Power Government Departments Closing in 31 days TDR #56401436

Tender For Procurement Of Different Type Of Electrical Panel Equipment Of Auxiliaries For 3 X 105 Mw Thps-I Sirmour & 3X20 Mw, Bs-Iii, Hps Mppgcl, Deolond Of Thc Sirmour

Issued by Government Departments · Rewa, Madhya Pradesh
Tender Value
5.28 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
31 days left
EMD
10600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rewa → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Procurement Of Different Type Of Electrical Panel Equipment Of Auxiliaries For 3 X 105 Mw Thps-I Sirmour & 3X20 Mw, Bs-Iii, Hps Mppgcl, Deolond Of Thc Sirmour , Auxiliary Contractor, Rated Insulation Voltage = 690 Volt, Rated Operational Current Le (A) (230 V), (Le/Ac15) = 10Amp, Lth2=16 A, Conforming To Iec947, Auxiliary Contracts - 3No + 1 Nc Coil Voltage = 220 Volt Dc, Model -3Th80 31-0B (Siemens), Make -Siemens /L&T/Schneider Or Equivalent , Auxiliary Contactor, Rated Insulation Voltage = 690 Volt, Rated Operational Current (A) (230 V) (Le/Ac15) = 10Amp, Lth2=16 A, Conforming To Iec947 Auxiliary Contacts - 6No + 2 Nc, Coil Voltage = 220 Volt Dc, Model - 3Th82 62-0B (Siemens) Make -Siemens /L&T/Schneider Or Equivalent , Contactor Relay (Industrial Grade) For Electro Hydraulic Governor Panel, Coil Voltage = 220 Vdc, Auxiliary Contacts - 4No + 4 Nc, Rated Operational Current (A) (230 V Dc / 380 V Ac) (Le) = 6 A And For 500 V Ac - Ie = 4 A, Vde - 660 Volt, Ith2 = 16 Amp, Coil R(Warm) = 7500 Ohm, Model - 3Ta-6160-0Bm (Siemens), Make -Siemens /L&T/ Schneider Or Equivalent , Ac Power Contactor, 3 Pole, Rated Operational Current Ie At 55 Dec C (Utilization Category Ac-3) = 12 A For 5.5 Kw, 415 V Ac, Coil Voltage = 230 V Ac, No. Of Built-In Auxiliary Contacts = 1 Nc (Ie Ac-15 = 4 A, 415 Volt Ac And Ithe = 10 A), Model - Mn 12, Make = L&T Separate Auxiliary Contact Block - Contacts = 1 No + 1 Nc, Ie Ac-15 = 4 A, 415 Volt Ac And Ithe = 10 A, Model = Mn-A1, Make -Siemens /L&T/ Schneider Or Equivalent , Thermal Overload Relay, Mounting - Direct, Suitable For Contactor - Mn 12, 1 Start & Off / Reset Push Button, Built In Contacts = 2 No + 1 Nc, Rated Operational Current For Ac-15 Utilization Category At 50 Hz = 2 A At 500 V, Max Fuse = 6 A, Current Range = 0.9 - 1.2 - 1.5 Amp. Model Mn 2 (Suitable For Item S.No.4), Make -Siemens /L&T/Schneider Or Equivalent , Control Contractor, Main Contact = 4 No, Ie (Rated Current) For Ac-11, Utilization Category = 4 A At 415 V, 50 Hz, Rating For Motor Duty (Ac-3) = 7.5 A, 415 V, 50 Hz, Thermal Rating = 10 A, Coil Consumption = Pick Up 85 Va Hold On 16 Va (5 Watts), Coil Rated Supply = 230 V Ac, Model - Mm00 - L&T (For Reference),Make - C&S/ Siemens / L&T / Schneider Or Equivalent , Vsp D2 Phase Failure Relay, System Supply 415 V Ac, Auxiliary Supply 415 V Ac, Output Contacts 2 Co, Trip Setting (Volts) - Phase Sequence Yes, Phase Imbalance 30 V To 70 V ±6 V Adjustable, Resetting Mode Manual, Trip Time Delay 3.5 Sec / 1.5 Sec, Make - Minilec Or Equivalent , Power Contactor, 3 Pole, 415 V Ac, Rated Operational Current Ie = 32 Amp, Auxiliary Contacts = 2No + 2Nc, Coil Voltage = 240 V Ac, Make - C&S/ Siemens /L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 28-40 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor S. No. 8) Make - C&S/ Siemens / L&T/Schneider Or Equivalent , Auxiliary Contactor, Main Contacts = 2No+2Nc, Rated Operational Current Ie (Ac11 415 V Ac) = 4 A, Ith = 10 A, Ui = 660 V, Coil Voltage = 240 V Ac, Auxiliary Contact Block = 2 No + 2 Nc, Make -C&S / Siemens / L&T/ Schneider Or Equivalent , Power Contactor, 3 Pole, 415 V Ac, No. Of Built-In Auxiliary Contacts = 1 No, Rated Operational Current Ie = 63 Amp, Auxiliary Contacts = 2No + 2 Nc, Coil Voltage = 240 V Ac, Make -C&S / Siemens / L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 57-66 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor For S. No. 11), Make -C&S / Siemens / L&T/ Schneider Or Equivalent , Power Contactor, 3 Pole, 415 V Ac, No. Of Built-In Auxiliary Contacts = 1 No, Rated Operational Current Ie = 40 Amp, Auxiliary Contacts = 2No + 2 Nc, Coil Voltage = 240 V Ac, Make -C&S / Siemens / L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 30-40 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor For S.No. 13), Make -C&S / Siemens / L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 23-32 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor S. No. 13), Make -C&S / Siemens / L&T/ Schneider Or Equivalent , Led Semaphore Indicator, 220 Vdc, Moulded Case, Spl. Semaphore, Type - Vam12xf8005ad (For Reference), Diameter (Maximum) = 68 Mm, Panel Cut-Out = 51 Mm, With Suitable Adapter Plate Of Black Colour Of Size 83 Mm X 83 Mm And 1 Mm Thickness As Per Existing Mimic Diagram Of Control And Relay Panel , Led Semaphore Indicator, 220 Vdc, Moulded Case, Spl. Semaphore, Type - Vam12xf8005ad (For Reference), Diameter (Maximum) = 68 Mm, Panel Cut-Out = 51 Mm, With Suitable Adapter Plate Of Gray Colour Of Size 68 Mm X 68 Mm And 1 Mm Thickness As Per Existing Mimic Diagram Of Control And Relay Panel , Power Rectifier Diode (Blocking Diode) By127 B6, Make - Bel Or Equivalent. Technical Specification: (A) Maximum Average Forward Rectified Current 1 (B)Maximum Repetitive Peak Reverse Voltage 1250 V; (C) Maximum Rms Voltage 875 V; (D) Maximum Dc Blocking Voltage 1250 V; (E) Maximum Forward Voltage At 1A Dc 1.1 V; (F) Low Forward Voltage Drop (G) High Current Capability(H) High Surge Capability, Make - Bel Or Equivalent , Led Indication Lamp Single Steady Colour & Round In Shape Suitable For Voltage 220 Vdc And 11 Mm Dia. Panel Cut Out, Colour - White, Make - L&T / Vaishno Or Equivalent

BOQ

Name of Work:- Procurement of different type of electrical panel equipment of auxiliaries for 3 x 105 MW THPS-I Sirmour & 3x20 MW, BS-III, HPS MPPGCL, Deolond of THC Sirmour
Sl. No. Item Description
1Auxiliary Contractor, Rated Insulation Voltage = 690 Volt, Rated operational current le (A) (230 V), (le/AC15) = 10Amp, lth2=16 A, conforming to IEC947, Auxiliary Contracts – 3NO + 1 NC Coil Voltage = 220 Volt DC, Model -3TH80 31-0B (Siemens), Make –Siemens /L&T/Schneider or equivalent
2Auxiliary Contactor, Rated Insulation Voltage = 690 Volt, Rated operational current (A) (230 V) (le/AC15) = 10Amp, lth2=16 A, conforming to IEC947 Auxiliary Contacts – 6NO + 2 NC, Coil Voltage = 220 Volt DC, Model – 3TH82 62-0B (Siemens) Make –Siemens /L&T/Schneider or equivalent
3Contactor Relay (Industrial Grade) for Electro Hydraulic Governor Panel, Coil Voltage = 220 VDC, Auxiliary Contacts – 4NO + 4 NC, Rated operational current (A) (230 V DC / 380 V AC) (le) = 6 A and for 500 V AC - Ie = 4 A, VDE - 660 Volt, Ith2 = 16 Amp, Coil R(warm) = 7500 Ohm, Model – 3TA-6160-0BM (Siemens), Make –Siemens /L&T/ Schneider or equivalent
4AC Power Contactor, 3 Pole, Rated operational current Ie at 55 Dec C (Utilization category AC-3) = 12 A for 5.5 kW, 415 V AC, Coil Voltage = 230 V AC, No. of built-in auxiliary contacts = 1 NC (Ie AC-15 = 4 A, 415 Volt AC and Ithe = 10 A), Model – MN 12, Make = L&TSeparate Auxiliary Contact block – Contacts = 1 NO + 1 NC, Ie AC-15 = 4 A, 415 Volt AC and Ithe = 10 A, Model = MN-A1, Make –Siemens /L&T/ Schneider or equivalent
5Thermal Overload Relay, Mounting – Direct, Suitable for Contactor – MN 12, 1 Start & Off / Reset Push button, Built in contacts = 2 NO + 1 NC, Rated operational current for AC-15 utilization category at 50 Hz = 2 A at 500 V, Max Fuse = 6 A, Current Range = 0.9 – 1.2 – 1.5 Amp. Model MN 2 (Suitable for item S.no.4), Make –Siemens /L&T/Schneider or equivalent
6Control Contractor, Main Contact = 4 NO, Ie (Rated Current) for AC-11, Utilization Category = 4 A at 415 V, 50 Hz, Rating for motor duty (AC-3) = 7.5 A, 415 V, 50 Hz, Thermal Rating = 10 A, Coil Consumption = Pick up 85 VA Hold on 16 VA (5 watts), Coil Rated supply = 230 V AC, Model – MM00 – L&T (for reference),Make – C&S/ Siemens / L&T / Schneider or equivalent
7VSP D2 Phase Failure Relay, System Supply 415 V AC, Auxiliary Supply 415 V AC, Output Contacts 2 CO, Trip Setting (Volts) – Phase Sequence Yes, Phase Imbalance 30 V to 70 V ±6 V adjustable, Resetting Mode Manual, Trip Time Delay 3.5 sec / 1.5 sec, Make – Minilec or equivalent
8Power Contactor, 3 Pole, 415 V AC, Rated operational current Ie = 32 Amp, Auxiliary Contacts = 2NO + 2NC, Coil Voltage = 240 V AC, Make – C&S/ Siemens /L&T/Schneider or equivalent
9Thermal Overload Relay, with single phasing preventing feature inbuilt. Setting Range 28-40 A, Auxiliary Contacts – 1NO+1NC (Suitable for above contactor S. No. 8) Make – C&S/ Siemens / L&T/Schneider or equivalent
10Auxiliary Contactor, Main Contacts = 2NO+2NC, Rated operational Current Ie (AC11 415 V AC) = 4 A, Ith = 10 A, Ui = 660 V, Coil Voltage = 240 V AC, Auxiliary Contact Block = 2 NO + 2 NC, Make –C&S / Siemens / L&T/ Schneider or equivalent
11Power Contactor, 3 Pole, 415 V AC, No. of built-in auxiliary contacts = 1 NO, Rated operational current Ie = 63 Amp, Auxiliary Contacts = 2NO + 2 NC, Coil Voltage = 240 V AC, Make –C&S / Siemens / L&T/Schneider or equivalent
12Thermal Overload Relay, with single phasing preventing feature inbuilt. Setting Range 57-66 A, Auxiliary Contacts – 1NO+1NC (Suitable for above contactor for S. No. 11),Make –C&S / Siemens / L&T/ Schneider or equivalent
13Power Contactor, 3 Pole, 415 V AC, No. of built-in auxiliary contacts = 1 NO, Rated operational current Ie = 40 Amp, Auxiliary Contacts = 2NO + 2 NC, Coil Voltage = 240 V AC, Make –C&S / Siemens / L&T/Schneider or equivalent
14Thermal Overload Relay, with single phasing preventing feature inbuilt. Setting Range 30-40 A, Auxiliary Contacts – 1NO+1NC (Suitable for above contactor for S.No. 13),Make –C&S / Siemens / L&T/Schneider or equivalent
15Thermal Overload Relay, with single phasing preventing feature inbuilt. Setting Range 23-32 A, Auxiliary Contacts – 1NO+1NC (Suitable for above contactor S. No. 13),Make –C&S / Siemens / L&T/ Schneider or equivalent
16LED Semaphore Indicator, 220 VDC, Moulded case, SPL. Semaphore, Type – VAM12XF8005AD (For Reference), Diameter (Maximum) = 68 mm, Panel Cut-Out = 51 mm, with suitable adapter plate of black colour of size 83 mm x 83 mm and 1 mm thickness as per existing mimic diagram of control and relay panel
17LED Semaphore Indicator, 220 VDC, Moulded case, SPL. Semaphore, Type – VAM12XF8005AD (For Reference), Diameter (Maximum) = 68 mm, Panel Cut-Out = 51 mm, with suitable adapter plate of Gray colour of size 68 mm x 68 mm and 1 mm thickness as per existing mimic diagram of control and relay panel
18Power Rectifier Diode (Blocking Diode) BY127 B6, Make – BEL or equivalent.Technical Specification: (a) Maximum Average Forward Rectified Current 1 Amp; (b)Maximum Repetitive Peak Reverse Voltage 1250 V; (c) Maximum RMS Voltage 875 V; (d) Maximum DC Blocking Voltage 1250 V; (e) Maximum Forward Voltage at 1A DC 1.1 V; (f) Low forward voltage drop (g) High current capability(h) High surge capability, Make - BEL or equivalent
19LED indication Lamp single steady colour & round in shape suitable for voltage 220 VDC and 11 mm dia. panel cut out, colour – White, Make – L&T / Vaishno or equivalent Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56401436
AUTHORITY Government Departments
TENDER VALUE 5.28 Lakhs
LAST DATE 11-08-2026
Authority
Authority Name Madhya Pradesh Power Generating Company Limited
Work Description Tender for Procurement Of Different Type Of Electrical Panel Equipment Of Auxiliaries For 3 X 105 Mw Thps-I Sirmour & 3X20 Mw, Bs-Iii, Hps Mppgcl, Deolond Of Thc Sirmour , Auxiliary Contractor, Rated Insulation Voltage = 690 Volt, Rated Operational Current Le (A) (230 V), (Le/Ac15) = 10Amp, Lth2=16 A, Conforming To Iec947, Auxiliary Contracts - 3No + 1 Nc Coil Voltage = 220 Volt Dc, Model -3Th80 31-0B (Siemens), Make -Siemens /L&T/Schneider Or Equivalent , Auxiliary Contactor, Rated Insulation Voltage = 690 Volt, Rated Operational Current (A) (230 V) (Le/Ac15) = 10Amp, Lth2=16 A, Conforming To Iec947 Auxiliary Contacts - 6No + 2 Nc, Coil Voltage = 220 Volt Dc, Model - 3Th82 62-0B (Siemens) Make -Siemens /L&T/Schneider Or Equivalent , Contactor Relay (Industrial Grade) For Electro Hydraulic Governor Panel, Coil Voltage = 220 Vdc, Auxiliary Contacts - 4No + 4 Nc, Rated Operational Current (A) (230 V Dc / 380 V Ac) (Le) = 6 A And For 500 V Ac - Ie = 4 A, Vde - 660 Volt, Ith2 = 16 Amp, Coil R(Warm) = 7500 Ohm, Model - 3Ta-6160-0Bm (Siemens), Make -Siemens /L&T/ Schneider Or Equivalent , Ac Power Contactor, 3 Pole, Rated Operational Current Ie At 55 Dec C (Utilization Category Ac-3) = 12 A For 5.5 Kw, 415 V Ac, Coil Voltage = 230 V Ac, No. Of Built-In Auxiliary Contacts = 1 Nc (Ie Ac-15 = 4 A, 415 Volt Ac And Ithe = 10 A), Model - Mn 12, Make = L&T Separate Auxiliary Contact Block - Contacts = 1 No + 1 Nc, Ie Ac-15 = 4 A, 415 Volt Ac And Ithe = 10 A, Model = Mn-A1, Make -Siemens /L&T/ Schneider Or Equivalent , Thermal Overload Relay, Mounting - Direct, Suitable For Contactor - Mn 12, 1 Start & Off / Reset Push Button, Built In Contacts = 2 No + 1 Nc, Rated Operational Current For Ac-15 Utilization Category At 50 Hz = 2 A At 500 V, Max Fuse = 6 A, Current Range = 0.9 - 1.2 - 1.5 Amp. Model Mn 2 (Suitable For Item S.No.4), Make -Siemens /L&T/Schneider Or Equivalent , Control Contractor, Main Contact = 4 No, Ie (Rated Current) For Ac-11, Utilization Category = 4 A At 415 V, 50 Hz, Rating For Motor Duty (Ac-3) = 7.5 A, 415 V, 50 Hz, Thermal Rating = 10 A, Coil Consumption = Pick Up 85 Va Hold On 16 Va (5 Watts), Coil Rated Supply = 230 V Ac, Model - Mm00 - L&T (For Reference),Make - C&S/ Siemens / L&T / Schneider Or Equivalent , Vsp D2 Phase Failure Relay, System Supply 415 V Ac, Auxiliary Supply 415 V Ac, Output Contacts 2 Co, Trip Setting (Volts) - Phase Sequence Yes, Phase Imbalance 30 V To 70 V ±6 V Adjustable, Resetting Mode Manual, Trip Time Delay 3.5 Sec / 1.5 Sec, Make - Minilec Or Equivalent , Power Contactor, 3 Pole, 415 V Ac, Rated Operational Current Ie = 32 Amp, Auxiliary Contacts = 2No + 2Nc, Coil Voltage = 240 V Ac, Make - C&S/ Siemens /L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 28-40 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor S. No. 8) Make - C&S/ Siemens / L&T/Schneider Or Equivalent , Auxiliary Contactor, Main Contacts = 2No+2Nc, Rated Operational Current Ie (Ac11 415 V Ac) = 4 A, Ith = 10 A, Ui = 660 V, Coil Voltage = 240 V Ac, Auxiliary Contact Block = 2 No + 2 Nc, Make -C&S / Siemens / L&T/ Schneider Or Equivalent , Power Contactor, 3 Pole, 415 V Ac, No. Of Built-In Auxiliary Contacts = 1 No, Rated Operational Current Ie = 63 Amp, Auxiliary Contacts = 2No + 2 Nc, Coil Voltage = 240 V Ac, Make -C&S / Siemens / L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 57-66 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor For S. No. 11), Make -C&S / Siemens / L&T/ Schneider Or Equivalent , Power Contactor, 3 Pole, 415 V Ac, No. Of Built-In Auxiliary Contacts = 1 No, Rated Operational Current Ie = 40 Amp, Auxiliary Contacts = 2No + 2 Nc, Coil Voltage = 240 V Ac, Make -C&S / Siemens / L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 30-40 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor For S.No. 13), Make -C&S / Siemens / L&T/Schneider Or Equivalent , Thermal Overload Relay, With Single Phasing Preventing Feature Inbuilt. Setting Range 23-32 A, Auxiliary Contacts - 1No+1Nc (Suitable For Above Contactor S. No. 13), Make -C&S / Siemens / L&T/ Schneider Or Equivalent , Led Semaphore Indicator, 220 Vdc, Moulded Case, Spl. Semaphore, Type - Vam12xf8005ad (For Reference), Diameter (Maximum) = 68 Mm, Panel Cut-Out = 51 Mm, With Suitable Adapter Plate Of Black Colour Of Size 83 Mm X 83 Mm And 1 Mm Thickness As Per Existing Mimic Diagram Of Control And Relay Panel , Led Semaphore Indicator, 220 Vdc, Moulded Case, Spl. Semaphore, Type - Vam12xf8005ad (For Reference), Diameter (Maximum) = 68 Mm, Panel Cut-Out = 51 Mm, With Suitable Adapter Plate Of Gray Colour Of Size 68 Mm X 68 Mm And 1 Mm Thickness As Per Existing Mimic Diagram Of Control And Relay Panel , Power Rectifier Diode (Blocking Diode) By127 B6, Make - Bel Or Equivalent. Technical Specification: (A) Maximum Average Forward Rectified Current 1 (B)Maximum Repetitive Peak Reverse Voltage 1250 V; (C) Maximum Rms Voltage 875 V; (D) Maximum Dc Blocking Voltage 1250 V; (E) Maximum Forward Voltage At 1A Dc 1.1 V; (F) Low Forward Voltage Drop (G) High Current Capability(H) High Surge Capability, Make - Bel Or Equivalent , Led Indication Lamp Single Steady Colour & Round In Shape Suitable For Voltage 220 Vdc And 11 Mm Dia. Panel Cut Out, Colour - White, Make - L&T / Vaishno Or Equivalent
Basic Detail
Tender No 485481
Bidding Type Tender
Location
City Rewa
State Madhya Pradesh
Key Dates
Publish Date 10 Jul 2026
Submission Date 11 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 5.28 Lakhs
Tender Fee 500
EMD 10600
Exemption Available
Document List
1_SBD_SUPPLY_AMEND.pdf
22c5a123-0c1f-4e05-b315-5cf94e210ac3.html
2TnCSchedulePurchase.xls
BOQ_626985.xls
nitpdf.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 31 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 33 days

Tender Documents

Download All (ZIP) ↓
pdf

1_SBD_SUPPLY_AMEND.pdf

html

22c5a123-0c1f-4e05-b315-5cf94e210ac3.html

xls

2TnCSchedulePurchase.xls

xls

BOQ_626985.xls

pdf

nitpdf.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders