Housing Urban and Rular Development Government Departments Closing in 11 days TDR #56402478

Tender For Supply Installation Testing and Commissioning of Ac Machines And Allied Electrical Installation Work At G And O Operation Theatre Of Baghajatin S.G. Hospital, South 24 Parganas.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
2.27 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
11 days left
EMD
4551
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Ac Machines And Allied Electrical Installation Work At G And O Operation Theatre Of Baghajatin S.G. Hospital, South 24 Parganas.

BOQ

Name of Work:- SITC of AC machines and allied Electrical Installation work at G and O Operation Theatre of Baghajatin S.G. Hospital, South 24 Parganas.
Sl. No. Item Description
1SITC of Inverter type Concealed /Ductable split AC machines (a set of full metal body indoor and outdoor unit) having Cooling Capacity not less then 7.0KW for 2.0TR, with veriable speed rotary/scroll compressor, refrigerant gas R32/R410 or better, both condenser and Cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-l & Part-) with all amendments.(Make - Mitsubishi Electric/ Daikin/O-General/Hitachi /Voltas/Blue Star)
2Supply & Laying of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:- (Make: Royku/Rajco/Totaline/Mandeep)
3Discharge Line 9.5mm dia, min. thickness 0.8mm with 9mm thick nitrile insulation.
4Suction Line 19.05mm dia, min. thickness 0.99mm with 9mm thick nitrile insulation.
5Supply and laying of PVC drain pipe. (Make: Supreme/ finolex/Approved make)
6S & Laying of PVC hard pipes of 25mm sizes incl. insulation, fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. (Make: Supreme/ finolex/Approved make)
7Supply & Laying of 4 Core 1.5 sq.mm.unarmoured Cu control cable. 1.1 KV Gr. PVC/XLPE insulated Control cable incl.laying on wall surface by suitable clamping arrangement, proper glanding & finishing the cable ends with solderless sockets for following cables. (Make: RR Kabel /Gloster/ Polycab/Havells)
8Supply & Fixing 240 V,25 A, 3 pin Modular type plug top (Make- North-West/Crabtree/Legrand) with indicator & necy.Connections.
9Fabrication of suitable M.S. (Make: TATA/ Jindal/Sale) Structure by 2 nos of [(35x35x6mm)x4ft.] MS angle iron, angular supported by 02 nos [(35x35x6mm)x3ft.] and 01 no 35x6mmx4ft M.S flat for horizontal support with respect floor and both side welded for installation of 1 nos outdoor unit & fixed it in outside of concrete wall by cutting hole and grouted 03 nos MS angle & necessary scaffolding arrangement as per direction of EIC & painting the fabrication work with one coat of RO primer & 2 coat of oil paint(Make: Berger/Asianpaints/Approved make).
10Dismantling of existing window type air conditioning machine carefully and submit the same at sectional store. After dismantling the existing window AC, the cutting portion of the window to be covered by suitable size aluminium channel with ACP board (Approved make) with necessary arrangement to prevent air, water leakage as per direction of EIC.
11Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for Copper Pipe laying, per storey of building per vertical run.
12Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
13Supply & Fixing 240 V, 25 A, Modular type starter (Make: North-west/ Crabtree/Legrand) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
14Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Make: RR Kabel/ Polycab/Havells/ Mescab) in suitable size PVC rigid conduit 'FR' (Make: Precision/Polycab MMS/MHS type) incl. necy. fittings as required.
152 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC.
16Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(Make: Dowells)
172.5 sqmm
184.0 sqmm
19S & F Timer Control Unit for Air conditioner machine with following accessories:- i) 12-way SPNDB Box (Legrand/L & K)-1 no. ii) 25A DP MCB (Legrand/L & K)-1 no.iii)Digital 24 hour time switch (Make-GIC) -1no. iv)25A 2-pole contactor (L&K: MNX22/230V)-1no. v)Melamine terminal block-2 nos. vi)LED indicating lamp (L&K: SIL R 240V)-2 no. vii)2X4sq.mm+2.5sq.mm copper wire -2 mtr. viii)1.5sqmm copper wire-3 mtrs. ix) 3 way ON-OFF-ON toggle switch -- 1 no. x) cu socket of 4/2.5/1.5 sq mm -- L.Sxi) Single Phase AC starter (cat no-C 12M01 H)xii) Ammeter- 01(Make-L&K/ABB/Crabtree) with complete interconnection as required as per direction of EIC.
20Terms and condition
21The Agency must procure the materials from the Manufacturere/ OEM or from their authorised sales channel so that the standard warranty/ support of the Manufacturer/ OEM becomes applicable to the products to be delivered and installed by them.
22If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
23Defect liability period 1(one) year. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56402478
AUTHORITY Government Departments
TENDER VALUE 2.27 Lakhs
LAST DATE 22-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of Ac Machines And Allied Electrical Installation Work At G And O Operation Theatre Of Baghajatin S.G. Hospital, South 24 Parganas.
Basic Detail
Tender No WBPWD/AE/SKHESD-I/NIQ-06/26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 10 Jul 2026
Submission Date 22 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 2.27 Lakhs
Tender Fee Ref. Documents
EMD 4551
Exemption Not Available
Document List
Tendernotice_2 (2).pdf
433ecbf9-a3b2-4a66-b867-1f3a9615b89c.html
BOQ_5086304.xls
Tendernotice_1 (15).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_2 (2).pdf

html

433ecbf9-a3b2-4a66-b867-1f3a9615b89c.html

xls

BOQ_5086304.xls

pdf

Tendernotice_1 (15).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders