Tender for Construction Of Embryo Transfer Technology Laboratory At Haripora Ganderbal.

BOQ

Name of Work:- Construction of Embryo Transfer Technology Laboratory at Haripora Ganderbal.
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
2P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete.
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
4Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete.
5Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete
6Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete.
7Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete.
8Centering and shuttering of Kit-Ply/Steel Plates including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns etc. for mass concrete complete.
9Centering and shuttering of Kit-Ply/Steel Plates including strutting, propping etc. and removal of form work for: Lintel, beams, plinth beams, girders, bressumers and cantilevers complete
10Centering and shuttering of Kit-Ply/Steel Plates including strutting, propping etc. and removal of form work for: Columns, pillars, piers, abutments, posts and struts complete
11Centering and shuttering of Kit-Ply/Steel Plates including strutting, propping etc. and removal of form work for: Edges of slabs and breaks in floors and walls etc complete
12Centering and shuttering of Kit-Ply/Steel Plates including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms.
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
14Supply & laying of Khak Bajree under floors in trenches, plinth, sides of foundations etc consolidating each layer by ramming ,watering, compacting, all inclusive leads, lifts, loading, un-loading, cost and carriage of material all complete.
15Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
16Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level all complete.
17Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) all complete.
1812mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) all complete.
19Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) all complete.
20Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick all complete.
21Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate incl. all complete.
22Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) all complete.Payment shall be made as per actual measurement.
23Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work incl. Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface.
24Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
25Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Welded incl. scaffolding.
26Providing and fixing of high Rib colour coated sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick incl. Ridges, hips, Valleys etc all complete.
27Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank all complete.
28Providing and fixing of PVC fittings for PVC pipes of approved quality and make( prince B type). Pipe 100mm dia
29Pipe 75mm dia
30100mm Floor Trap
31Door Junction 75mm
32Door Tee 100mm
33Providing and fixing of C.P fittingsof standard quality and make incl. all necessary fittings/fixtures all complete. 15mm Angle Valve
3415mm Bib Cock
35Wall Mixer
36Sink Mixer
37Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm
38Wash Basin Mixer
39CP Connection
40Stainless Steel Soap case
41Providing and fixing 50 liter capacity water heater Gyser of approved brand of jaquar/Venus/ Recold or any equivalent brand including its fixing at desired position complete in all respects.
42Stainless Steel Towel Rod
43Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc 15mm nominal bore
4425mm nominal bore
4520mm nominal bore
4640mm nominal bore
47Stop Cock
48Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown including all carriages.
49Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
50Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IsS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm all complete.
51Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-In-Charge 18 mm thick.
52Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm &sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
53Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).
54Carriage of Material:- Sand/Stone agg. For an avg. lead of 10 Kms.
55Bricks for an avg. lead of 50 Kms
56Electric Part
57Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Anchor/Salzer/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work.
58Supplying and Fixing of Indicator as required, ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work.
59Wiring for Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Anchor/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Anti-Bacterial Series of Havells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work.
60Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work.
61Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Anchor/Salzer/Havells Make)
62Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output)
63Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make)
64Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work.
65Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer/Havells Make) & shall be approved before execution of work.
664x10 sq.mm+ 2x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
672x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
682x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards.
692x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards.
70Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/ABB/Equivalent Make
71Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH Make)
72Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH Make)
7325-32Amp.
7440Amp.
7563Amp.
76Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make)
77ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
78Supply and fixing of 18 Watt LED Powder coated Pressure die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2150 lumens .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material.The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Signify (Philips)/Lighting Techonology/Endo/Regent /Trilux /Wipro/Equivalent make.
79Supplying, installation, Testing & Commissioning of 100 Watt (System lumen efficacy ≥120 lm/Watt) Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 lm/Wattoutput . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Surya/Wipro make.
80Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Halonix/Polycab/Orient/Anchor Make.(5-Star)
81Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient/Halonix Make.
82Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
83Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683) suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires.
84Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes.
85Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc.
86Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/Panasonic/Anchor/Schneider/Equivalent Make
87Supply/installation/testing and commissioning of CPRI-approved (IS/IEC:61439) panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:​1. Normal Incoming:160 Amp TPN MCCB with breaking capacity of 36 KA with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,400 Amp Bus bar Al Strips(3+1) = 1 Set, MultiFunctional Meter =1 No., phase indicators =1 set2. Generator Incomer:100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set​3. Bypass Switch:100 Amp 4-Pole Bypass Switch for bypassing 25 KVA AVR​Outgoing:​(1) 100 Amp DP MCB (15-16 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 01 No for 3-Phase Machine.​(2) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 01 No for 3-Phase Machine.​(3) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 03 No for normal heating sub main​(4) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 04 No for Sub main lighting/ACs​(5) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing.
88Supply/Installation/Testing & Commissioning of 1-phase 10 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of AE/Chinar/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-N) ranging from 120 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection.(For Lighting & Machine Points Only)
89Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make.
90Supply/Laying/Testing and Commissioning of 3.5- Core 50 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.(Only required quantity shall be executed)
91Supply and Fixing of Modular 25-32Amp industrial Socket outlet having fitted with 32 Amps DP MCB and Top with Modular Plate,Cover in front & suitable GI box etc for AC Points of Legrand/Siemens/ABB/Schinder Make.
92Supply/Laying/Testing and Commissioning of 3.5 Core 10 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount Make. Including Supply/Laying of HDPE/PVC Pipe of suitable dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. (from Panel to Strelization or OT Room)
93Supply/Fixing/Testing and Commissioning of 63 Amp , 4 pole, (TPN) 440 V, C* Curve 10K, complete with connections Steel Enclosure (L&T/Siemens/ Legrand/ABB/ Schneider Make) (for Strelization or OT Room)
94Supply/Fixing/Testing and Commissioning of 100Amp , 4 pole, (TPN) 440 V, C* Curve 15-16K, complete with connections Steel Enclosure (L&T/Siemens/ Legrand/ABB/ Schneider Make) (for Strelization or OT Room)
95Supply/Laying/Connecting of 6SWG copper solid wire with cotton cover as required in one run fitted with of brass nut bolt & spring washer up to MAIN Control PANEL through PVC Conduit complete job for earthing. (for Strelization or OT Room) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56403573
AUTHORITY Government Departments
TENDER VALUE 1.09 Crore
LAST DATE 16-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Embryo Transfer Technology Laboratory At Haripora Ganderbal.
Basic Detail
Tender No NIT No.32-2026-27
Bidding Type Tender
Location
City Ganderbal
State Jammu and Kashmir
Key Dates
Publish Date 10 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 1.09 Crore
Tender Fee 2600
EMD 2.18 Lakhs
Exemption Not Available
Document List
a2aa769b-e100-4332-8731-5cab36e28787.html
BOQ_1023375.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

a2aa769b-e100-4332-8731-5cab36e28787.html

xls

BOQ_1023375.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders