KA-04 nos |
| 44 | Outgoing MCB 63 Amps DP , 415 V 16 KA-03 nos |
| 45 | Outgoing MCB 40 Amps DP , 415 V 16 KA-03 nos |
| 46 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-( Alfa Mess ) |
| 47 | (a) INCOMING |
| 48 | (i) MCCB 4 Pole 415 volts grade 250 Amps rating and 36 KA rupturing capacity - 01 No |
| 49 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 50 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 51 | (iv) CTs ratio 400/5A class ISI marked sets of three each |
| 52 | (v) Indicating lamp-01 set of three |
| 53 | (b) OUTGOING |
| 54 | Outgoing MCCB 250 Amps 4 pole, 415 V 36 KA-01 nos |
| 55 | Outgoing MCB 63 Amps DP , 415 V 16 KA-08 nos |
| 56 | Outgoing MCB 40 Amps DP , 415 V 16 KA-08 nos |
| 57 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-( Alfa Mess ) |
| 58 | (a) INCOMING |
| 59 | (i) MCCB 4 Pole 415 volts grade 100 Amps rating and 36 KA rupturing capacity - 01 No |
| 60 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 61 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 62 | (iv) CTs ratio 400/5A class ISI marked sets of three each |
| 63 | (v) Indicating lamp-01 set of three |
| 64 | (b) OUTGOING |
| 65 | Outgoing MCCB 63 Amps 4 pole, 415 V 16 KA-01 nos |
| 66 | Outgoing MCB 63 Amps DP , 415 V 16 KA-04 nos |
| 67 | Outgoing MCB 40 Amps DP , 415 V 16 KA-04 nos |
| 68 | Supply, install, testing and commissioning of LT feeder piller box outdoor type made out of 3.15 mm thick CRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 400 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accomodate the following accessories. (Feeder Pillar near PH) |
| 69 | Incomer:100 Amp, 4 pole MCCB, 36 KA 415V - 01 No,Digital Volt meter 0-500V with inbuilt selector switch - 01 No Digital Amp meter 0-500A with inbuilt selector switch & CT Coils- 01 NoSet of LED type indicating lamps - 03 No Aluminium Bus Bar 100 Amp TPN OutgoingMCB MCCB 40 AMP Outgoing -02 NOs Please Enable Macros to View BoQ information |
| 70 | Incomer:100 Amp, 4 pole MCCB, 36 KA 415V - 01 No,Digital Volt meter 0-500V with inbuilt selector switch - 01 No Digital Amp meter 0-500A with inbuilt selector switch & CT Coils- 01 NoSet of LED type indicating lamps - 03 No Aluminium Bus Bar 100 Amp TPN OutgoingMCB MCCB 40 AMP Outgoing -02 NOs Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST