Housing Urban and Rular Development Government Departments Closing in 19 days TDR #56402448

Tender For Additional Estimate For Construction Of Deoc Building, Kamrup, Amingaon With Base Isolation Technology (Providing Floor Tiles, Wall Tiles, Granite Chowkath, Door Palla, Roof Grading, Ss Railing, Grill, Blinds Fire Extinguisher, Electrical

Issued by Government Departments · Kamrup, Assam
Tender Value
27.94 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
19 days left
EMD
55898
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Additional Estimate For Construction Of Deoc Building, Kamrup, Amingaon With Base Isolation Technology (Providing Floor Tiles, Wall Tiles, Granite Chowkath, Door Palla, Roof Grading, Ss Railing, Grill, Blinds Fire Extinguisher, Electrical Works Etc.)

BOQ

Name of Work:- Additional estimate for Construction of DEOC Building, Kamrup, Amingaon with Base Isolation Technology (Providing Floor tiles, wall tiles, granite Chowkath, door palla, Roof grading, SS Railing, grill, Blinds fire extinguisher, Electrical works etc.)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
2Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
4Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
5Cement plaster (in coarse sand) 12 mm cement plaster of mix1:4(1 cement:4 coarse sand)
612 mm cement plaster finished with a floating coat of neat cement of mix : 12 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
7Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
8Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
9Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm
10Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
12Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
13Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). SS Railing.
14Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.Fixed to steel windows by welding
15Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
16Supplying fitting & fixing Vertical Blinds as specified and directed by the department at all levels
17Supplying fitting & installation of New ABC stored pressure fire extinguishers 9 kg capacity including all accessories.
18Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter
19Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings :
20Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
21Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
22Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.23.2.2 . 150 mm nominal size dia
23Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
24Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
25Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
26Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work 40 mm nominal outer dia pipes
27Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia pipes
28Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
29Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A
30Group B
31Group C
32Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
33Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq mm + 1x2.5 sq. mm earth wire
342 X 4 sq. mm + 1 X 4 sq. mm earth wire
354 X 4 sq. mm + 2 X 4 sq. mm earth wire
364 X 6 sq. mm + 2 X 6 sq. mm earth wire
374 X 10 sq. mm + 2 X 6 sq. mm earth wire
38Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module (100mmX75mm)
394 Module (125mmX75mm)
406 Module (200mmX75mm)
418 Module (125mmX125mm)
4212 Module (200mmX150mm)
43Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A Switch
4415/16 A Switch
453 pin 5/6 A socket outlet
466 pin 15/16 A socket outlet
47Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
48Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
49Supplying and fixing brass batten/ angle holder including connection etc. as required.
50Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 24), Double door
51Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
52Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc as required. 125 A, 36KA, FPMCCB
53Supplying and fixing 5A to 32A rating, 240/415V, 10KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
54Earthing with GI Pipes 4.5 m long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
55Earthing with copper earth plate 600x600x3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal/ coke and salt as required.
56providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
57providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/ cable as required.
58Supplying with fitting and fixing of 40A 4P 10 KA 240/415 V 50 Hz MCB with making necessary connection as approved and directed by the deptt. (Legrand or equivalent make)
59Supplying with fitting and fixing of 63A 4P 10 KA 240/415 V 50 Hz MCB with making necessary connection as approved and directed by the deptt. (Legrand or equivalent make)
60Supplying including fitting fixing of following 1200 mm sweep 3 star A.C Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department[ without regulator], 9orient or equivalent make).
61Supplying including fitting fixing of following A.C exhaust in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department[ Trans Air 300 mm sweep (Crompton)
62Supplying, fitting & fixing of 12 W LED Bulb as required and as directed by the department.( Philips or equivalent make)
63Supplying, fitting & fixing of 18 W LED Tube Light (Retrofit type) fitting (4ft) as required and as directed by the department.( Philips or equivalent make)
64Supplying including installation, connection as approved by the Deptt., testing and commissioning of 3 HP Capacity SUBMERSIBLE PUMP SE 3 ( Three phase) with steel cable rope and sumersible cable complete as directed as directed and specified by the Deptt. Three phase submersible motor pump set( Texmo/ Crompton greaves/ Aquatic/ CRI/ V-GUAR suitable for 100 mm bore well and above.
65Supplying with installation testig and commissioning of 3 HP Starter control panel make crompton complete including making necessary connection etc. as required complete and as directed by the Department.
66Supplying with installation testig and commissioning of 3 core 6 sq mm Submersible cable make Gloster make complete including making necessary connection etc. as required complete and as directed by the Department.
67Supply and laying of Hot Dip Rope for Wire Rope Barrier for Submersible pum set as approved by this Deptt. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56402448
AUTHORITY Government Departments
TENDER VALUE 27.94 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Additional Estimate For Construction Of Deoc Building, Kamrup, Amingaon With Base Isolation Technology (Providing Floor Tiles, Wall Tiles, Granite Chowkath, Door Palla, Roof Grading, Ss Railing, Grill, Blinds Fire Extinguisher, Electrical Works Etc.)
Basic Detail
Tender No CS/SE(B-1)/166/2026-27/219-30 Dtd.03/07/2026
Bidding Type Tender
Location
City Kamrup
State Assam
Key Dates
Publish Date 10 Jul 2026
Submission Date 30 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 27.94 Lakhs
Tender Fee 600
EMD 55898
Exemption Available
Document List
50b53d1a-16a7-468a-9273-4f3cac8722f7.html
BOQ_83593.xls
SBD.pdf
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

50b53d1a-16a7-468a-9273-4f3cac8722f7.html

xls

BOQ_83593.xls

pdf

SBD.pdf

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender