Tender For The Installation Of Air Conditioner And Associated Electrical Wiring Work In The District Judge And Additional District Judge Courts And Chambers In Mirzapur District.
Tender Overview
Project Description
Tender For The Installation Of Air Conditioner And Associated Electrical Wiring Work In The District Judge And Additional District Judge Courts And Chambers In Mirzapur District.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Jul-2026 | Corrigendum | Date | 27-Jul-2026 |
| 2 | 27-Jul-2026 | Corrigendum for Date | Date | 01-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | A.C.Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 0C (out door ambient temperature).1.5 TR with 5 Star BEE Rating(AC MAKE NAME- CARRIER/LG/BLUE STAR/ PANASONIC) |
| 2 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 0C (out door ambient temperature).2 TR with 5 Star BEE Rating(AC MAKE NAME- CARRIER/LG/BLUE STAR/ PANASONIC) |
| 3 | S/F of 4KVA Voltage Stablizer for 1.5 Ton A.C (130-280 volt) sigle phase copper winding Make -Servokon make |
| 4 | S/F of 5KVA Voltage Stablizer for 2.0 Ton A.C (130-280 volt) sigle phase copper winding Make -Servokon make |
| 5 | S/F of Suction/Discharge copper pipe line in split AC unit 1.5 ton capacity including brazing, nitile rubber insulation 9mm thick class\\"O\\" etc complete 1/4\\" (6.40mm) &1/2\\"(12.70 mm) |
| 6 | S/F of Suction/Discharge copper pipe line in split AC unit 2.0ton capacity including brazing, nitile rubber insulation 9mm thick class\\"O\\" etc complete 3/8\\" (9.50mm &5/8\\"(15.90 mm) |
| 7 | S/F of Control cable2.5SQMM 4 CORE ROUND COPPERCABLE FOR STABLIZER TO INDOOR UNIT TO OUTDOOR UNIT |
| 8 | S/F of Control cable2.5SQMM 3 CORE ROUND COPPER CABLE FOR STABLIZER TO INDOOR UNIT |
| 9 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply 20 mm nominal dia Pipes |
| 10 | S/F of MS Angle Stand for Outdoor unit of Split A.C. P.S No- Market rate |
| 11 | Supply Fabrication and installation of M.S cage for protection of outdoor unit from animal /theft L*W*H 1300 mm*600 mm*1200 mm complete in all respect |
| 12 | WIRING & PANELSupplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including. connections, painting etc. as required. Each (Make - Havells/ Anchor/ Legrand) DSR 1.57 |
| 13 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24) Double door (Make - L&T/Havells/ Anchor/ Legrand) DSR 2.5.2 |
| 14 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12) Double door (Make - L&T/Havells/ Anchor/ Legrand) DSR 2.5.1 |
| 15 | S&F of 63 Amp 4 pole MCCB(25 kA) Thermal Magnetic release(Make - Havells/ Anchor/ Legrand) (AR) |
| 16 | S&F of 100 Amp 4 pole MCCB(25 KA) Thermal Magnetic release A (Make - Havells/ Anchor/ Legrand) DSR 2.2.13 |
| 17 | S&F of 6-32Amp Single pole MCB (10 kA ) C curve (Make - Havells/ Anchor/ Legrand) DSR 2.10.1 |
| 18 | Supply and wiring of submain with two number 6 sq. mm PVC Insulated 25 mm dia heavy duty (2 mm thick) PVC conduit with one No.6 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn tncondu on surface complete in all respect (Make - Havells/Anchor /Plycab DSR 1.14.4 |
| 19 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-lncharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.400 sq. mm 3-1/2 core P.Sno-501,t (Make - RR/Havells/ Anchor/ Polycab) S.No. 2a.1.20 |
| 20 | 150sq. mm 3-1/2 core (Make - RR/Havells/ Anchor/ Polycab) S.No. 20a.1.16 |
| 21 | 120sq. mm 3-1/2 core (Make - RR/Havells/ Anchor/ Polycab) S.No. 20a.1.15 |
| 22 | 70sq. mm 3-1/2 core (Make - RR/Havells/ Anchor/ Polycab) S.No. 20a.1.13 |
| 23 | 50 sq. mm 3-1/2 core (Make - RR/Havells/ Anchor/ Polycab) S.No. 20a.1.12 |
| 24 | 35 sq. mm 3-1/2 core (Make - RR/Havells/ Anchor/ Polycab) S.No. 20a.1.11 |
| 25 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-lncharge. Size- 400 sq. mm 3-1/2 core (Make -Havells/ Anchor/Dowells) DSR 2131 |
| 26 | 150sq. mm 3-1/2 core (Make - Dowells or equivalent) DSR 2126 |
| 27 | 120sq. mm 3-1/2 core (Make - Dowells or equivalent) DSR 2125 |
| 28 | 70sq. mm 3-1/2 core (Make - Dowells or equivalent) DSR 2123 |
| 29 | 50sq. mm 3-1/2 core (Make - Dowells or equivalent) DSR 2122 |
| 30 | 35 sq. mm 3-1/2 core (Make - Dowells or equivalent) DSR 2121 |
| 31 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-lncharg Size400 Sqmm P.S no-504 o (Make - Dowells orequivalent) DSR 2215 |
| 32 | Size-240Sqmm (Make - Dowells or equivalent) DSR 2213 |
| 33 | Size-150 Sqmm (Make - Dowells or equivalent) DSR 2210 |
| 34 | Size-120 Sqmm (Make - Dowells or equivalent) DSR 2209 |
| 35 | Size-70 Sqmm (Make - Dowells or equivalent) DSR 2207 |
| 36 | Size-50 Sqmm (Make - Dowells or equivalent) DSR 2206 |
| 37 | Size-35 Sqmm (Make - Dowells or equivalent) DSR 2205 |
| 38 | Size-25 Sqmm (Make - Dowells or equivalent) DSR 2204 |
| 39 | supply and Fabrication factory fabricated 6 wired met ciad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4PoIe Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B Only .I./C 630 Amp mccb - 1no ,O/G 200Amp MCCB-2Nos 100Amp MCCB-1Nos 63 Amp -2 no 20.1.4(b) MAIN LT PANEL S.No. 20.1.4(b) |
| 40 | supply and Fabrication factory fabricated 6 wired met ciad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4PoIe Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B Only .I./C 200Amp ,O/G 63 Amp-4Nos (for Senior Division Court Building) (AR) |
| 41 | supply and Fabrication factory fabricated 6 wired met ciad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4PoIe Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B Only .I./C 200Amp ,O/G 100Amp-1Nos 63Amp-2Nos switch (for ADJ SC/ST Court Building) (AR) |
| 42 | supply and Fabrication factory fabricated 6 wired met ciad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4PoIe Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B Only .I./C 100Amp ,O/G 63Amp-2 Nos FTC COURT BUILDING S.No. 20.1.1(a) |
| 43 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 5.4 |
| 44 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR 5.16 |
| 45 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 |
| 46 | Costruction of Panel Room by providing of all construction related materials Room size 4mtr x 5 mtr PS NO-Plinth area rate 2023(1.1.1) DSR 1.1.1 (Civil) |
| 47 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. DSR 9.83 |
| 48 | Supply & Fixing of 630 Amp on load change over switch (AR) |
| 49 | Supply & Fixing Of co2 based wheeled fire extingusher 6.5 kg (AR) |
| 50 | Supply fixing of 4mm thick ACP sheet to cover opening in Court Room DSR 2021 code no-2631rate analysis (CPWD rate/1.12)-15%+10%+(10% Labour chages) DSR 2631 |
| 51 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender