Housing Urban and Rular Development Government Departments Closing in 10 days TDR #56401143

Tender For The Installation Of Ac Units And Associated Electrical Wiring In The District Judge And Additional District Judge Courts And Chambers In Chandauli District.

Issued by Government Departments · Chandauli, Uttar Pradesh
Tender Value
76 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
10 days left
EMD
5.80 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandauli → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For The Installation Of Ac Units And Associated Electrical Wiring In The District Judge And Additional District Judge Courts And Chambers In Chandauli District.

BOQ

Name of Work:- JANPAD CHANDAULI STITH JANPAD NYAYADHISH AVAM APAR JANPAD NYAYADHISH COURT AVAM CHAMBER ME AC STHAPIT KIYE JANE TATHA SAMBANDHIT VIDYUT WIRING KA KARYA.
Sl. No. Item Description
1AC INSTALLATIONSupplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 Degree Celcius (out door ambient temperature). Inverter Type - Cooling only - 1.5 TR with 5 Star BEE Rating make - Carrier/LG/Bluestar/ panasonic
2Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 Degree Celcius (out door ambient temperature). Inverter Type - Cooling only - 2.0 TR with 5 Star BEE Rating make - Carrier/LG/Bluestar/ panasonic
3SITC of 4 kVA Automatic Voltage Stabilizer (130-280V) Copper Winding
4SITC of 5 kVA Automatic Voltage Stabilizer (130-280V) Copper Winding
5Supply and Laying of 2.5 Sq mm 4 Core round copper cable for indoor unit to outdoor unit
6Supply and Laying of 2.5 Sq mm 3 Core round copper cable for stabilizer to indoor unit
7SITC of Suction/ Discharge both copper pipe line in split AC unit 1.5 Ton capacity including brazing, nitrile rubber insulation 6mm thick class 'O' etc. complate 1/4\\" (6.40mm) and 1/2\\" (12.70mm)
8SITC of Suction/ Discharge both copper pipe line in split AC unit 1.8/ 2.0 Ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc. complate 3/8\\" (9.50mm) and 5/8\\" (15.90mm)
9Supply and Laying of Heavy Duty PVC Plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessories complete
10Supply and Fixing of outdoor unit stand for split type ACs
11PART-B (WIRING)S/f DP Sheet enclosure on surface/recess along with 25/32A 240V \\"C\\" curve DP MCB complete with connection,s testing and commissioning etc. as required. DRS 2.16
12Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door (Tahsil Parisar 3 Nos+BSA Parisar 3 Nos) DSR 2.5.1
13Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 30 KA,FPMCCB DSR 2.2.1
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (Tahsil Parisar 31 Nos+BSA Parisar 25 Nos) DSR 2.10.1
15Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor multistrand, single core cable in surface/ recessed medium class PVC conduit as required MS. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (From Panel to DB) DSR 1.14.4
16SITC of LT Panel vemin proof floor mounting, MS Chanel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer-in-charge after proper sheet treatment process of shet steel, The bus bar of panel shall be of Electrical grade High conductive Al.alloy of appropriate cross section as per rating The main bus bar shall non throughout the panel of rating as main incomer rating, The Bus bar staff be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interest ot ensure the bear the jercks of short Circuit of 50kA for panels having ACB as incomer & 36kA for panels having MCCB incomers. panel shall be constructed in fully segregateed Compartment Design for Each Feeder as per 3b construction Formate The panel shall be completed in all respect Incoming: 200 Amp. MCCB-1 No Outgoing: 63 Amp.MCCB- 3 Nos. S.No.20.1.2(b)(ii)
17S/l of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on wall surface as directed by Engineer-Incharge, complete in all respect including excavation and refitting. The armouring of the cable shall be peroperly connected with the earth conductor by clamps etc, 120sqmm 3½ Core, (from Transformer to panel) S.No.20c.1.15
18S/l of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on wall surface as directed by Engineer-Incharge, complete in all respect including excavation and refitting. The armouring of the cable shall be peroperly connected with the earth conductor by clamps etc, 50sqmm 3½ Core, (200 Mtr for Tahsil Parisar & 100 mtr BSA Parisar) S.No.20c.1.12
19Brass Compression gland for (82mm) 3½x240sq. Mm 1.1kV grade cable DSR 2129
20Brass Compression gland for (50mm) 3½x50sq. Mm 1.1kV grade cable DSR 2122
21Aluminium lugs for 25sq. Mm cable DSR 2204
22Aluminium lugs for 50sq. Mm cable DSR 2206
23Aluminium lugs for 120sq. Mm cable DSR 2209
24Aluminium lugs for 240sq. Mm cable DSR 2213
25S&F of 200 AMP four pole Mouled case type on load change over switch with enclosure including the cost of labour, T & P and material reuired for proper completion of the work as per direction and satisfaction of Engineer an charge. (AR)
26Earthing with copper earth plate 600 mm x 600 mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arragnment and watering pipe of 2.7 metre long etc with charcoal/coke and salf as required.(Tahsil Parisar 5 Nos+BSA Parisar 4 Nos) DSR 5.6
27S/l of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) DSR 5.8
28GST @ 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56401143
AUTHORITY Government Departments
TENDER VALUE 76 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Public Works Department
Work Description Tender For The Installation Of Ac Units And Associated Electrical Wiring In The District Judge And Additional District Judge Courts And Chambers In Chandauli District.
Basic Detail
Tender No 1113/Nivida suchna(vns)-44/2026-27 Dt. 25.06.2026
Bidding Type Tender
Location
City Chandauli
State Uttar Pradesh
Key Dates
Publish Date 09 Jul 2026
Submission Date 21 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 76 Lakhs
Tender Fee 2354
EMD 5.80 Lakhs
Exemption Not Available
Document List
a483e0ab-cf8c-4d65-96d2-faddac2c67b1.html
BOQ_2190606.xls
Tendernotice_1.pdf
Tendernotice_2 (3).pdf
Tendernotice_3 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

a483e0ab-cf8c-4d65-96d2-faddac2c67b1.html

xls

BOQ_2190606.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (3).pdf

pdf

Tendernotice_3 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders