Tender for Augmentation Of Electrical Distribution System And Maintenance Of Electrical System At Barc Hospital And Ct&Crs Building, Anushaktinagar, Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Day-to-day maintenance of various electrical distribution system at BARC Hospital & CT&CRS Building as per clause no. 1 of technical specification. |
| 2 | Round the clock operation of electrical system at BARC Hospital as per clause no.2 of technical specification. |
| 3 | Supply, installation, testing & commissioing of 5.5 Kw, 415V, IP20 at new BARC Hospital after removal of faulty VFD as per clause no.3 of technical specifications. |
| 4 | Supply, installation, testing & commissioing of 11Kw, IP 20, 415V, IP20 at new BARC Hospital after removal of faulty VFD as per clause no.4 of technical specifications. |
| 5 | Supply, installation, testing and commissioning of following fan regulators/capacitors as per clause no.5 of technical specifications |
| 6 | Ceiling fan regulator 120W 2 module |
| 7 | Knob of Ceiling fan regulator |
| 8 | 1.2mfd capacitor for exhaust fans |
| 9 | 2.5mfd, 400V MPP type capacitor for ceiling fans |
| 10 | 4mfd, 400V MPP type capacitor for exhaust fans |
| 11 | Supply, installation, testing and commissioning of MCBs as per clause no.6 of technical specification |
| 12 | 32A FP MCB |
| 13 | 16A,DP,MCB |
| 14 | 32A,DP,MCB |
| 15 | Supply and installation of Heavy duty tube terminal type copper lugs for following sizes of wires/cables as per cclause no.7 of technical specification |
| 16 | Up to 4 sq.mm reducer type |
| 17 | 6sq.mm/10 sq.mm reducer type |
| 18 | 6sq.mm/10 sq.mm Heavy duty tube terminal type |
| 19 | 16sq.mm/25sq.mm reducer type |
| 20 | Up to 10/16 sq.mm copper ferrule |
| 21 | Supply and installation of G.I Fixing fasteners as per clause no.8 of technical specification |
| 22 | Coach Screw 3/8” x 3” long |
| 23 | Anchor Fastener 3/8” x 3” long |
| 24 | Anchor Fastener 1/4” x 2” long |
| 25 | Supply, installation, testing and commissioning of cooling fan of VFDs as per clause no.9 of technical specification |
| 26 | Supply and installation of following spares as per clause no.10 of technical specification |
| 27 | Panel knob with key for Legrand DB. |
| 28 | Panel lock |
| 29 | Preventive maintenance of fire alarm system at CT&CRS building as per clause no.11 of technical specifications. |
| 30 | Supply ,installation, testing & commissioning of addressable multi sensor smoke detector as per clause no.12 of technical specification |
| 31 | Supply ,installation, testing & commissioning of intelligent addressable manual call point as per clause no.13 of technical specification |
| 32 | Supply, installation, testing & commissioning of hooter cum strobe along with appropriate base module as per clause no.14 of technical specification |
| 33 | Supply ,installation, testing & commissioning of response indicator as per clause no.15 of technical specification |
| 34 | Supply ,installation, testing & commissioning of fire alarm wiring with 2R x 1.5 sq.mm stranded copper conductor FRLS grade PVC Wire as per clause no.16 of technical specification |
| 35 | Supply and installation of GI Flexible pipe as per clause no.17 of technical specifications. |
| 36 | Supply and installation of 25 mmx 12 mm size PVC casing capping sas per clause no.18 of technical specification |
| 37 | Supply and installation of 25mm dia G.I flexible conduit with adaptor as per clause no.19 of technical specification |
| 38 | Supply and installation of 25 mm dia PVC Conduit as per clause no.20 of technical specifications |
| 39 | Supply and installation of PVC square box for fixing ceiling rose / tube light fixture as per clause no.21 of technical specification |
| 40 | Supply and installation of 5\\" dia. PVC round plate as per clause no.22 of technical specification Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender