Tender For The Installation Of Ac Units And Associated Electrical Wiring In The District Judge And Additional District Judge Courts And Chambers In Chandauli District.
Tender Value
76 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
10 days left
EMD
5.80 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandauli → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For The Installation Of Ac Units And Associated Electrical Wiring In The District Judge And Additional District Judge Courts And Chambers In Chandauli District.
BOQ
| Sl. No. | Item Description |
| 1 | AC INSTALLATIONSupplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 Degree Celcius (out door ambient temperature). Inverter Type - Cooling only - 1.5 TR with 5 Star BEE Rating make - Carrier/LG/Bluestar/ panasonic |
| 2 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 Degree Celcius (out door ambient temperature). Inverter Type - Cooling only - 2.0 TR with 5 Star BEE Rating make - Carrier/LG/Bluestar/ panasonic |
| 3 | SITC of 4 kVA Automatic Voltage Stabilizer (130-280V) Copper Winding |
| 4 | SITC of 5 kVA Automatic Voltage Stabilizer (130-280V) Copper Winding |
| 5 | Supply and Laying of 2.5 Sq mm 4 Core round copper cable for indoor unit to outdoor unit |
| 6 | Supply and Laying of 2.5 Sq mm 3 Core round copper cable for stabilizer to indoor unit |
| 7 | SITC of Suction/ Discharge both copper pipe line in split AC unit 1.5 Ton capacity including brazing, nitrile rubber insulation 6mm thick class 'O' etc. complate 1/4\\" (6.40mm) and 1/2\\" (12.70mm) |
| 8 | SITC of Suction/ Discharge both copper pipe line in split AC unit 1.8/ 2.0 Ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc. complate 3/8\\" (9.50mm) and 5/8\\" (15.90mm) |
| 9 | Supply and Laying of Heavy Duty PVC Plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessories complete |
| 10 | Supply and Fixing of outdoor unit stand for split type ACs |
| 11 | PART-B (WIRING)S/f DP Sheet enclosure on surface/recess along with 25/32A 240V \\"C\\" curve DP MCB complete with connection,s testing and commissioning etc. as required. DRS 2.16 |
| 12 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door (Tahsil Parisar 3 Nos+BSA Parisar 3 Nos) DSR 2.5.1 |
| 13 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 30 KA,FPMCCB DSR 2.2.1 |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (Tahsil Parisar 31 Nos+BSA Parisar 25 Nos) DSR 2.10.1 |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor multistrand, single core cable in surface/ recessed medium class PVC conduit as required MS. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (From Panel to DB) DSR 1.14.4 |
| 16 | SITC of LT Panel vemin proof floor mounting, MS Chanel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer-in-charge after proper sheet treatment process of shet steel, The bus bar of panel shall be of Electrical grade High conductive Al.alloy of appropriate cross section as per rating The main bus bar shall non throughout the panel of rating as main incomer rating, The Bus bar staff be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interest ot ensure the bear the jercks of short Circuit of 50kA for panels having ACB as incomer & 36kA for panels having MCCB incomers. panel shall be constructed in fully segregateed Compartment Design for Each Feeder as per 3b construction Formate The panel shall be completed in all respect Incoming: 200 Amp. MCCB-1 No Outgoing: 63 Amp.MCCB- 3 Nos. S.No.20.1.2(b)(ii) |
| 17 | S/l of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on wall surface as directed by Engineer-Incharge, complete in all respect including excavation and refitting. The armouring of the cable shall be peroperly connected with the earth conductor by clamps etc, 120sqmm 3½ Core, (from Transformer to panel) S.No.20c.1.15 |
| 18 | S/l of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on wall surface as directed by Engineer-Incharge, complete in all respect including excavation and refitting. The armouring of the cable shall be peroperly connected with the earth conductor by clamps etc, 50sqmm 3½ Core, (200 Mtr for Tahsil Parisar & 100 mtr BSA Parisar) S.No.20c.1.12 |
| 19 | Brass Compression gland for (82mm) 3½x240sq. Mm 1.1kV grade cable DSR 2129 |
| 20 | Brass Compression gland for (50mm) 3½x50sq. Mm 1.1kV grade cable DSR 2122 |
| 21 | Aluminium lugs for 25sq. Mm cable DSR 2204 |
| 22 | Aluminium lugs for 50sq. Mm cable DSR 2206 |
| 23 | Aluminium lugs for 120sq. Mm cable DSR 2209 |
| 24 | Aluminium lugs for 240sq. Mm cable DSR 2213 |
| 25 | S&F of 200 AMP four pole Mouled case type on load change over switch with enclosure including the cost of labour, T & P and material reuired for proper completion of the work as per direction and satisfaction of Engineer an charge. (AR) |
| 26 | Earthing with copper earth plate 600 mm x 600 mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arragnment and watering pipe of 2.7 metre long etc with charcoal/coke and salf as required.(Tahsil Parisar 5 Nos+BSA Parisar 4 Nos) DSR 5.6 |
| 27 | S/l of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) DSR 5.8 |
| 28 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender