Tender for Repair & Replacement Of Lt Ug Cable Connected Lt Swith Gear System With External Light Fittings And Allied Works At Army Area Under Ge Avadi
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc complete all as specified and as directed. |
| 2 | Removing excavated material(soil)not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 3 | Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each complete all as specified and as directed. |
| 4 | Laying in trenches fine sieved excavated dry soil including spreading/leveling, cushioning for underground cables complete all as specified and as directed. |
| 5 | Supply and laying of common burnt clay building bricks, sub class B size for cable protection complete all as specified and as directed. |
| 6 | Material and labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5/4 in replacement of the following sizes cross-sectionl area including taking down of old unserviceable cable/OH line ACSR conductor of any type complete all as specified and as directed.:- (Note: Earth work and connected items will be measured and paid separately under respective items of schedule) for 10 sq mm 2 core |
| 7 | All the as per item no 6.00 here in before but for 16 sq mm 4 core |
| 8 | All the as per item no 6.00 here in before but for 25 sq mm 3.5/4 core |
| 9 | All the as per item no 6.00 here in before but for 35 sq mm 3.5 Core |
| 10 | All the as per item no 6.00 here in before but for 50 sq mm 3.5 Core |
| 11 | All the as per item no 6.00 here in before but for 70 sq mm 3.5 Core |
| 12 | All the as per item no 6.00 here in before but for 95 sq mm 3.5 Core |
| 13 | All the as per item no 6.00 here in before but for 120 sq mm 3.5 Core |
| 14 | All the as per item no 6.00 here in before but for 185 sq mm 3.5 Core |
| 15 | Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of following sizes complete all as specified and as directed. : (Note: Earth work and connected items will be measured and paid separately under respective items of schedule) for LT UG Cable 4 core 16 Sqmm |
| 16 | All as per item no 15.00 here in before but for LT UG Cable 3.5/ 4 core 25 Sqmm to 3.5 core 50 Sqmm |
| 17 | All as per item no 15.00 here in before but for LT UG Cable 3.5 core 70 Sqmm to 3.5 core 120 Sqmm |
| 18 | All as per item no 15.00 here in before but for LT UG Cable 3.5 core 150 Sqmm to 3.5 core 185 Sqmm |
| 19 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1.1 KV LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and as directed.Note: (a) Excavation,earth work,cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Material and labour for emergency maintenance work of LT cable line during breakdown by deploying skilled electricians at faulty site including transportation and other tools and plant required at site for fault rectification.(c) Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of breakdown and start attending breakdown within two hours, a penalty of Rs 600 per fault per hour shall be imposed over contractor and shall be deduct from his dues. |
| 20 | Supply and Fixing of Straight through joints heat shrink type for underground cable suitable for LT XLPE/ PVC sheathed/ armoured heavy duty cables with aluminium conductor complete all as specified and as directed of following sizes:- for 3.5/ 4 core, 16 sqmm to 50 sqmm |
| 21 | All as per item no 20.00 here in before but for 3.5/ 4 core, 70 sqmm to 120 sqmm |
| 22 | All as per item no 20.00 here in before but for 3.5/ 4 core, 150 sqmm to 185 sqmm |
| 23 | Material and labour for GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of following sizes including taking down old unserviceable one complete and all as specified and directed For Bore of tube 40mm |
| 24 | All as per item no 23.00 here in before but for Bore of tube 50mm |
| 25 | All as per item no 23.00 here in before but for Bore of tube 80mm |
| 26 | M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm including incommer MCCB 300 Amp 4 Pole, 36 KA of make Havells/ Schneider/ Siemens,The panel made out of 3.5 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.60 mtr high from ground level and 0.40 M below the ground level complete all as specified and as directed.. Note : Contractor is responsible to produce drawing and take approval before placing order. |
| 27 | M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm including incommer MCCB 250 Amp 4 Pole, 36 KA of make Havells/ Siemens/ Schneider ,The panel made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.60 mtr high from ground level and 0.40 M below the ground level complete all as specified and as directed.. Note : Contractor is responsible to produce drawing and take approval before placing order. Please Enable Macros to View BoQ information |
| 28 | M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm including incommer MCCB 250 Amp 4 Pole, 36 KA of make Havells/ Siemens/ Schneider ,The panel made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.60 mtr high from ground level and 0.40 M below the ground level complete all as specified and as directed.. Note : Contractor is responsible to produce drawing and take approval before placing order. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender