Project Description
Tender For Demolition And Reconstruction Of Bcr At 24 Ed Af- 1 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out And Getting Out In Soft/Loose Soil. 2 M&L For Cement Concrete Type D2 Using 40Mm Graded Aggregate As In Foundations, Filling Mass Concrete Complete 3 M&L For Rcc M-25 Design Mix Using 20Mm Graded Aggregate As In Foundations, Including Rafts, Footings, Foundation Beams, Plinth Complete All As Specified And Directed By Engr-In-Charge. 4 M&L For Rcc M-25 Design Mix Using 20Mm Graded Aggregate As In Lintel, Beams Plinth Beam Complete All As Specified And Directed By Engr-In-Charge. 5 M&L For Rcc M-25 Design Mix Using 20Mm Graded Aggregate As In Columns Complete All As Specified And Directed By Engr-In-Charge. 6 M&L For Rcc M-25 Design Mix Using 20Mm Graded Aggregate As In Supported Slabs/Shelves Etc Complete All As Specified And Directed By Engr-In-Charge. 7 M&L For Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Better For Rough Finished Surface Complete 8 M&L For Formwork To Sides Of Beams, Lintels And Soffits (If Any) And Plinth Beams; And Similar Work; Vertical Or To Better For Rough Finished Surface Complete 9 M&L For Formwork To Sides Of Columns And Similar Work; Vertical Or To Better For Rough Finished Surface Complete 10 M&L For Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick (Horizontal Or Sloping) 11 M&L For Brick Work With Sub Class ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:6 12 M&L Tmt D Bars 10Mm Dia Over Cut To Length Bent To Shape Reqd, Incl Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips, Quality Confirming To Fe 410-S Or Fe 410-0. 13 M&L Tmt D Bars 5Mm Dia And Over Upto 10Mm Dia Cut To Length Bent To Shape Reqd, Incl Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips, As In Stirrups/Binder Complete All As Specified And Direced. 14 M&L 10Mm Thick Plaster In Cm (1:6) On Brick Or Concrete Surfaces Of Internal Walls Finished Even And Smooth Without Using Extra Cement 15 M&L 5Mm Thick Plaster In Cm (1:3) On Concrete/Brick Surfaces Of Ceilings. 16 M&L 15 Mm Thick Plaster In Cm (1:4) Finished Fair And Even On Brick/Concrete Surfaces On Ext External Surface Of Wall. 17 M&L Preparing New Wood Based Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Pink Primer. 18 M&L Preparing Newly Plastered Surfaces Of Wall And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Chalk Whiting Complete All As Specified And Directed 19 M&L For Preparing New Concrete/Wood Susrface Of Ceiling Of Any Description Or Otherwise And Applying Three Coats Of White Wash Complete All As Specified And Directed 20 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Over New Surfaces. 21 M&L For Pressed Steel Frames For Doors 105 X 60Mm With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete, As Specified, Supplied And Fixed In Position 22 M&L For Pressed Steel Frames For Doors 125 X 60Mm With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete, As Specified, Supplied And Fixed In Position 23 M & L For Pcc Type C-1 (1:3:6) Using 12.5Mm Graded Stone Aggregate As In Filling Of Hollow Pressed Steel Frame Etc Complete 24 S&F Glazed And Skeleton Shutters 30Mm Thick 2Nd Class Hw Open Rebated To Receive Glass Gauge Etc (With Or Without Sash Bars) Fitted With Cut And Mitred Breads For Securing Glass Etc Provided With Stiles And Rails, Sizes At Members Of Shutters As Specified In Ssr Part I, Sec 8, Clause 8.20(B). 25 S&F Flush Shutters, Solid Core 30Mm Thick With Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Kiln Seasoned And Chemically Pressure Treatred Completed All As Specied And Fixed In Position. 26 M&L For Aluminium Anodised 3 Track Slidding Window And Loured Type Ventilator Powder Coated Aluminium Sections Weighing 0.55 Kg/M Including With Aluminium Frame Necessary Joining Cleats, Glazing Clips, Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Includding All Necessary Fittings And Fixture Complete All As Specified And Directed By Engr-In-Charge. Note:- Glass Pane Will Be Measured And Paid Seperately 27 S&F Butt Hinges 100Mm Long Stainless Steel. 28 S&F Aluminium Tower Bolt 200Mm Long Of Anodised Section 29 S&F Anodised Aluminium Alloy Handles Cast Type, Each 150Mm Long 30 S&F Aluminium Alloy Anodized Sliding Door Bolt 300Mm Long With Hasp And Staple Fixing Clips Etc Complete. 31 S&F Pin Headed/Frosted Glass 4.0Mm Thick Type And Glazing In Square/Rectangular In Each Pane 32 M&L For Sheet Glass 4.80 Mm Thick Ordinary Quality And Glazing With Oil Putty In Square/Rectangular And Fixed With Aluminium Beads Or Putty Etc Complete All As Sspecified And Direcrted. 33 S&F Stainless Wire Mesh 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Wire Staple Wire In Door/ Window And Ventilator Complete I All As Directed. 34 M&L For Floor Door Stopper Aluminium Alloy Body And Tongue With Hard Drawn Steel Spring Of 140Mm Long And Fixed In Position Complete. 35 M&L For 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Including Roller Androller Plate Complete And Fixed In Position 36 M&L For Gi Tubes, Medium Grad, Galvanised, With All Fitting; Laid In Trenches/Floor Or Fixing With Roof Of 15 Mm Dia Complete All As Specified And Directed 37 M&L For Gi Tubes, Medium Grad, Galvanised, With All Fitting; Laid In Trenches/Floor Or Fixing With Roof Of 25 Mm Dia Complete All As Specified And Directed 38 S&F Pvc (Swr) Multi Floor Trap With Grating Including Jointing With Solvent Cement Of 75Mm Dia 39 Returning , Filling , Including Spreading , Levelling, Watering And Well Ramming In Layers Not Exc 25Cm All As Specified And Directed 40 Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point As Directed By Engr-In-Charge 41 M&L For Hardcore Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed 42 M&L For Pcc 1:4:8 Type D2 Using 40Mm Graded Aggregate 75Mm Thick As In Sub Base Complete All As Specified And Directed. 43 M&L For Moorum/Red Bajri Filling In Floors Or Pavings, Laid In Layers N Exc. 15 Cmthick, Spread, Levelled And Rammed Including Watering Complete All As Specified And Directed By Engr-In-Charge 44 Rotational Moulded Polye Thylene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Valve And Rod Nuts All As Specified In Ssr Part I Of 1000 Ltr Capacity 45 M&L For Backing Coat Of 10Mm Thick On Wall/Skirting To Receive The Tiles In Cm 1:4 Complete All As Specified And Directed. 46 M&L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick For Laying Floor Finishes In Cm 1:6 Complete All As Specified And Directed. 47 M&L For Acid Resistant Tiles 15Mm Thick Vitreous Ceramic, Unglazed, Set, Jointed And Pointed In Chemical Resistant Mortar, Resin Type, As In Floors/In Vertical Surface Complete All As Specified And Directed. 48 M&L For Glazed Earthen Ceramic Coloured Tiles Of Size 300X200X7Mm/450X200X7 Mm In Vertical Surface Such As Skirting/ Dado Over Screed Bed Or Bedding Layer 10 Mm Thick In Cm 1:4 Complete All As Specified And Directed. 49 M&L For Stainless Steel Curtain Rod Of 20Mm Dia Cut To Required Length And Fixed In Position Complete All As Specified And Directed By Engr-In-Charge. 50 S&F Stainless Steel Brackets Of 20Mm Dia For Curtain Rod And Fixed In Position Complete All As Specified And Directed By Engr-In-Charge 51 M&L For Anodised Aluminium Grill (Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/ Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer - In- Charge. 52 M&L For Treating The Bottom And Sides Of Excavation At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area Complete All As Specified And Directed By Enr-In-Charge. 53 M&L For Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) Complete All As Specified And Directed By Enr-In-Charge. 54 M&L For Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Complete All As Specified And Directed By Enr-In-Charge. 55 M&L For Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area Complete All As Specified And Directed By Enr-In-Charge. 56 M&L For Treating The Soil Along With External Perimeter Of Building At The Rate Of 2.25 Litre Of Emulsion Per Metre Of The Perimeter Wall Complete All As Specified And Directed By Enr-In-Charge. 57 S&F Pvc Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Bracket Flush Pipe And Fixed In Position Complete All As Specified And Directed 58 S&F For Bib Taps, Cast Copper Alloy Chromium Plated With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Of 15Mm Dia Complete 59 S&F Pillar Taps, Cast Copper Alloy, With Capstan Heads, Chromium Plated, Swan Nack Type Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed Of 15Mm Dia 60 S&F Stop Valves/Angle Cock, Cast Copper Alloy, Chromium Plated Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed Of 15Mm Dia 61 S&F Pvc Connection With Brass Socket On Both Side 45Cm To 60Cm For 15Mm Dia Pipe. 62 M&L For Pcc 1:3:6 Type C2 Using 40Mm Graded Aggregate As In Plinth Protection Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed 63 S&F Vitreous China Wash Down Water Closet Pan (Pedestal Pattern), White (Excluding Fixing Bolts, Flushing Cistern And Flush Pipe) Including Connection To Drain (Or Outgoing Pipe) And To Flushing Pipe, Antisyphonage Pipe, Etc..Complete Fixed In Position As Directed By Engr-In-Charge 64 S&F In Repair Viterous China Wash Basin, White Flat Back, Size 550X400Mm Oval Type Mounted On Granite Plateform Excluding Pillar Taps, But Including Waste Pipe, Couplings Complete All As Specified And Fixed In Position 65 S&F Waste Coupling Of 32 /40Mmmm Dia Bore Of Discharge Pipe 66 M&L For Pvc (Swr) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Of Dia 75Mm 67 S&F High Density Polyethylene Pipes(Hdpe) Of Pressure Rating 6 Kgf/Cm2 Of 32Mm Bore Fixed Complete To Walls,Ceilings Or In Floors Etc. 68 Supply And Fix Pvc (Swr) Pipes 110Mm Bore Single Socketed In Any Length With Rubber Ring Joint Fixed To Wall Complete All As Specified And Directed. 69 M&L Concrete Bed To Drain Pipes In Cement Concrete 1:3:6 Type C2, 150 Mm Bore Incl Packing Under And Hunching Against The Sides Of Pipe After They Are Laid And Teste Complete All As Specified And Directed 70 M&L For Re-Inforced Cencrete Pipe, Class Np-2 With One Collar Per Length Of 150Mm Dia And Fixed In Position Complette All As Specified And Directed. 71 M&L For Ahealth Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre To 2.00 Mtr Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified. 72 S&F Towel Rail 450Mm Long Of Ptmt Fixed With Including Chromium Plated Brass Screw And Wooden/Plastics Clits (170Gms) 73 S&F Looking Mirror Of Selected Quality Glass Mounted On 6Mm Thick Ac Building Board Or Commercial Ply Wood And Fixed To Wooden Plugs With Chromium Plated Screw Cup Washer Complete And Fixed In Position 74 S&F Sheet Glass Shelf Asambly Consisting Of 5.50Mm Thick Glass Sheet Shelf 12 Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long 75 S&F Pvc (Swr) Gully Trap 125/110 Mm, Setting And Jointing With Solve Complete Fixed In Position 76 S&F Urinal, Bowl Type Or Half Stall Pattern, Basin Only Including Connections To Flushing Pipe And Outgoing Pipes Fixed In Position Complete All As Specified And Directed. 77 M&L For Providing And Applying Plaster Of Paris Putty Of 1 Mm Thickness Over New Or Old Plastered Surface To Prepare The Surface Even And Smooth Complete All As Specified And Directed. 78 M&L For 20Mm Thick Plastering In Cm 1:4 Over Roof Surface To Obtain A Leveled Roof Surface Complete All As Specified And Directed. 79 M&L For Applying Evenly A Tack Coat/Priming Surfaces And Applying Industrial Bitumen 85/25 At The Rate Of 1.20 Kg/Sqm Includding Cleaning Roof Surface Complete All As Specified And Directed. 80 M&L For App Based Polymeric Membrane Minimum Weighing 3Kg/Sqm And Minimum 3Mm Thick Reinforced With Polyster Non Wove Fabric (Wt. Not Less Than 150 Gms/Sqm) Land On Primed Surface By Forced Application Complete All As Specified 81 M&L For Preparing New Surface Of Roof Treatment ( App Membrane) And Applying Two Coats Of Aluminium Paint Complete All As Specified And Directed. 82 M&L For Gun-Metal, Globe Or Gate Valves, Of 25Mm Dia With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed In Position Complete. 83 M&L For Ball Valves High Pressure Of Ptmt With Epoxy Of 25Mm Dia Coated Aluminium Rod & Highdensity Plastic Ball Screwed For Iron Pipe And Fixed. (Minimum Weight 15Mm-142Gms/ 2 0 M M - 2 1 0 G M S . / 25Mm-455Gms/ 40Mm - 690 Gms) 84 Surface Excavation N.Exc N. Exc 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft/Loose Soil Complete All As Specified And Directed. 85 Removing Excavated Material Exc. 50M But N. Exc 250 Mtr And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 86 M&L For Pcc 100 Mm Thick 1:4:8 Type D2 Using 40Mm Graded Aggregate Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 87 M&L For Chequered Cement Concrete Tiles 30Cm X 30Cm X 20 To 25Mm Thick, Set, Jointed And Pointed In Neat Cement Slurry With Grey Cement No Pigment In Floors And Fixed In Position Complete All As Specified And Directed. 88 M&L For Screed Bed Or Bedding Layer Of Mortar 20Mm Thick In Cm 1:6 For Laying Floor Finish Complete All As Specified And Directed. 89 M&L For Pcc 1:2:4 Type B0 Using 12.50Mm Graded Aggregate As In Coopings And The Like Including Weathering, Slightly Rounded Or Chamfered And Throating Complete All As Specified And Directed. 90 M&L For Plain Cement Concrete 1:4:8 Type D2 Using 40Mm Graded Aggregate As In Foundation Of Manholes Including Necessary Form Work Complete Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 91 M&L For Brick Work With Sub Class B Brick Straight Or Curved On Plan Exc 6 M Mean Radius And Built In Cm 1:4 Complete 92 M&L For Rendering 15Mm Thick On Faisr Faces Of Brick Masonary Surfce In Cm 1:4 Mixed With Integral Water Proofing Compound @ 3% By Weight Of Cement Fdfinished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 93 Supply Only Integral Water Proofing Compound Of Approved Make Complete All As Specified And Directed. 94 M&L For Pcc 1:2:4 Type B -1 Using 20 Mm Graded Aggregate As In Cover Slab Of Man Holes Including Necessary Form Work Ande Set In Cm 1:4 Complete All As Specified And Directed. 95 M&L For 150Mm Dia Reinforced Cement Concrete Pipe, Class Np3, Laid And Jointed Complete With Collar And Fixed In Position 96 M&L For Concrete Bed To Drain Pipes In Pcc 1:3:6 Type C2 Using 20Mm Graded Stone Aggregate Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested For 150Mm Dia Pipe And Fixed In Position Conplete All As Specified And Direced. 97 M&L For Cutting Into Existing Manholes For Connecting New Drains, Of 150Mm Dia Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required Complete All As Specified And Directed. 98 Dwemolition Of Reinforced Cement Concrete (Reinforcement Cut As Required To Facilitate For Demolition) Of Roof (Other Than Ground Floor) Beams Staircases, Landing Chajja;S And Similar Suspended Work Complete All As Specified And Directed 99 Dismantling Of Brick Tiles Or Terracing Tiles, Single Layer On Roofs Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Therof) Complete All As Specified And Directed.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. exc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in soft/loose soil. |
| 2 | M&L for Cement concrete type D2 using 40mm graded aggregate as in foundations, filling mass concrete complete |
| 3 | M&L for RCC M-25 Design Mix using 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams, plinth complete all as specified and directed by Engr-In-Charge. |
| 4 | M&L for RCC M-25 Design Mix using 20mm graded aggregate as in lintel, beams plinth beam complete all as specified and directed by Engr-In-Charge. |
| 5 | M&L for RCC M-25 Design Mix using 20mm graded aggregate as in Columns complete all as specified and directed by Engr-In-Charge. |
| 6 | M&L for RCC M-25 Design Mix using 20mm graded aggregate as in supported slabs/shelves etc complete all as specified and directed by Engr-In-Charge. |
| 7 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better for rough finished surface complete |
| 8 | M&L for Formwork to sides of beams, lintels and soffits (if any) and plinth beams; and similar work; vertical or to better for rough finished surface complete |
| 9 | M&L for Formwork to sides of Columns and similar work; vertical or to better for rough finished surface complete |
| 10 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 11 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 |
| 12 | M&L TMT d bars 10mm dia over cut to length bent to shape reqd, incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality confirming to Fe 410-S or Fe 410-0. |
| 13 | M&L TMT d bars 5mm dia and over upto 10mm dia cut to length bent to shape reqd, incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, as in stirrups/binder complete all as specified and direced. |
| 14 | M&L 10mm thick plaster in CM (1:6) on brick or concrete surfaces of internal walls finished even and smooth without using extra cement |
| 15 | M&L 5mm thick plaster in CM (1:3) on concrete/brick surfaces of ceilings. |
| 16 | M&L 15 mm thick plaster in CM (1:4) finished fair and even on brick/concrete surfaces on ext external surface of wall. |
| 17 | M&L preparing new wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer. |
| 18 | M&L preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed |
| 19 | M&L for preparing new concrete/wood susrface of ceiling of any description or otherwise and applying three coats of white wash complete all as specified and directed |
| 20 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 21 | M&L for Pressed steel frames for doors 105 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed in position |
| 22 | M&L for Pressed steel frames for doors 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed in position |
| 23 | M & L for PCC type C-1 (1:3:6) using 12.5mm graded stone aggregate as in filling of hollow pressed steel frame etc complete |
| 24 | S&F glazed and skeleton shutters 30mm thick 2nd class HW open rebated to receive glass gauge etc (with or without sash bars) fitted with cut and mitred breads for securing glass etc provided with stiles and rails, sizes at members of shutters as specified in SSR Part I, Sec 8, clause 8.20(b). |
| 25 | S&F Flush shutters, solid core 30mm thick with construction, with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treatred completed all as specied and fixed in position. |
| 26 | M&L for Aluminium anodised 3 track slidding window and loured type ventilator powder coated aluminium sections weighing 0.55 kg/m including with aluminium frame necessary joining cleats, glazing clips, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised includding all necessary fittings and fixture complete all as specified and directed by Engr-In-Charge. NOTE:- glass pane will be measured and paid seperately |
| 27 | S&F butt hinges 100mm long stainless steel. |
| 28 | S&F aluminium tower bolt 200mm long of anodised section |
| 29 | S&F Anodised aluminium alloy handles cast type, each 150mm long |
| 30 | S&F aluminium alloy anodized sliding door bolt 300mm long with hasp and staple fixing clips etc complete. |
| 31 | S&F pin headed/frosted glass 4.0mm thick type and glazing in square/rectangular in each pane |
| 32 | M&L for Sheet Glass 4.80 mm thick ordinary quality and glazing with oil putty in square/rectangular and fixed with aluminium beads or putty etc complete all as sspecified and direcrted. |
| 33 | S&F Stainless wire Mesh 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with wire staple wire in door/ window and ventilator complete I all as directed. |
| 34 | M&L for floor door stopper aluminium alloy body and tongue with hard drawn steel spring of 140mm long and fixed in position complete. |
| 35 | M&L for 300mm, ordinary rat tail rod pattern springs including roller and including roller androller plate complete and fixed in position |
| 36 | M&L for GI Tubes, Medium grad', galvanised, with all fitting; laid in trenches/floor or fixing with roof of 15 mm dia complete all as specified and directed |
| 37 | M&L for GI Tubes, Medium grad', galvanised, with all fitting; laid in trenches/floor or fixing with roof of 25 mm dia complete all as specified and directed |
| 38 | S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement of 75mm dia |
| 39 | Returning , filling , including spreading , levelling, watering and well ramming in layers not exc 25cm all as specified and directed |
| 40 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as directed by Engr-in-Charge |
| 41 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 42 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate 75mm thick as in sub base complete all as specified and directed. |
| 43 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cmthick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-Charge |
| 44 | Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including valve and rod nuts all as specified in SSR Part I of 1000 Ltr capacity |
| 45 | M&L for backing coat of 10mm thick on wall/skirting to receive the tiles in CM 1:4 complete all as specified and directed. |
| 46 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed. |
| 47 | M&L for Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, as in floors/in vertical surface complete all as specified and directed. |
| 48 | M&L for glazed earthen ceramic coloured tiles of size 300x200x7mm/450x200x7 mm in vertical surface such as skirting/ dado over Screed bed or bedding layer 10 mm thick in cm 1:4 complete all as specified and directed. |
| 49 | M&L for Stainless steel curtain rod of 20mm dia cut to required length and fixed in position complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F Stainless steel Brackets of 20mm dia for curtain rod and fixed in position complete all as specified and directed by Engr-in-Charge |
| 51 | M&L for anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer - in- Charge. |
| 52 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Enr-in-Charge. |
| 53 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Enr-in-Charge. |
| 54 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Enr-in-Charge. |
| 55 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Enr-in-Charge. |
| 56 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Enr-in-Charge. |
| 57 | S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket flush pipe and fixed in position complete all as specified and directed |
| 58 | S&F for Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of 15mm dia complete |
| 59 | S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, Swan nack type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of 15mm dia |
| 60 | S&F Stop valves/Angle Cock, cast copper alloy, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of 15mm dia |
| 61 | S&F PVC connection with brass socket on both side 45cm to 60cm for 15mm dia pipe. |
| 62 | M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed |
| 63 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc..complete fixed in position as directed by Engr-In-Charge |
| 64 | S&F in repair viterous china wash basin, white flat back, size 550x400mm oval type mounted on granite plateform excluding pillar taps, but including waste pipe, couplings complete all as specified and fixed in position |
| 65 | S&F waste coupling of 32 /40mmmm dia bore of discharge pipe |
| 66 | M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement of dia 75mm |
| 67 | S&F High density polyethylene pipes(HDPE) of pressure rating 6 kgf/cm2 of 32mm bore fixed complete to walls,ceilings or in floors etc. |
| 68 | Supply and fix PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joint fixed to wall complete all as specified and directed. |
| 69 | M&L concrete bed to drain pipes in cement concrete 1:3:6 type C2, 150 mm bore incl packing under and hunching against the sides of pipe after they are laid and teste complete all as specified and directed |
| 70 | M&L for re-inforced cencrete pipe, class NP-2 with one collar per length of 150mm dia and fixed in position complette all as specified and directed. |
| 71 | M&L for AHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre to 2.00 mtr long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 72 | S&F towel rail 450mm long of PTMT fixed with including chromium plated brass screw and wooden/plastics clits (170gms) |
| 73 | S&F looking mirror of selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated screw cup washer complete and fixed in position |
| 74 | S&F sheet glass shelf asambly consisting of 5.50mm thick glass sheet shelf 12 cm wide with chromium plated bracket guard and railing 60cm long |
| 75 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solve complete fixed in position |
| 76 | S&F Urinal, bowl type or half stall pattern, basin only including connections to flushing pipe and outgoing pipes fixed in position complete all as specified and directed. |
| 77 | M&L for Providing and applying plaster of paris putty of 1 mm thickness over new or old plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 78 | M&L for 20mm thick plastering in CM 1:4 over Roof surface to obtain a leveled roof surface complete all as specified and directed. |
| 79 | M&L for applying evenly a tack coat/Priming surfaces and applying industrial bitumen 85/25 at the rate of 1.20 Kg/Sqm includding cleaning roof surface complete all as specified and directed. |
| 80 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified |
| 81 | M&L for preparing new surface of Roof treatment ( APP Membrane) and applying two coats of aluminium paint complete all as specified and directed. |
| 82 | M&L for Gun-metal, globe or gate valves, of 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed in position complete. |
| 83 | M&L for Ball valves high pressure of PTMT with epoxy of 25mm dia coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) |
| 84 | Surface excavation n.exc n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 85 | Removing excavated material exc. 50m but n. exc 250 mtr and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 86 | M&L for PCC 100 mm thick 1:4:8 type D2 using 40mm graded aggregate finished even and smooth without using extra cement complete all as specified and directed. |
| 87 | M&L for Chequered cement concrete tiles 30cm x 30cm x 20 to 25mm thick, set, jointed and pointed in neat cement slurry with grey cement no pigment in floors and fixed in position complete all as specified and directed. |
| 88 | M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finish complete all as specified and directed. |
| 89 | M&L for PCC 1:2:4 type B0 using 12.50mm graded aggregate as in coopings and the like including weathering, slightly rounded or chamfered and throating complete all as specified and directed. |
| 90 | M&L for Plain cement Concrete 1:4:8 type D2 using 40mm graded aggregate as in foundation of manholes including necessary form work complete Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 91 | M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius and built in CM 1:4 complete |
| 92 | M&L for rendering 15mm thick on faisr faces of brick masonary surfce in CM 1:4 mixed with integral water proofing compound @ 3% by weight of cement fdfinished even and smooth without using extra cement complete all as specified and directed. |
| 93 | Supply only Integral water proofing compound of approved make complete all as specified and directed. |
| 94 | M&L for PCC 1:2:4 type B -1 using 20 mm graded aggregate as in cover slab of man holes including necessary form work ande set in CM 1:4 complete all as specified and directed. |
| 95 | M&L for 150mm dia Reinforced cement concrete pipe, class NP3, laid and jointed complete with collar and fixed in position |
| 96 | M&L for Concrete bed to drain pipes in PCC 1:3:6 type C2 using 20mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia pipe and fixed in position conplete all as specified and direced. |
| 97 | M&L for Cutting into existing manholes for connecting new drains, of 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 98 | Dwemolition of Reinforced cement concrete (Reinforcement cut as required to facilitate for demolition) of roof (other than ground floor) beams staircases, landing chajja;s and similar suspended work complete all as specified and directed |
| 99 | Dismantling of brick tiles or terracing tiles, single layer on roofs any thickness, including plastering and leeping (whether full thickness removed or only a part therof) complete all as specified and directed. |
| 100 | Dismantling structural steel work including doors, gates, grill or window but excluding frames truss etc complete all as specified and directed |
| 101 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame n. exc 1.50 Sqm each complete all as specified and directed |
| 102 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame exc 1.50 Sqm but n. exc 4.00 Sqm each complete all as specified and directed |
| 103 | Excavation over areas n exc 1.50 mtr deep and fgetting out in hard/dense soil of bldg of any type complete all as specified |
| 104 | Removing excavated material exc 1.50 KM but n. exc 5.0 KM and depositing whee directed. |
| 105 | Demolition and breaking up drain pipes size 100 - 150mm PVC, SWG, AC or RCC pipes of fnay description including fittings complete all as specified |
| 106 | Dismantling of Bib Tabs , pillar tabs of any type and size fixed in iron pipe complete all as specified |
| 107 | Dismantling of gate valve of any type and size complete all as specifed |
| 108 | Dismantling of CP stop cock/angle cock fixed in iron pipe complete all as specified |
| 109 | Taking down steel tubing of 15mm dia and connections, including leaning for reefixing or removal to store as complete all as specified |
| 110 | Dismantling water tanks of 500 Ltr capacity complete all as specified and directed |
| 111 | Taking down steel tubing of 20 mm dia and connections, including leaning for reefixing or removal to store as complete all as specified |
| 112 | Taking down carefully (aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block, etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 113 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to MES store yard. |
| 114 | Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store |
| 115 | Taking down and refixing of old old sheet metal enclosure, switch, fuse unit, TPN Box, distribution board any size / type/ way/ capacity including fuses MCBs, insulator RCCBs etc complete after removing all connection and making good the disturbed surface all as directed by Engg-in-charge. |
| 116 | Taking down carefully (aluminium) submain wiring complete of any type (batten/surface conduit or concealed) all as specified and directed. |
| 117 | Dismantling and taking down old Earthing with all connecting acessories. |
| 118 | Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose. |
| 119 | M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed Please Enable Macros to View BoQ information |
| 120 | M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender