Tender For Certain E/M Sanctioned Works Under Ge (I) (Cg) Ratnagiri.
Tender Overview
Project Description
Tender For Certain E/M Sanctioned Works Under Ge (I) (Cg) Ratnagiri.- 1 Supply And Fix Air Cooled Split Unit Air Conditioner Electric Driven, Single Phase, Complete With Cordless Remote-Control Unit And Within Built Air Ioniser And Plasma Filter For Better Indoor Air Quality Of Capacity Of 1.5 Ton Of Refrigeration, Bee 5 Star Rated Invertor Type And Making The Surface Good To Match The Existing Complete All As Specified And Directed By Engineer In Charge. 2 Supply And Fix Air Cooled Split Unit Air Conditioner Electric Driven, Single Phase, Complete With Cordless Remote-Control Unit And Within Built Air Ioniser And Plasma Filter For Better Indoor Air Quality Of Capacity Of 2.0 Ton Of Refrigeration, Bee 5 Star Rated Invertor Type And Making The Surface Good To Match The Existing Complete All As Specified And Directed By Engineer In Charge. 3 Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air-Cooled Indoor Type & Designed For Input Variation Between 130 To 280 Volts With Output Voltage Stabilized At 230 Volts With Accuracy Of ± 2.5% And Of Capacity 5 Kva Suitable Up To 2-Ton Ac Complete All As Specified And Directed By Engineer In Charge. 4 Supply, Laying And Testing Cable Xlpe Insulated Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 50 Sqmm 3.5 Core Complete All As Specified And Directed. 5 Excavating In Trenches, Not Exceeding 1.5 Metres Wide And Not Exceeding 1.5 Metres In Depth; For Foundation, Laying Of Cables, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10 Sqm On Plan And Not Exceeding 1.5 Metres In Depth And Getting Out Hard/Dense Soil Complete All As Specified And Directed By Engineer-In-Charge. 6 Returning, Filling In, Including Spreading, Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Hard/Dense Soil Complete All As Specified And Directed. 7 Removing Of Excavated Soil Not Exceeding 50 Metres And Depositing Where Directed At A Level Not Exceeding 1.5 Metres Above The Starting Points All As Directed By Engineer-In-Charge. 8 Supply And Fix Of Mccb Incoming Tpn Db Vertical Type, Suitable For 63 Amps Mccb As Incomer, Made Of Sheet Steel, Powder Painted With Neutral Busbar 100 Amps Rating, Neutral Link, Ip-43-Ik09 Protection Grade, 415 Volts Vtpn With 4-Way Double Door Complete All As Specified And Directed. 9 Supply And Fixing 240 Volts, 10 Ka C Curve Miniature Circuit Breaker (Mcb) Of Single Poles And Current Carrying Capacity 20 Amps, In The Mcb Db Complete With Connection Testing And Commissioning Complete All As Specified And Directed. 10 Supply And Fixing Mccb 4 Pole, 415 Volts, Thermal Adjustable Type, 63 Amps With Breaking Capacity 25 Ka Complete All As Specified And Directed By Engineer-In-Charge. 11 Material And Labour For Wiring For Circuit/Submain Wiring Along With Earth Wire With The 2 Runs Of 16.0 Sqmm One Run Of 16.0 Sqmm Earth Wire Size Of Fr, Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed As Required In Pvc Casing Caping Complete All As Specified And Directed.Note: Three Runs Of 16 Sqmm And Pvc Casing Shall Be Considered As One Rm. 12 Material And Labour For Wiring For Circuit/Submain Wiring Along With Earth Wire With The 2 Runs Of 6.0 Sqmm One Run Of 6.0 Sqmm Earth Wire Size Of Fr, Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed As Required In Pvc Casing Caping Complete All As Specified And Directed.Note: Three Runs Of 6 Sqmm And Pvc Casing Shall Be Considered As One Rm. 13 Supply And Fixing Of Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb Of 20 Amps Complete All As Specified And Directed. 14 Material And Labour For Relocation/Shifting Of Lights Fittings And Allied Wiring To Specified Location And Making The Surface Good To Match As Existing Complete All As Specified And Directed. 15 Material And Labour For Road Cutting And Repairing The Same With Road Patch Material Width Up To 75 Cm For Laying 40Mm Dia Pipe Complete All As Specified And Directed. 16 Material And Labour For Gl Tubing Medium Grade Of 40Mm Dia With All Fitting/Accessories For Protection Of Cable On Pole/Wall And Under Road Crossing Including Clamps, Nuts Bolts Etc Complete All As Specified And Directed. 17 Supply, Fixing And Testing Of 3 Ac Digital Timer (Iso Certified) Switch Heavy Duty Advanced Changeover For 3 AcS Operation With Rated Voltage 230 Volts Ac And Lcd Display Wall Mounted Type Programmable From 1 To 8 Hours For Each Ag And Connector Capacity 250 Amps Heavy Duty Backlite Connector Complete All As Specified And Directed At Site By Engineer-In-Charge. 18 Supply And Fix Rigid Non-Metallic Pvc Conduit As Drain Pipe Of Size 20 Mm Dia For Ac Water Outlet Inclusive Of All Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc Fixed Along Wall And Leaving The Outlet In The Drain Nearby Complete All As Specified And Directed. 19 Supply And Fix Pvc Frls Cable Duct Of Size 100Mm X 50Mm Fixed On Wall With Un Slotted Type Non Slip Cover Including With All Accessories Including Fixing Plug, Cable Tie Attachment, Wire Retainer Mounting Clamp Angle/Corner Duct, Channel Etc Complete All As Specified And Directed. 20 Supply, Laying And Testing Cable Xlpe Insulated Screened, Pvc Bedded Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sqmm 4 Core Complete All As Specified And Directed. 21 Supply & Laying Of 3 Core 1.5 Sqmm Pvc Sheath Pvc Insulated Flexible Copper Conductor Cable Complete All As Specified And Directed. 22 Supply And Fix Rigid Non-Metallic Pvc Conduit As Drain Pipe Of Size 25 Mm Dia For Ac Water Outlet Inclusive Of All Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc Fixed Along Wall And Leaving The Outlet In The Drain Nearby Complete All As Specified And Directed. 23 Supply And Laying High Density Polyethylene Pipes (Hdpe) Of Bore 25 Mm Laid In Trenches For Protection Of Electric Cable Complete All As Specified And Directed. 24 Supply And Installation Of Fast Earth Electrode 3.0 Metre Length Size Model F84, Having Two Mild Steel Pipe One Inside The Other With Proper Not Deep Galvanised Outer Dia 88 Mm And Inner Dia 48 Mm And The Cavity Between The Rod Pipes Is Filled With Ground Resistance Improment Powder, Sealed With Both End The Outer Pipe Of Electrode Should Be Zinc Coated, The Electrode Should Buried Directly In The Ground By Making Boring Of Diameter 10\ With Boring Machine Highly Conductive Non-Magnetic And Non-Corrosives Is To Be Connected With 6Mm Gl Wire Of Required Length To Facilitate Further Connection To Earth Dolly And Provision Of Earthing Chamber In Bricks Wall Of Size 45X45X15 Cm And Having Pcc Cover Of Required Size Complete All As Specified And As Directed. 25 Supply And Fix Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc, As Required 6Mm Dia Galvanised Iron Or Steel Wire Complete All As Specified And Directed. 26 Supply And Fix Light Junction Boxes Of Dimension (130X130X77 Mm), Shockproof, Rustproof, Termite Resistant, Weather Proof, Of Ip 66 And Cable Entry From Bottom Pole/ Bollard Light Mounting Arrangement Including Along With Connectors, Terminals And Insulators And Mcb Sp 10 Amps Rating With Provision Of Mcb, Cable Glands, Flexible Pvc Conduit Complete All As Specified And Directed. 27 Supply And Fix Led Bollard Light Suitable For Landscape Lighting, Ip 65 Protection, Inverted Pyramid Tripod Type, Soft 360° Light Distribution, Maximum Power Consumption Shall Be 10Watts, 3 Stage Cccv Driver With Minimum 4Kv Surge Protection Voltage Range Of 150-270 Volt Ac, Cct Around 3000K Or Warm White Light And Connecting Accessories Complete All As Specified And Directed At Site By Engineer-In-Charge.Note:- Rate Quoted Included For Excavation & Earth Work.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Fix air cooled split unit air conditioner electric driven, single phase, complete with cordless remote-control unit and within built air ioniser and Plasma filter for better indoor air quality of capacity of 1.5 Ton of Refrigeration, BEE 5 star rated invertor type and making the surface good to match the existing complete all as specified and directed by Engineer in Charge. |
| 2 | Supply and Fix air cooled split unit air conditioner electric driven, single phase, complete with cordless remote-control unit and within built air ioniser and Plasma filter for better indoor air quality of capacity of 2.0 Ton of Refrigeration, BEE 5 star rated invertor type and making the surface good to match the existing complete all as specified and directed by Engineer in Charge. |
| 3 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air-cooled indoor type & designed for input variation between 130 to 280 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA suitable up to 2-ton AC complete all as specified and directed by Engineer in Charge. |
| 4 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed. |
| 5 | Excavating in trenches, not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth; for foundation, laying of cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 metres in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-charge. |
| 6 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed. |
| 7 | Removing of excavated soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metres above the starting points all as directed by Engineer-in-Charge. |
| 8 | Supply and fix of MCCB incoming TPN DB vertical type, suitable for 63 Amps MCCB as incomer, made of sheet steel, powder painted with neutral busbar 100 amps rating, neutral link, IP-43-IK09 protection grade, 415 Volts VTPN with 4-way double door complete all as specified and directed. |
| 9 | Supply and fixing 240 Volts, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 20 amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 10 | Supply and fixing MCCB 4 Pole, 415 Volts, Thermal Adjustable type, 63 Amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material and labour for wiring for circuit/submain wiring along with earth wire with the 2 runs of 16.0 sqmm one run of 16.0 sqmm earth wire size of FR, PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC casing caping complete all as specified and directed.Note: Three runs of 16 Sqmm and PVC Casing shall be considered as one RM. |
| 12 | Material and labour for wiring for circuit/submain wiring along with earth wire with the 2 runs of 6.0 sqmm one run of 6.0 sqmm earth wire size of FR, PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC casing caping complete all as specified and directed.Note: Three runs of 6 Sqmm and PVC Casing shall be considered as one RM. |
| 13 | Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and directed. |
| 14 | Material and labour for relocation/shifting of lights fittings and allied wiring to specified location and making the surface good to match as existing complete all as specified and directed. |
| 15 | Material and Labour for road cutting and repairing the same with road patch material width up to 75 cm for laying 40mm dia pipe complete all as specified and directed. |
| 16 | Material and Labour for Gl tubing medium grade of 40mm dia with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nuts bolts etc complete all as specified and directed. |
| 17 | Supply, Fixing and testing of 3 AC digital timer (ISO Certified) switch heavy duty advanced changeover for 3 AC's operation with rated voltage 230 Volts AC and LCD display wall mounted type programmable from 1 to 8 hours for each AG and connector capacity 250 Amps heavy duty backlite connector complete all as specified and directed at site by Engineer-in-Charge. |
| 18 | Supply and fix rigid non-metallic PVC conduit as drain pipe of size 20 mm dia for AC water outlet inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc fixed along wall and leaving the outlet in the drain nearby complete all as specified and directed. |
| 19 | Supply and fix PVC FRLS cable duct of size 100mm X 50mm fixed on wall with un slotted type non slip cover including with all accessories including fixing plug, cable tie attachment, wire retainer mounting clamp angle/corner duct, channel etc complete all as specified and directed. |
| 20 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. |
| 21 | Supply & Laying of 3 Core 1.5 sqmm PVC sheath PVC insulated flexible copper conductor cable complete all as specified and directed. |
| 22 | Supply and fix rigid non-metallic PVC conduit as drain pipe of size 25 mm dia for AC water outlet inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc fixed along wall and leaving the outlet in the drain nearby complete all as specified and directed. |
| 23 | Supply and laying High density polyethylene pipes (HDPE) of bore 25 mm laid in trenches for protection of electric cable complete all as specified and directed. |
| 24 | Supply and installation of fast earth electrode 3.0 metre length size model F84, having two Mild Steel pipe one inside the other with proper not deep galvanised outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zinc coated, the electrode should buried directly in the ground by making boring of diameter 10\\" with boring machine highly conductive non-magnetic and non-corrosives is to be connected with 6mm Gl wire of required length to facilitate further connection to earth dolly and provision of earthing chamber in bricks wall of size 45x45x15 cm and having PCC cover of required size complete all as specified and as directed. |
| 25 | Supply and Fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required 6mm dia galvanised iron or steel wire complete all as specified and directed. |
| 26 | Supply and Fix light junction boxes of Dimension (130x130x77 mm), shockproof, rustproof, termite resistant, weather proof, of IP 66 and cable entry from bottom pole/ bollard light mounting arrangement including along with connectors, terminals and insulators and MCB SP 10 Amps rating with provision of MCB, Cable Glands, flexible PVC conduit complete all as specified and directed. |
| 27 | Supply and Fix LED Bollard light suitable for landscape lighting, IP 65 protection, inverted pyramid tripod type, soft 360° light distribution, Maximum power consumption shall be 10Watts, 3 stage CCCV driver with minimum 4KV surge protection voltage range of 150-270 Volt AC, CCT around 3000K or warm white light and connecting accessories complete all as specified and directed at site by Engineer-in-Charge.Note:- Rate quoted included for excavation & earth work. |
| 28 | Material and labour for Cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work, foundation bolts of lights, fair finishing to exposed surfaces using extra cement complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 29 | Material and labour for Cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work, foundation bolts of lights, fair finishing to exposed surfaces using extra cement complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender