Agriculture Boards / Undertakings / PSU Closing in 8 days TDR #56399645

Tender For annual repair maintenance Electrical Works At Fci Fsd Ramanathapuram For The Year 2026-27. Sh: Replcement Of Damaged Underground Cables And Submersible Pumpset Along With Allied Works

Issued by Boards / Undertakings / PSU · Ramanathapuram, Tamil Nadu
Tender Value
8.12 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
8 days left
EMD
16260
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ramanathapuram → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair maintenance Electrical Works At Fci Fsd Ramanathapuram For The Year 2026-27. Sh: Replcement Of Damaged Underground Cables And Submersible Pumpset Along With Allied Works

BOQ

Name of Work:- ARMO Electrical works at FCI FSD Ramanathapuram for the year 2026-27. SH: Replcement of damaged underground cables and submersible pumpset along with allied works
Sl. No. Item Description
1Supplying of PVC insulated, PVC sheathed / XLPE aluminium conductor armoured under ground power cable of 1.1 KV grade conforming to IS 1554 part-I/7098(part-I) 1998 with up to date amendments of the following sizes.(a) 4 x 35 sq mm
2Supplying of PVC insulated, PVC sheathed / XLPE aluminium conductor armoured under ground power cable of 1.1 KV grade conforming to IS 1554 part-I/7098(part-I) 1998 with up to date amendments of the following sizes.(b) 4 x 25 sq mm
3Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(a) 100 mm dia
4Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required.
5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a) Up to 35 sq mm
6Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE armoured U G power cable of 1.1 KV grade of following sizes on wall surface/truss (or in recess of wall/floor by cutting the surface and making good the same) as required.(a) Up to 35 sq.mm (clamped with 1mm thick saddle)
7Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
8Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required(a) 4 x 35 sqmm (32 mm)
9(b) 4 x 25 sq mm (28 mm)
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required(a) 5/6 A switch
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required(b) 3 pin 5/6 A socket outlet
12Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
13Supplying and fixing following size PVC surface modular box with suitable modular plate and cover in front on wall surface along with providing connections with in the existing conduit and wiring as required.(a) 12 Module
14Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(a) 5/6 A switch
15Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(b) 3 pin 5/6 A socket outlet
16Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
17Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
18Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral
19(b) Triple pole and neutral
20Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(a) 8 way (4 + 24), Double door
21Supplying and fixing 63 A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Triple pole and neutral
22Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 100 A
23LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Streetlight LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(a) 90 watt
24LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 200 watt
25(b) 70 Watt
26Supplying, fixing, testing and commissioning of 1200 mm 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy of 100 lumens/W by replacing damaged spares of the existing fitting etc . as required (ISI certified)
27Supplying, Installation, Erection Testing and commissioning of 5 HP, 50 Hz, 415V, 1500 RPM(or above) three phase bore well submersible pump (ISI certified) of suitable head range ( 80 - 250 metres) and discharge ( 90 - 15 Lpm ) with delivery dimensions of 38 mm made of oil sealed SS body including providing connections with sumbersible flat cable and pipes for functioning of motor as required at the site of work. (Note: The installation shall include hanging the motor along with existing PP Rope and Submersible cable required for functioning of motor in complete)
28Supplying, Installation, Testing, Commissioning of 5 HP Three Phase DOL starter with suitable contactor and relay (SPPR) inside suitable SMC Box of dimensions 450 x 375 x 200 mm by fixing the SMC box on existing angle iron setup including making connections of incoming and out going cables etc as required.
29Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with foot valves, unions and other accessories with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External Worka) 40 mm(1.5 inch) nominal dia Pipes
30Supplying, Installation, Erection Testing and commissioning of 2 HP, 50 Hz, 210V, 1500 RPM(or above) single phase open well submersible pump (ISI certified) of suitable head range and discharge with delivery dimensions of 50 mm including providing connections with sumbersible flat cable and pipes for functioning of motor as required at the site of work. (Note: The installation shall include hanging the motor along with existing PP Rope and Submersible cable required for functioning of motor in complete)
31Supplying, Installation, Testing, Commissioning of 2 HP Single Phase DOL starter with suitable contactor and relay (SPPR) inside suitable SMC Box of dimensions 370 x 270 x 210 mm by fixing the SMC box on new angle iron setup (erected in concrete) including making connections of incoming and out going cables etc as required.
32Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with foot valves, unions and other accessories with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External Worka) 50 mm nominal dia Pipes
33Supplying of 25mm dia twisted polypropylene rope(industrial grade) for hanging the motor pump inside the exisitng well as required. (ISI certified).
34Supplying of 3 core flat 4 sqmm PVC insulated copper conductor cable (for submersible use) of 1.1 KV grade conforming to IS694:1990 with up to date amendments.
35Supplying, installation, testing & commissioning of 40 W post top gate light landscape luminiare with IP 65 protection, glare-free and uniform light distribution with die cast housing and PC diffuser & spun aluminum reflector with lumen efficacy of >100 lm/W, colour temp 5700 K, THD < 10%, PF ≥ 0.95 with in built 10 kV surge arrestor on existing pole / gate post with suitable accesories including providing connections etc at site of required at the site of work.
36Supplying and fixing hot press molded SMC box of following size on new suitable angle iron setup (erected in cement concrete) with suitable clamps and fitting arrangements including terminating the incoming and outgoing cables as required at the site of work.(a) 700 x 480 x 210 mm (inside)
37Credit items to be taken out
38(a) Dismantled submersible motor
39(b) Dismantled DBs, Switch boards, GI pipes and clamps etc.
40(c) Dismatled Street light fittings
41(d) Dismantled open well motor
42(e) Dismantled aluminium UG cables Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56399645
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 8.12 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for annual repair maintenance Electrical Works At Fci Fsd Ramanathapuram For The Year 2026-27. Sh: Replcement Of Damaged Underground Cables And Submersible Pumpset Along With Allied Works
Basic Detail
Tender No 2.1/2026-27 FSD Ramanathapuram
Bidding Type Tender
Location
City Ramanathapuram
State Tamil Nadu
Key Dates
Publish Date 10 Jul 2026
Submission Date 20 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 8.12 Lakhs
Tender Fee Ref. Documents
EMD 16260
Exemption Not Available
Document List
2a3c316c-f138-4d10-b842-5533ed49e0da.html
BOQ_963484.xls
PB.pdf
TB.pdf
Tendernotice_1 (5).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

2a3c316c-f138-4d10-b842-5533ed49e0da.html

xls

BOQ_963484.xls

pdf

PB.pdf

pdf

TB.pdf

pdf

Tendernotice_1 (5).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders