Tender For Extension Of Existing Tahsil Office Building And Refurbishment Of Tahsil Office Building At Mouda And K Tee, Dist Nagpur.
Tender Value
28.57 Crore
Estimated cost
Bid Submission
24 Jul 2026
8 days left
EMD
28.57 Lakhs
Bank guarantee accepted
Document Fee
35400
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Extension Of Existing Tahsil Office Building And Refurbishment Of Tahsil Office Building At Mouda And K Tee, Dist Nagpur.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work Portion (Part A) |
| 2 | Dismantling brick masonry in lime or cement mortar and stacking the materils asdirected with all leads, lifts etc.Ground Floor |
| 3 | First Floor |
| 4 | Removing rich mix cement concrete including stacking the spoils as directed with allleads, lifts etc, complete.Ground Floor |
| 5 | First Floor |
| 6 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.First Floor |
| 7 | Removing doors and windows with frames and stacking the materials as directedwith all leads, lifts etc. complete.Ground Floor |
| 8 | First Floor |
| 9 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete.Ground Floor |
| 10 | First Floor |
| 11 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeGround Floor |
| 12 | First Floor |
| 13 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwingout the refusal outside etc. complete.Ground Floor |
| 14 | First Floor |
| 15 | Providing and grouting the holes by Poly Ceramic Cementitious i.e NicGrout G 06 + 53 grade cement material of as per requirement to reduce the porosity of concrete / Masonry structure and to increase the strength of structure using grouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge.Ground Floor |
| 16 | First Floor |
| 17 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete.Ground Floor |
| 18 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.Ground Floor |
| 19 | First Floor |
| 20 | Second Floor |
| 21 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -8mm dia 160mm depthFirst Floor |
| 22 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depthFirst Floor |
| 23 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -12 mm dia 240mm depthFirst Floor |
| 24 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -16 mm dia 320mm depthFirst Floor |
| 25 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -20 mm dia400mm depthFirst Floor |
| 26 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -25mm dia 500mm depthFirst Floor |
| 27 | Providing and carrying out core cutting in RCC beam / slab at plinth level or at any floor level, without damaging the reinforcement, using a diamond core cutting machine, for holes of 150 mm diameter and 300 mm depth, including marking, drilling, carefully removing the core, and disposing of debris, complete in all respects as directed by the Engineer-in-Charge.Ground Floor |
| 28 | First Floor |
| 29 | Providing and carrying out core cutting in RCC beam / slab at plinth level or at any floor level, without damaging the reinforcement, using a diamond core cutting machine, for holes of 100 mm diameter and 300 mm depth, including marking, drilling, carefully removing the core, and disposing of debris, complete in all respects as directed by the Engineer-in-Charge.Ground Floor |
| 30 | First Floor |
| 31 | Providing and carrying out core cutting in RCC beam / slab at plinth level or at any floor level, without damaging the reinforcement, using a diamond core cutting machine, for holes of 100 mm diameter and 150 mm depth, including marking, drilling, carefully removing the core, and disposing of debris, complete in all respects as directed by the Engineer-in-Charge.Ground Floor |
| 32 | First Floor |
| 33 | Providing and carrying out core cutting in RCC beam / slab at plinth level or at any floor level, without damaging the reinforcement, using a diamond core cutting machine, for holes of 150 mm diameter and 150 mm depth, including marking, drilling, carefully removing the core, and disposing of debris, complete in all respects as directed by the Engineer-in-Charge.Ground Floor |
| 34 | First Floor |
| 35 | Providing and carrying out Wall Saw (controlled Demolition) Fast, Flexible and Precise method of Cutting reinforced concrete for dimensions limited to 73cms. Cutting concrete with Hilti Wall saw DS TS20-E 1.6 3x400V electrical/DS TS32 LP32 3x400V Hydraulic Unit/Wall saw DSTS 20-CA electric wall saw. Wall sawing is a nonexplosive, non-destructive form of controlled demolition that leaves remaining structures safely intact. Blade to be used is Hilti Wall saw blade DS-BT 600-1600/HI C-H ensure safety. Ensuring the entire system to be Dust Free, Noise Free and Vibration Free. including marking, drilling, carefully removing the cutting, and disposing of debris, complete in all respects as directed by the Engineer-in-Charge.Ground Floor |
| 36 | First Floor |
| 37 | Providing and carrying out Wire Saw (controlled Demolition) Fast, Flexible and Precise method of Cutting reinforced concrete for dimensions more than 73cms where surgical accuracy for retrofitting, reengineering and reconstruction projects. Cutting concrete with Hilti Wire saw DS WS15 3x400V Electric/Wire saw DS WSS30 (3x400v) Hydraulic System. Wire sawing is a non-explosive, non-destructive form of controlled demolition that leaves remaining structures safely intact. Plus, our wire sawing can cut sections of concrete and metal to virtually any size and volume, they're capable of cutting complex and irregular shapes, and they always leave a smooth finished surface with no over cutting at the corners. Reduced risk of Wire breakage and ensure safety due to pneumatic/Hydraulic feed. Use only sawing wires that comply with the requirements of ISO/IEC 13236 with Connector DS-WC to ensure safety while in operation., including marking, drilling, carefully removing the cutting, and disposing of debris, complete in all respects as directed by the Engineer-in-Charge.Ground Floor |
| 38 | First Floor |
| 39 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansGround Floor |
| 40 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical MeansGround Floor |
| 41 | Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Up to 4KmGround Floor |
| 42 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper.Ground Floor |
| 43 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.Ground Floor |
| 44 | Providing antitermite treatment to the sides of flooring of the existing building as per I.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percent of chlorodane emulsion concentrate at the rate of 50 ml per hole and sealing by filling putty etc. complete covering 2 years guarantee on bondpaper.Ground Floor |
| 45 | Providing antitermite treatment to the wooden frames of doors/windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper.Ground Floor |
| 46 | Providing antitermite treatment to the sides of flooring of the existing building as per I.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percent of chlorodane emulsion concentrate at the rate of 50 ml per hole and sealing by filling putty etc. complete covering 2 years guarantee on bondpaper.Ground Floor |
| 47 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.Ground Floor |
| 48 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade)Ground Floor |
| 49 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm.Layers including watering and compacting etc. complete.Ground Floor |
| 50 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering andcompaction etc. complete.Ground Floor |
| 51 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 52 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 53 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 54 | First Floor |
| 55 | Second Floor |
| 56 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Providing cast in situ / ready mix M25 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) withSCADAGround Floor |
| 60 | First Floor |
| 61 | Second Floor |
| 62 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Second Floor |
| 63 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 64 | First Floor |
| 65 | Second Floor |
| 66 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 67 | First Floor |
| 68 | Second Floor |
| 69 | Providing and laying Cast in situ/Ready Mix C.C. M-25 of trap metal for RCC rectangular grid beam with slab as per detailed design and drawing or as directed including dewatering if necessary, steel centering, formwork, cover blocks, laying/pumping, compacting, finishing the form surface with C.M. 1:3 of sufficient minimum thickness to give smooth and even surface or roughening them if special finish is to be provided and curing complete (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground Floor |
| 70 | Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook andpainting to exposed surfaceGround Floor |
| 71 | First Floor |
| 72 | Second Floor |
| 73 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Ground Floor |
| 74 | First Floor |
| 75 | Second Floor |
| 76 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Second Floor |
| 77 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/-Second Floor |
| 78 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.Second Floor |
| 79 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding testetc. complete.First Floor |
| 80 | Second Floor |
| 81 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.First Floor |
| 82 | Second Floor |
| 83 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Ground Floor |
| 84 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Ground Floor |
| 85 | First Floor |
| 86 | Second Floor |
| 87 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Ground Floor |
| 88 | First Floor |
| 89 | Second Floor |
| 90 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc.complete.Ground Floor |
| 91 | First Floor |
| 92 | Second Floor |
| 93 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffoldingand curing etc. complete.Ground Floor |
| 94 | First Floor |
| 95 | Second Floor |
| 96 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding andcuring etc. completeGround Floor |
| 97 | First Floor |
| 98 | Second Floor |
| 99 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.Ground Floor |
| 100 | First Floor |
| 101 | Second Floor |
| 102 | Providing Stampping polymer modified wall Plastering material to vertical surfaces, Wall plastering is premixed with Water and Bonding agents ( 2.5 kg mortor with ratio 1:5 mixed with 1kg polymer material) on the wall over Rough Plastered Wall in thickness of Approx. 10-12mm finalized with prescribed colour and stamping pattern as directed by Engineer Incharge. Providing and applying Acrylic polymer Sealer coat to the stamped area including removing Acid and Dust with water jet if required, after curing applying first coat of sealer using either spray pump, brush or roller @ 80 sqft per Ltr. After complete drying of first coat. Applying second coat @ 80 sq ft per Ltr , Allowing to dry for at least 4 hours etc. Including labour, fixing material, scaffolding etc. Job completeGround Floor |
| 103 | First Floor |
| 104 | Second Floor |
| 105 | Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete(Low VOC).Ground Floor |
| 106 | First Floor |
| 107 | Second Floor |
| 108 | Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (HeatReflective Paint).Ground Floor |
| 109 | First Floor |
| 110 | Second Floor |
| 111 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.Ground Floor |
| 112 | First Floor |
| 113 | Second Floor |
| 114 | Providing and fixing solid core flush door shutter in double leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.Ground Floor |
| 115 | First Floor |
| 116 | Second Floor |
| 117 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oilpainting 3 coats completeGround Floor |
| 118 | First Floor |
| 119 | Second Floor |
| 120 | Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the woodwork with oil painting 3 coats completeGround Floor |
| 121 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Ground Floor |
| 122 | First Floor |
| 123 | Second Floor |
| 124 | Ground Floor |
| 125 | First Floor |
| 126 | Second Floor |
| 127 | Twin Sash Casement Window frame of size 122 x 62 mm, sash 67 x 78 mm & bug-mesh sash of 42 x 84 mm. Providing and fixing factory made uPVC twin sash casement glazed window and door (White Colour) comprising of two shutters, one outward opening having glass and one inward opening having SS Mesh and integrated grill provision between two shutters. uPVC multi-chambered frame, sash, bugmesh sash and mullion (where ever required) extruded profiles with wall thickness of 2.3mm (+-0.2 mm) duly reinforced with G.I section 1.50 wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-Ground Floor |
| 128 | First Floor |
| 129 | Second Floor |
| 130 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.Ground Floor |
| 131 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size67 x 78 mm.Ground Floor |
| 132 | First Floor |
| 133 | Second Floor |
| 134 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm .Ground Floor |
| 135 | First Floor |
| 136 | Second Floor |
| 137 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. completeGround Floor |
| 138 | First Floor |
| 139 | Second Floor |
| 140 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.Ground Floor |
| 141 | First Floor |
| 142 | Second Floor |
| 143 | Providing of 120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\\"Non Combustible by Nature\\"). Lead lined to check radiation. Code No; 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODENDOOR - Fire Door Tested in accordance to IS: 3614 Part 2. a) Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets with 10mm overlap from either side & spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed in the groove of the Frame for fire and hot and cold smoke sealing, etc. complete as per direction of Engineer in ChargeGround Floor |
| 144 | First Floor |
| 145 | Second Floor |
| 146 | Providing of 120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\\"Non Combustible by Nature\\"). Lead lined to check radiation. Code No; 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODENDOOR - Fire Door Tested in accordance to IS: 3614 Part 2.b) Shutter: Providing of 57mm thick asbestos free composite, 'TUFWUD' brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 mm with 30mm thick infill of ceramic fibre (density 128 Kilograms/CMT) vermiculite mix, 3mm thick Lead Sheet on one side faced & 3mm Fire retardant High Density Fibreboard, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of Intumescent paint of minimum 300 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping.Ground Floor |
| 147 | First Floor |
| 148 | Second Floor |
| 149 | Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\\"Non Combustible by Nature\\"). with prior approval of concerned Superitending Engineer. c) Vision Panel:1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside theshutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11mm thick havingminimum 120 minutes fire DescriptionGround Floor |
| 150 | First Floor |
| 151 | Second Floor |
| 152 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing inC.M. 1:3 curing and cleaning etc. complete.Ground Floor |
| 153 | First Floor |
| 154 | Second Floor |
| 155 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.Ground Floor |
| 156 | First Floor |
| 157 | Second Floor |
| 158 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc.complete.Ground Floor |
| 159 | First Floor |
| 160 | Second Floor |
| 161 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.Ground Floor |
| 162 | First Floor |
| 163 | Second Floor |
| 164 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.completeGround Floor |
| 165 | First Floor |
| 166 | Second Floor |
| 167 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)Ground Floor |
| 168 | First Floor |
| 169 | Second Floor |
| 170 | Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polishGround Floor |
| 171 | First Floor |
| 172 | Second Floor |
| 173 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)Ground Floor |
| 174 | First Floor |
| 175 | Second Floor |
| 176 | Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing inS.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. completeGround Floor |
| 177 | First Floor |
| 178 | Second Floor |
| 179 | Providing and fixing 90 cm x 60 cm Marble plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade completeGround Floor |
| 180 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.Ground Floor |
| 181 | First Floor |
| 182 | Second Floor |
| 183 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.Ground Floor |
| 184 | First Floor |
| 185 | Second Floor |
| 186 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground Floor |
| 187 | First Floor |
| 188 | Second Floor |
| 189 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.Ground Floor |
| 190 | First Floor |
| 191 | Second Floor |
| 192 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.Ground Floor |
| 193 | First Floor |
| 194 | Second Floor |
| 195 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Ground Floor |
| 196 | First Floor |
| 197 | Second Floor |
| 198 | Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.Ground Floor |
| 199 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor |
| 200 | First Floor |
| 201 | Second Floor |
| 202 | Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor |
| 203 | First Floor |
| 204 | Second Floor |
| 205 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.Ground Floor |
| 206 | First Floor |
| 207 | Second Floor |
| 208 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.Ground Floor |
| 209 | First Floor |
| 210 | Second Floor |
| 211 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brandby Ex. Engr. is necessary before use)Ground Floor |
| 212 | First Floor |
| 213 | Second Floor |
| 214 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete.Ground Floor |
| 215 | First Floor |
| 216 | Second Floor |
| 217 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.Ground Floor |
| 218 | First Floor |
| 219 | Second Floor |
| 220 | Providing and fixing C.P. a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.Ground Floor |
| 221 | First Floor |
| 222 | Second Floor |
| 223 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. completeGround Floor |
| 224 | First Floor |
| 225 | Second Floor |
| 226 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Ground Floor |
| 227 | First Floor |
| 228 | Second Floor |
| 229 | Providing and fixing white wash basin with half pedestal of size 515mmX615mmX460mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipeconnection upto the outside face of the wall.Ground Floor |
| 230 | First Floor |
| 231 | Second Floor |
| 232 | Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with allnecessary pipe connection etc. complete.Ground Floor |
| 233 | First Floor |
| 234 | Second Floor |
| 235 | Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)Ground Floor |
| 236 | First Floor |
| 237 | Second Floor |
| 238 | Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate up to 4.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make withP.V.C. waste pipe with fitting arrangement etc.complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)Ground Floor |
| 239 | First Floor |
| 240 | Second Floor |
| 241 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for thegully trap.Ground Floor |
| 242 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.Ground Floor |
| 243 | Full Height Partitions in Glass finish - Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.Ground Floor |
| 244 | First Floor |
| 245 | Second Floor |
| 246 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete.Ground Floor |
| 247 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtightC. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.Ground Floor |
| 248 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.Ground Floor |
| 249 | Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.Ground Floor |
| 250 | Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacityabove 1000 to 20,000 litresSecond Floor |
| 251 | RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technicalspecification and direction of the Engineer in charge.Ground Floor |
| 252 | Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete.Ground Floor |
| 253 | First Floor |
| 254 | Second Floor |
| 255 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MMDIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.Ground Floor |
| 256 | First Floor |
| 257 | Second Floor |
| 258 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester.Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67%Water absorption (as per ASTM):-0.30% Flammability as per ASTMTensile strength:-115 MPASpecific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mmOutlet pipe size rigid PVC:-80mmGas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition)With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below i) Up to 200 user size (4mx2.0mx1.25m), Capacity of Biodigester:-10000 liters, Area of top, bottom and side walls: - 31.00 sq.m, Area of partition walls: 10.00sq.m, Total weight of FRP: - 462.60 Kilogram, Bacteria inoculums quantity: - 3400 liters, Minimum thickness of side walls / top and bottom: 7mm, One Number of inside partitions: - 4,Minimum thickness of partition wall: 4mmGround Floor |
| 259 | FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MMProviding & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm.SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‘C’ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C- channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mmGround Floor |
| 260 | First Floor |
| 261 | Second Floor |
| 262 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should betaped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Ground Floor |
| 263 | First Floor |
| 264 | Second Floor |
| 265 | Anutone Pixel Square 3/8, 600x600x12.5mm, Square edge (T15 Grid system) : Providing & Fixing of Anutone pixel Square 3/8, perforated gypsum panels,white vinyl laminated front, backlined with white acoustical fleece, having 3x3mm square perforations @ 8.33mm pitch - 10% open area, of size 600x600x12.5mm, square edge having base density 700Kgs/m3, weight 8kg/m2 which is suspended by using 0.3mm thick Anutone Skelet TrelisT15 metal grid system. Anutone Skelet TrelisT15 metal grid system of 600x600mm module includes Anutone Skelet WA15W30 wall angle with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Anutone Skelet MT15W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Anutone Skelet CT15W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally Anutone Skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600x600mm module. Anutone pixel Square 3/8, square edge of size 595x595x12.5mm shall be placed into the grid size of 600x600mm. Technical Parameters : • Fire (Class) – 1 & P • Acoustics – NRC 0.75 • Thermal conductivity (W/mk)– na • Climate (°C, RH) – 50, 90 • Light reflectance (%) – 80 • Green (VOC, RC %) – Low, 25 Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.Ground Floor |
| 266 | First Floor |
| 267 | Second Floor |
| 268 | Providing & Fixing of acoustic wall panelling Consisting Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x1200x15mm having density 400Kgs/m3, weinglii4120ki/m2 installed by using GI strut system The GI strut work includes Cross channel having thickness 0.45mm, lenght 3600mm,knurled web50, depth 50mm and equal flanges of 13mm is fastened to Wall positioned horizontally in regular manner at 600mm centers. PVC Vinyl core UV treated HSpline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers,Kerfed edge Fabric wrapped panels shall be then inserted into the H- spline against wall to perfact fit. Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.Ground Floor |
| 269 | First Floor |
| 270 | Second Floor |
| 271 | Providing & Fixing of 300C wooden finish Perf + NWT (0.7 NRC) 2.0 mm diameter 5mm c/c pasted with aproved color NWT corrosion resistant Alluminium Magnesium Alloy metal ceiling Hunter Douglas consisting of panel 300m wide x 30 mm deep x 0.7 mm thick with bevel edge having panel length upto 6 mtrs. coil coated on a continuous paintlien, Double baked and roll formed for higher straight and good roll forming characteristics with 21% perforation. The panel ends are raised upto 29 mm . The panel about each other with a narrow V groove. Panel shall be clipped to a backed enamelled aluminium panel carrier of 41.5 mm wide x 62 mm deep x 0.95 mm thick in standard length of 5 mtrs. made of double baked enamelled aluminium a mgnesium alloy AA3005 black with cut outs to hold panels module of 300 mm and at distance of 2.4 mtrs. the carrier shall be suspended by means of GI suspension rod 4mm diameter and suspension clip at 1.3 mtr.distancePaint finish:Alluminium panels shall be chromatised for maximum bond between metal and paint,enamelled twice under hgih temperatuve one side with full primer and Luxacote finish,the other side (Inner side) with a primer coat and skin coat on a Continous paint line. Seismic Zone V compliance - Metal facade should be Tested for Seismic Zone V compliance as per IS 1893 part 1-2016”Mode of measurement : Measurements shall be wall to wall without deductions for lights, diffusers, columns etc. Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.Ground Floor |
| 272 | First Floor |
| 273 | Second Floor |
| 274 | Providing & fixing of Airflex Smash approved Wooden flooring system that should be compliance with the Area elastic with total thickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and l0mm Power Rubber Pad. Product top finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat and saliva resistance according to DII 53160-1/2) to have higher polish life. The wooden flooring should have Eco-friendly manufacturing process with 100% sustainable and manageable plantation resource with raw material. The product should have been produced through K ilned and dried technology to maintain suitable moisture content. The top wood should necessarily be sourced from 100% sustainable resource and should have with prefinished including sanding & polishing. Structure of system should be l0mm thick rubber pad, 45 mm thick p ine runner with the width of 70mm, followed by the 20mm top flooring. Top wood plank sizes should be 20mm Thick, 130 mm Wide and 1830mm length. Runners to be placed at a distance of 305mm C/C. EntireApproved make : Ebaco, Airflex, NLF & orbit.Second Floor |
| 275 | Providing and fixing of Hunter Douglas manual roller blinds with Blackout or Sunscreen fsbric 5% or 10%. Control clutch drive unit engineered heavy duty chain drive pulley operating system consisting of gear clutch housing and locking plug containing 6 ribs and flexible to be inserted in 37mm or 50mm Roller tube. It is self lubricating exclusive clutch with safety pins for secure bracket installation and unlocking pin for quick manual removal. Universal clutch is most convenient for large windows down to the smallest windows. It shall be driven by a ball chain pulley with plastic ball chain and can be universally positioned either Right hand or Left hand side of the shade. Clutch gear ratio 1.75:1for reduced operating force on larger blinds. Tube bearing plug Idler: Exclusive self lubricating spring loaded plastic bearing end plug with positive locking wheel allows for adjustment and provides for a secure installation and removal of shade. Tube bearing plug contains 6 ribs and flexible to be inserted in 37mm or 50mm roller tube. Mounting Hardware Brackets: Universal brackets including end plug bracket with lock down retainer device. Brackets finish of powder coated Aluminium installation brackets made of stamped and hardened steel with 46mm projection for wall, ceiling and side fitting with screws and end cap covers. Valance Systems: Flat extruded valance alloy 6060 and temper T66 EN755 size of 5.6mm * 84.5mm and wall thickness 1.6mm with standard powder coat white finish. Valance systems protect and hide the front of the fabric on the tube, creating a more sleek look. Roller Tube: Circular-shaped aluminium tube extruded from alloy 6060 and temper T66 – EN755 of 37mm inside diameter and outside diameter 40.2mm extruded tube to have a 1.6mm wall thickness with standard anodized natural finish. Heavily reinforced with minimum six internal ribs providing additional deflection strength and allows for secure placements of clutch and end plug. Bottom Rail: Flat-shaped extruded aluminium from alloy 6060 and temper T66 – EN755 of dimension 13mm * 30mm and wall thickness of 1.5mm and weight more than 350g/m providing additional stability to avoid swaging and damage of shade fabric. Rail standard finish of powder coat white colour and provided end cover. Ball Chain: Shall be 2mm diameter cord with 4.5mm diameter acetal balls moulded coaxially to it on 11.8mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades. Plastic parts: All plastic components are UV-stable compounds available white colour . Screen Fabric having Following Specification Composition: 24%PES+76%PVC Openness factor: Approx 5% Thickness: 0.56±5% mm Weight per ㎡ :445 ±5% g/m2Weave: Basket Weave 2 x 1 Fire resistance: NFPA 701 Color fastness: AATCC16 Grade 4-5 Health/Safety certificate: Oekotex /GreenGuard Blackout fabric having following specifications: Composition- 100% fiberglass with PVC coated or equivalent. washable Openness factor- opaque Weight (gram/ sqm)- min 407 g/sqm Thickness- min 0.51 mm Fire Classification- NFPA-701 or equivalent Fastness to light- 6-7/8 or higher Indoor Air Quality- GreenGuard / Eco-Codice Certified.Approved make :Hunter Douglas, Anutone, NLF, AMI & orbit.Ground Floor |
| 276 | First Floor |
| 277 | Second Floor |
| 278 | Luxalon® Lay-in Alu Plain Tile Ceiling System: Providing & fixing of Luxalon® Lay-in Tile Plain False Ceiling on 24mm ‘T’ Framework of module 600mm x 600mm. Panels shall be manufactured by Hunter Douglas of size 575mm x 575mm made out of 0.4mm thick Galvanised Steel. When the tiles are perforated it shall be 2.5mm dia 5.5mmc/c. Tiles to be stove enamelled on a continuous application for pre-treatment. The coils to go through 4 stages of pre-treatment, three times oven baked through conversion coating, priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability. The coils to be painted on both sides after degreasing. Inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and topcoat of approved colour of 15 microns. The Tile will be manufactured on advanced equipment, which includes several levelling. The tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. Grid system for fixing ceiling tiles shall comprise of Tees. The 24mm main tee runners shall be suspended at an interval of 1200mm centre to centre. The 24mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 24mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. The main tee shall be supported by means of 4mm G.I. rod from slab/roof. The suspension shall be provided at 1200 to 1500mm centre to centre. Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Approved Make :Hunter Douglas, Anutone, NLF, & Elegence.Ground Floor |
| 279 | First Floor |
| 280 | Second Floor |
| 281 | Designing, Providing, erecting and fixing structural glazing semi-unitized using specially designed aluminum grade 63400 WP IS: 733 and ID: 1285 electro colour anodized 25 micron or pure polyester powder coated 65 microns in approved shade and colour through adequately designed MS galvanized / aluminum anchor brackets. This includes structural grade and weathering grade silicon sealant ''Dow Corning'' or ''GE Silicon'' or equivalent as per the design requirement. This includes structural designing, shop drawing complete. The structure glazing shall be double glazed 23mm thick (6mm thick one way reflective on outer side, 12 mm air gap and 5 mm thick clear toughened glass on inner side). No members to visible from outside complete as per drawing and direction of engineer in charge. Including required aluminum sub-frame Silicon filling all height i/c double height for straight.Ground Floor |
| 282 | First Floor |
| 283 | Second Floor |
| 284 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre)Ground Floor |
| 285 | First Floor |
| 286 | Second Floor |
| 287 | Providing and fixing Elegance® U Baffle GI panel Facade manufactured by M/s Elegance Metal Ceiling of approved colour consisting of panel size 50 mm width X 100 mm deep using 0.5 mm thick, panel length upto 3 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance for higher strength and good roll forming characteristics. Panels shall be clipped to a G.I slotted angle 2 mm thick, Black Colour coated, one leg of the carriers with cut outs to hold the panels in a module of 100 mm. Panel carrier shall be fixed by means of wall Channel at a distance of 1.8 mtr c/c. (Actual distance of Channel /carrier to be calculated based on the actual drawing)PAINT FINISH: GI panels shall be chromatized for maximum bond between metal and paint enamelled twice under high temperature, Exposed side with a full primer and finish coat on a Continuous Paint Line.CEILING FINISH ABOVE U BAFFLE Facade : Facade area above U Baffle to be painted in black colour before fixing this system (Not in the scope of Elegance) MODE OF MEASUREMENTS: Measurements shall be wall to wall without any deductions for lights, diffuses, columns etc. Approved Make : Anutone, Elegance, Luxalon , AnutechGround Floor |
| 288 | First Floor |
| 289 | Second Floor |
| 290 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed. |
| 291 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - IMaterial |
| 292 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate) |
| 293 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) |
| 294 | Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1:8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary ) |
| 295 | Painting Line, Dashes, Arrows etc on Roads in two coats on new work with ready mixed road marking paint confirming to I.S. 164 on Bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control (Over/Upto cm wide) (MORTH-803) -- SurfaceOver 10cm Wide On New Surface |
| 296 | Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.2mm aluminum sheet Class B |
| 297 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 298 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench complete. |
| 299 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 300 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 301 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) |
| 302 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coatsof approved shade Weight of gate 35 Kilogram/Smt. |
| 303 | Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete. |
| 304 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete. |
| 305 | Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) withSCADA |
| 306 | Providing and laying in situ / ready mix M-20 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications ( VSI sand finely washed etc )i) Height up to 5 m, normal rate.ii) Height 5 to 7.50 m, add 5 percent extra over basic rate.iii) Height 7.50 to 10 m, 7.50 percent extra.iv) Over 10 m Height, add 10 percent extra for every 2.50m rise. |
| 307 | Providing and fixing bituminous pad 25mm thick for expansion joints in retaining wall, compound wall etc. complete. |
| 308 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a) |
| 309 | Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b) |
| 310 | Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.14, item no 2) |
| 311 | Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7'' x 8\\"(plants list) 1(a) serial no 15. |
| 312 | Providing on site required variety of HedgesWell Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8'' x 10\\"(plants list) 7(b) serial no 10. |
| 313 | Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs.for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5) |
| 314 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilledlabour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) |
| 315 | Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 daysOnly (As per P&G DSR 2022-23 Items of garden work,Sr No.29) |
| 316 | Maintainance of Newly Developed ShrubsArea. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31) |
| 317 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45a) |
| 318 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of soil 0.079 cum x 800/cum = 63.20/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.43a) |
| 319 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b) |
| 320 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.45 x 0.45 x 0.45m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 21.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b) |
| 321 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and diseases Name:-ALLAMANDA ;Bag Size 10 x10'', ht 15- 30CM (plants list sr no1 ( b) , item no 2 Page no -16) |
| 322 | Providing on site Flowering Climbers and creepers Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Allamanda (allamanda cathertica) ;Bag Size 7 x 8'', ht 15- 30 CM (plants list sr no 3 , item no 2 Page no -19) |
| 323 | Providing on siteBalbous / Rhizomatous plants Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Lilium sp. ;Bag Size 7 x 8'', ht 30- 45 CM (plants list sr no 4 , item no 6 Page no -20) |
| 324 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bahva (Amaltash);Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 1 Page no -22) |
| 325 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Arjuna ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 3 Page no -24) |
| 326 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 4 Page no -24) |
| 327 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 5 Page no -24) |
| 328 | Providing on site HEDGES Specification:- Well developed, healthy Foliage/ Half bloom stage, free from pest and diseases .Name:-Bougavillae Thema ;Bag Size 18 x18'', ht 60cm to 75 cm (plants list sr no 7d, item no 2 Page no -26) |
| 329 | Providing on site HEDGES Specification:- Well developed, healthy Foliage/ Half bloom stage, free from pest and diseases .Name:-Bougavillae Glabra;Bag Size 13 x13'', ht 60cm to 75 cm (plants list sr no 7d, item no 3 Page no -26) |
| 330 | Providing on site Ground Cover Specification:- Well developed, healthy, free from pest and diseases .Name:-Asparagus ;Bag Size 7 x8'', ht 10cm to 20 cm (plants list sr no 8, item no 3 Page no -26) |
| 331 | Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Areca Palm ;Bag Size 18 x18'', ht 8- 10'(plants list sr no1,item no 11d) |
| 332 | Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Fox tail palm;Bag Size 18 x18'', ht 8- 10'(plants list sr no3,item no 11d) |
| 333 | Providing and Supplying Cement Pot size 36 Inch x 18 inch x 18 Inch of good quality, Durable well finish on edge with good strength |
| 334 | Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) inearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12) |
| 335 | Excavation pit size 0.45 x 0.45 x 0.45 m for plantingearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.10) |
| 336 | Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.22) |
| 337 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27) |
| 338 | Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35) |
| 339 | Electrical work (Part A) |
| 340 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 341 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 342 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 343 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 344 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 345 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 346 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 347 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 348 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 349 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 350 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 351 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 352 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 353 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 354 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 355 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 356 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 357 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 358 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 359 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 360 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 361 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 362 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 363 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW |
| 364 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW |
| 365 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 366 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 367 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 368 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 369 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 370 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 371 | Supplying and installing 3 m fibre patch cord duplex single mode for OS1/OS2 complete. |
| 372 | Supplying and installing single mode simplex pigtail with SC/LC splicing complete. |
| 373 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 374 | Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 375 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 376 | Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU |
| 377 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 378 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 379 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 380 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 381 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 382 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 383 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 384 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 385 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 386 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 387 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Without Remote) |
| 388 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 389 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 390 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC |
| 391 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 392 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position asper specification no. APAC/ WAC |
| 393 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 394 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. |
| 395 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. |
| 396 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. |
| 397 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. |
| 398 | Supplying & erecting four pole ON LOAD change over switch, 415V, 160A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 399 | Supplying and erecting switch disconnector fuse (SDF) 415V, 25/32A, with enclosure, triple pole and neutral link AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch , insulation voltage 1000 V, with rotary handle for ON / OFF operation (without HRC fuse) |
| 400 | Supplying and erecting switch disconnector fuse (SDF) 415V, 160A, with enclosure, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V , with rotary handle for ON / OFF operation(without HRC fuse) |
| 401 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 402 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 403 | Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 404 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 405 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 406 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 407 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 408 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 409 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 410 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 411 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 412 | Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 413 | Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO |
| 414 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) |
| 415 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB. |
| 416 | Supplying & erecting HRC fuse cartridge 415V, 32A |
| 417 | Supplying & erecting HRC fuse cartridge 415V, 200A |
| 418 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 419 | Supplying and erecting acrylic sheet 2 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete. |
| 420 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 |
| 421 | Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 |
| 422 | Supplying and erecting GI sheet of 1.25mm (18 SWG) size 200 x 150 mm duly painted with red oxide & enamel paint for displaying the department, date of erection of the electrical installation with approved shade complete. |
| 423 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 424 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard |
| 425 | Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness) , with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB |
| 426 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 427 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 428 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 429 | Providing & erecting hot dipped galvanised ladder type cable tray /(Perforated type Cable tray) manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. |
| 430 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 431 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 432 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 433 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 434 | Providing and back filling ground enhancing compound 25 kg bag complete. |
| 435 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 436 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV |
| 437 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 438 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 439 | Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 440 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 441 | i) Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable forii) suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.iii) 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECPiv) A]2)For main electric motor driven fire hydrant system pump of 37kW capacity & relevant capacity jockey pump add Rs26217/-B]3) For main electric motor driven fire sprinkler system pump of 37kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs 161675/-C]3)For standby main electric driven fire hydrant/sprinkler system pump of 37kW capacity, add Rs 33616/-v) D]For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs 68318/-vi) E]1) for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs 17994vii) Total of FPC + A2+B3+C3 + D + E = 182320+26217+161675+33616+68318+17994 Adding 5%= 514713.15/- |
| 442 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 443 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 444 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 445 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 446 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 447 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 448 | Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 449 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 450 | Supplying and erecting 100 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 451 | Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 452 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 453 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 454 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL (2x8 points = 16) |
| 455 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ |
| 456 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC |
| 457 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 458 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 459 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 460 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 461 | Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD |
| 462 | Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 463 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR |
| 464 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 465 | Supplying, installing, testing and commissioning of 4 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP (For 2 Zone = 17839 Adding 25% for Each Zone i.e.50% for additional 2 Zones, 17839+8919.50=26758.50) (For Ground & First Floor) |
| 466 | Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR |
| 467 | Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC |
| 468 | Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC |
| 469 | Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC |
| 470 | Supplying, erecting, testing and commissioning of 0.5 sq. mm speaker wire complete. |
| 471 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. |
| 472 | Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 473 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 474 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall |
| 475 | Supplying and erecting of fire Exit & Fire Exinguisher signage Indicating the floor-number in words & system(Fire Extinguisher & Accessories ) |
| 476 | Providing and Erecting of Pre-Engineered Nut-Bolted Metal Water Tank of App x 24 to 25 Kilo Liters (24000 to 25000 Liters) of water storage capacity for fire fighting and other utility purpose. Tank having Diameter of 2.77 meter and height of 4.0 meter. Made with TATABLUESCOPE® ZINCALUME® G300, With Class AZ 150 Coating of Zinc & Aluminium. Factory Coated Steel Conforming IS 15961-2012. With Wall thickness of 0.6mm to 0.8mm, wall having corrugated structure having corrugation of 18mm depth and 75mm space. Including Liner made up of P.E.S base fabric of High Tenacity Polyester filament yarn of Sioen make of 850 GSM and water proofness of 200psi, suitable for drinking water and anti-algae properties. The fabrication of the liner which is holding the water shall be welded using Sealmless welding technology of High Frequency (HF) or Radio Frequency (RF) welding which is a technique used to join thermoplastic materials. It employs radio waves and pressure to create strong, high-quality welds. Operating at 27.12 MHz, this process uses electromagnetic energy to generate heat within the materials being joined. Top roof cover made with corrugated sheet. Having accessories Digital level indicator, over flow valve, inlet & outlet valves as per site requirement, internal rope ladder with aluminium steps, heavy duty commercial external ladder all HDG nut-bolts, anchor, fasteners, etc. Including transportation and installation within Maharashtra state. Service centre and manufacturing facility should be located in Maharashtra state for rapid repairs and service. Excluding Supporting structure and civil work for ground or roof mounted. |
| 477 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 478 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 479 | Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 480 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 481 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI(Detector Panel, DDPump, JokeyPump) |
| 482 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 483 | Supplying and erecting 12V/7.5Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 484 | ROYALTY & TESTINGRoyalty Charges on Mining materials used in construction. Sand |
| 485 | Royalty Charges on Mining materials used in construction. Murum & Soling Metal |
| 486 | Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Sieve Analysis |
| 487 | Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. ii) Liqiud limit & plastic limit |
| 488 | Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. ii) Compaction Test( proctor Density ) |
| 489 | Carrying out test of concrete casted at site in the form of cubes of 150x150x150mm size casted during conctering in the laboratory including conveying the cubes/material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Compessive strength |
| 490 | Carrying out Mix design with all Tests on Concrete Mix Design basic materials of concrete of various grade from the material collected at site in the laboratory including conveying all required material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. |
| 491 | Carrying out Basic test of Cement Standard Consistency,Fineness, Specific gravity, setting time (initial & Final)Compressive Strength,soudness in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. |
| 492 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Crushing value, ii) Impact value, iii) Specific gravity, iv) Water absorption |
| 493 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. v) Sieve lanalysis |
| 494 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vii) Abrasion Value |
| 495 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vi) Flakiness Index & Elongation Index. |
| 496 | Fineness Modulus (sieve Analysi) Silt & Clay Content |
| 497 | Chloride & Sulphate Content |
| 498 | Silt Factor |
| 499 | Testing of Steel Upto 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) |
| 500 | Carrying out various test of HYSD / TMT /FE-500 Steel transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Weight / metre, ii) Ultimate tensile stess, iii) Yield stress, iv) Elongation Test,a) Above 16mm dia. |
| 501 | Testing of Bricks for- Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). |
| 502 | Density Test,Compressive Strength , Water Absorption |
| 503 | Testing of Wood for Density and Moisture Content |
| 504 | Testing of Flush door for Knife Test, Adhesion Test, End Immersion Test. |
| 505 | Testing of Aluminium Section , thickness, mass per running meter |
| 506 | PVC Pipe75 |
| 507 | PVC Pipe 110 |
| 508 | GSB Mix design |
| 509 | Carrying out Standard test of water Absorption , Flexural test on Flooring Tiles (Ceramic tiles/Vetrified tiles etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.(i) Water Absorption (Set of 6 Tiles, Flextural test (Set of 6 tiles) |
| 510 | Carrying out Standard test of specific gravity on Flooring Stones (Kota Stone/graite Stones Stones etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete |
| 511 | Carrying out test of PH Value, Sulphate & Chloride Content on Water in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. |
| 512 | Paving Block (Density , Compressive Strength,Water Aborsption) |
| 513 | Civil work (Part B) |
| 514 | Executive's Table @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawingGround Floor |
| 515 | First Floor |
| 516 | Second Floor |
| 517 | Pedestal Unit @ 420Lx450Dx650HTProviding & Fixing of PEDESTAL @ 420Lx450Dx650HT :- To be made out of Complete Membrane consist of three Drawers as per drawing.Ground Floor |
| 518 | First Floor |
| 519 | Second Floor |
| 520 | Credestal @ 1200Lx450Lx650HTProviding & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing.Ground Floor |
| 521 | First Floor |
| 522 | Second Floor |
| 523 | Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 DrawerPedestal in between ) as per drawing.Ground Floor |
| 524 | First Floor |
| 525 | Second Floor |
| 526 | Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 DrawerPedestal in between ) as per drawing.Ground Floor |
| 527 | First Floor |
| 528 | Second Floor |
| 529 | Medium Height Partition @ 1800/1200HTTILE BASED PARTITION SYSTEM:- Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides.Ground Floor |
| 530 | First Floor |
| 531 | Second Floor |
| 532 | Free Standing Table @ 1500Lx600Dx750HTProviding and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particleboard,Ground Floor |
| 533 | First Floor |
| 534 | Second Floor |
| 535 | Free Standing Table @ 1350Lx600Dx750HTProviding and fixing Table of Size 1350 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particleboard,Ground Floor |
| 536 | First Floor |
| 537 | Second Floor |
| 538 | Conference Table @ 3600Lx1400Dx750HTProviding & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.First Floor |
| 539 | Second Floor |
| 540 | Full Height Steel Storage @ 750Lx450Dx2100HTProviding and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.Ground Floor |
| 541 | First Floor |
| 542 | Second Floor |
| 543 | Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.Ground Floor |
| 544 | First Floor |
| 545 | Second Floor |
| 546 | Book Case with Glass Shutter @ 825Lx300Dx1650HTProviding & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing.Ground Floor |
| 547 | First Floor |
| 548 | Second Floor |
| 549 | Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Basewith Leatherite UpholsteryGround Floor |
| 550 | First Floor |
| 551 | Second Floor |
| 552 | Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORSGASLIFT FOR HEIGHT ADJUSTMENT.Ground Floor |
| 553 | First Floor |
| 554 | Second Floor |
| 555 | Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather UpholsteryGround Floor |
| 556 | First Floor |
| 557 | Second Floor |
| 558 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric UpholsteryGround Floor |
| 559 | First Floor |
| 560 | Second Floor |
| 561 | Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.Ground Floor |
| 562 | First Floor |
| 563 | Second Floor |
| 564 | Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmDProviding and fixing Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thickM.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thickC.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns).Ground Floor |
| 565 | First Floor |
| 566 | Second Floor |
| 567 | Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmDProviding and fixing Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thickM.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thickC.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns).Ground Floor |
| 568 | First Floor |
| 569 | Second Floor |
| 570 | Sofa Set 3+1+1Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length:182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five SeatGround Floor |
| 571 | First Floor |
| 572 | Second Floor |
| 573 | Tea Table 900mm X 750mm X 450mm for m.s. ante chamberProviding And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc.Ground Floor |
| 574 | First Floor |
| 575 | Second Floor |
| 576 | Directional signageDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\\" x 9\\" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge.Ground Floor |
| 577 | First Floor |
| 578 | Second Floor |
| 579 | Floor Directories Providing and fixing acrylic multilingual Braille (raised dots)ADA compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions by the engineer in charge.Ground Floor |
| 580 | First Floor |
| 581 | Second Floor |
| 582 | Providing and fixing Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specifiedlocations as per the directions of the engineer in chargeGround Floor |
| 583 | First Floor |
| 584 | Second Floor |
| 585 | Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brandas per the direction of engineer in chargeGround Floor |
| 586 | First Floor |
| 587 | Second Floor |
| 588 | Design, supply, fabrication and fixing of SS, non glare Signage board (2 ft. x 2 ft.- 1 One Number) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm) as per the installation procedure specified by the manufacturer and as per accessibility standards and up to the satisfaction of the engineer in charge.Ground Floor |
| 589 | First Floor |
| 590 | Second Floor |
| 591 | Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\\"x 9\\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.Ground Floor |
| 592 | First Floor |
| 593 | Second Floor |
| 594 | Providing and Fixing Accessible Wayfinding and navigation signage systems - Providing and fixing in location as diected by Engineer in Charge, accessible modular wayfinding and navigational signage system comprising of ADA and Harmonised Guidelines compliant sigange and wayfinding elements, in multilingual, tactile and braille format. Sigange systems to be designed for entire building / complex under considerationGround Floor |
| 595 | First Floor |
| 596 | Second Floor |
| 597 | Providing & Fixing Curvilinear W/S tecitus @ 1500/1500Lx600/600Dx750/1200 HT, Tile based Aluminum partition system of 1200mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look. Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY (WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having 2B + 1F PEDESTAL @ 400LX450DX670HT. : 2 Drawers & 1 Filling Drawer pedestal with leveller finish in 18 MM thk. Prelaminated partical Board Board 2MM PVC Edge band to all Exposed Area & Metal Drawer with Centralized Lock with handle.as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case. Ground Floor |
| 598 | First Floor |
| 599 | Second Floor |
| 600 | Modular Conference System MAX one seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case. CONFERENCE TABLE - 6950L x2400D x750HTGround Floor |
| 601 | First Floor |
| 602 | Providing and fixing of Anutone Subtex Hush acoustical panels, hardened square edge, FR grade Hush fabric (colour choice) wrapped on encapsulated Glassfibre core panels of size 600x1200x25mm or , volume density 100Kgs/m3, weight 2.5kg/m2 installed by using Anutone Strut Impale Clips. Anutone Strut Impale Clips are attached are attached directly to the wall/frame work with the points extending outward and such that the spikes are truly horizontal. The spikes are tipped with Stick S7 adhesive. Then the panels are positioned and pressed into place.Technical Parameters • Fire (Class) – 1 & P • Acoustics – NRC Upto 0.9 • Thermal conductivity (W/mk) – 0.07 • Climate (°C, RH) – 40,95 • Light (%) – Colour dependent • Green (VoC, RC%) – Low, 35 All complete as per detail drawing, as specified and as directed by Architect Inclusive of all material, labour, transport, leads, lifts & shifts etc. APPROVED MAKE : Hunter Douglas, Anutone, NLF AccousticGround Floor |
| 603 | First Floor |
| 604 | Second Floor |
| 605 | Providing and fixing of Anutone Slats - made out of pinewood fibreboards, perforated wooden grooved slats L8-2 - (2mm grooves @ 8mm centers) / L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centres) /L64-2 - (2mm grooves @ 64mm centers), backlined with acoustical fleece, tongue-groove edge for a seamless look, of lineal dimension size 128mm x 2440mm x 16mm thick having density 800Kg /m3, weight 10 Kgs/m2, installed by using wall Panelling system. The wall panelling system shall includes GI Wall channel(WC25) having thickness 0.45mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm to be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Main channels(MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at every 1200mm centers with Suspender angle (SA25) having thickness 0.45mm, length 3600mm, unequal flanges of 25 & 10mm. GI Cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web of 50mm, depth of 25mm and equal flanges of 9.5mm is fastened to the Main channel (MC45) in the direction perpendicular to the Main Channel(MC45) at every 600mm centers. Aluminium core cross channel (CC18) having 0.5mm thick, 15mm & 27mm width, height 18mm, flanges of 7mm and length 2500mm is then fixed to the Cross channel (CC25) with the help of metal fasteners in direction perpendicular to the cross Channel at every 400mm centers. Slats of size 128mm x 2430mm x 16mm thick in then fixed perpendicular to CC18 with suitable edge & centre brackets. • Core -Fibreboard• Acoustics – NRC up to 0.75• Climate (OC RH) – 50, 70• Light reflectance – 75%• Green (RC %) – 25• Hygiene (VoC, Clean room) – Low, Class 1• Strength, Load capacity (Kg) - Antisag, Ball-Impact . Approved Make : Hunter Douglas, Anutone, NLF AccousticGround Floor |
| 606 | First Floor |
| 607 | Second Floor |
| 608 | Providing, Fixing & Supplying SS metal brush finish signage engraving 1mm with all material, labour, fixing equipment , lead and lift etc. completed.Ground Floor |
| 609 | First Floor |
| 610 | Second Floor |
| 611 | Providing, Fixing acrylic channel letter front side acrylic side wall aluminum profile 4 inch depth, back side ACP pannle trey Ads 1:8 led/wiring power supply and engraving at side all material, labour, fixing equipment , lead , Scaffolding and lift etc. completed.Ground Floor |
| 612 | First Floor |
| 613 | Second Floor |
| 614 | Providing, Fixing acrylic channel letter front side acrylic side wall aluminum profile 4 inch depth, back side ACP pannle trey Ads 1:8 led/wiring power supply and engraving at side all material, labour, fixing equipment , lead , Scaffolding and lift etc. completed.Ground Floor |
| 615 | First Floor |
| 616 | Second Floor |
| 617 | Supply & Installation of Airflex Smash approved Wooden flooring system that should be compliance with the Area elastic with totalthickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and l0mm Power Rubber Pad. Producttop finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat andsaliva resistance according to DII 53160-1/2) to have higher polish life. The wooden flooring should have Eco-friendly manufacturingprocess with 100% sustainable and manageable plantation resource with raw material. The product should have been produced throughK ilned and dried technology to maintain suitable moisture content. The top wood should necessarily be sourced from 100% sustainableresource and should have with prefinished including sanding & polishing. Structure of system should be l0mm thick rubber pad, 45 mmthick p ine runner with the width of 70mm, followed by the 20mm top flooring. Top wood plank sizes should be 20mm Thick, 130 mmWide and 1830mm length. Runners to be placed at a distance of 305mm C/C. Entire system should follow norms with the EN14904(06/2006) and technical parameters for the product should have friction of 95 according to EN 13036-4, Shock absorption of 45%according to EN 14808, Vertical deformation should be 1.8mm according to EN 14809 and Vertical ball rebound should be 99% accordingto EN 12235.” Approved Make : Ebaco, Forbo, EuroflexSecond Floor |
| 618 | Providing and fixing of Wall to Wall Carpet Model - ByzantiumCarpet Construction should be - Scroll Loop Pile , Fibre Compostion of carpet - 100% Solution Dyed PP , Tuft Gauge should be - 1/12′′ ,Tuft Density of carpet - 212850/SQM , Primary Backing - Woven , Pile Height - 4 MM , Total Height - 6 MM , Pile Weight - 750 GSM , TotalWeight of carpet should be - 1750 GSM , Secondary Backing - Blue Felt ,Approved Makes - Shanhua/Mohakw/ByzantiumGround Floor |
| 619 | First Floor |
| 620 | Second Floor |
| 621 | Providing, Fixing Green Wall of size 1m x 1m all material, labour, fixing equipment , lead , Scaffolding and lift etc. completed.Ground Floor |
| 622 | First Floor |
| 623 | Second Floor |
| 624 | Providing, Fixing Charcoal Sheet of size 8 feet x 2feet with 5mm thickness all material, labour, fixing equipment , lead , Scaffolding and lift etc. completed.Ground Floor |
| 625 | First Floor |
| 626 | Second Floor |
| 627 | Providing, Fixing Charcoal Louver of size 5 inch x 8 feet with 12mm thickness all material, labour, fixing equipment , lead , Scaffolding and lift etc. completed.Ground Floor |
| 628 | First Floor |
| 629 | Second Floor |
| 630 | Providing, fixing and installation of FRP Mural Work for various design. The FRP material layer thickness is 50mm to 75mm with waterproofing paint. The structure make by M.S. plate or angle as per drawing approved by Engineer-in-charge/ Architect and including all material, labour,lead, lift, transportation, fixing accessories and as per Engineer Incharge. etc. complete. Ground Floor |
| 631 | First Floor |
| 632 | Second Floor |
| 633 | Providing,Fixing of Art work made in Polyster Resin Gel Coat Chemical, casting & Molding with minimum 5mm thickness, along MS reinforcement with complete finished with required Primer & Dico colour as per the aesthetic of approved desgin & sizes 2'-0\\" x 3'-0\\" Ht and as per Engineer Incharge.Ground Floor |
| 634 | First Floor |
| 635 | Second Floor |
| 636 | Providing,Fixing of Art work made in Polyster Resin Gel Coat Chemical, casting & Molding with minimum 5mm thickness, along MS reinforcement with complete finished with required Primer & Dico colour as per the aesthetic of approved desgin & sizes 2'-6\\" x 5'-0\\" Ht and as per Engineer Incharge.Ground Floor |
| 637 | Providing & Fixing of Customize Acrylic Art Works for Words along with MS Stand of required sizes 750mm height on plate , Back lite & Acrylic Name as per design & Specification as per Engineer Incharge Second Floor |
| 638 | Providing and placing ( 90 cm x 60 cm)posters/portrait/painting of local and other artist to match the interior and surrouding locality including fixing and placing in position etc complete.Colour and designe approved by Engineering in charge etc complete.Specification as Directed by Engineer-in-charge etc,complete. P\P ( 90 cm x 60 cm)posters/portrait/paintingGround Floor |
| 639 | First Floor |
| 640 | Second Floor |
| 641 | Providing and placing ( 45 cm x 30cm)posters/portrait/painting of local and other artist to match the interior and surrouding locality including fixing and placing in position etc complete.Colour and designe approved by Engineering in charge etc complete.Specification as Directed by Engineer-in-charge etc,complete. P\P ( 90 cm x 60 cm)posters/portrait/paintingGround Floor |
| 642 | First Floor |
| 643 | Second Floor |
| 644 | Providing and supplying decorative indoor plants with decorative pot Size 1feet to 2feet etc. completeGround Floor |
| 645 | First Floor |
| 646 | Second Floor |
| 647 | Providing Mazdoor Unskilled Heavy ( Male) for regular Maintaince, sweeping work in the tahsil office building and premise as directed by engineer in charge and under supervision of Head of Department of user Department.Ground Floor |
| 648 | Providing Mazdoor Unskilled Heavy ( Female) for regular Maintaince, sweeping work in the tahsil office building and premise as directed by engineer in charge and under supervision of Head of Department of user Department.Ground Floor |
| 649 | Providing Mazdoor Semi Skill Labour for regular Maintaince, sweeping work in the tahsil office building and premise as directed by engineer in charge and under supervision of Head of Department of user Department.Ground Floor |
| 650 | Providing Mali for regular Maintaince, sweeping work in the tahsil office building and premise as directed by engineer in charge and under supervision of Head of Department of user Department.Ground Floor |
| 651 | Electrical work (Part B) |
| 652 | Providing and erecting 545 to 550 Watt Framed Dual Glass Bi-Fecial Solar Module Panel Having Mechnical Cheracterics of 2272x1133x35 (LxWxT), Weight 333 KG, Front Glass 2 mm Low Iron HTAR semi-tempered glass and Back Glass 2 mm Low Iron Printed semi-tempered glass,Having Electrical Characterics of Vmp of 41-43 Volt DC, Current 13A DC, Juncton Box IP65, MC4 Cable Connector with Sq mm, 500mm Cable including in Panel Junction Box. Bifecial Power output at 30% Rediation 700W, at Module Efficiency of 27% With 5 Years of On-Site Warrenty. |
| 653 | Providing and erecting of Transformerless Solar On Grid String Inverter of Capacity of 25KW, Having Mechnical Cherecterics of IP65 Rating, Multi Information LCD Display. Built in Wifi, DC Switch, Electrical Characterics of 1100V DC Input Voltage, Input Power of 1200W DC, MPPT Voltage Range of 200 to 950V, Startup Voltage of 180V, Nominal Output Power 25KW AC, Output Voltage of 400V, 3Ph, 5 Wire AC(3L/N/PE), Max Output Current of 15A AC, with Powerfactor Adjustable to +0.80 to -0.80. Max Efficiency 98.50% Including all Accessories like ACDB, DCDB, Wiring, Earthing, DC & AC Cables of Appropriate sizes. |
| 654 | Supplying and erecting switch disconnector fuse (SDF) 415V, 160A, with enclosure, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V , with rotary handle for ON / OFF operation(without HRC fuse) |
| 655 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 656 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010FR plywood with compliance to IS 5509:2000 |
| 657 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 658 | Supplying and erecting static energy Trivector meter 440 V 50 Hz. 20-100A ISI mark meter AC 3 phase 4 wires LCD/LED display (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested for class 1.0 accuracy by electric supply company. (Use as Solar Generation Meter) |
| 659 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 660 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 661 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 662 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 663 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 664 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 665 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 666 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 667 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 668 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 669 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 670 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. |
| 671 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 672 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 673 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 674 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 675 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 676 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (To Cover Motor Cable from Control Panel 20M Additional) |
| 677 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 678 | Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP (Borewell Depth = 60Mtr) |
| 679 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 680 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 681 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 682 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 683 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 684 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 685 | Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete. |
| 686 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 687 | Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 688 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 689 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 690 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 691 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 692 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 693 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 694 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 695 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 696 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 697 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 698 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 699 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 700 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 701 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 702 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuousrating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totalyenclosed air cooled / liquid cooled multi-cylinder diesel engine|developing suitable BHP at 1500 pm with 10% overload for 1 |hour in 12 hours, along with standard accessories,self-excited,self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltageregulation +/- 5 %, with performance class G2 and maximumfuel consumption 21.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel|base frame and mounted on anti-vibrating padswith standardcontrol panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite ACoustic enclosure as fully assembled|integral unit made of 16 SWG CRCA Sheet, sound absorbingmaterial to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 Ltr etc. onprovided M20 Grade CC Foundation complying to CPCP IVnorms with STD panel complete |
| 703 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (130394-10%=117354.60) |
| 704 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 705 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 706 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 707 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 708 | Supplying and erecting PVC insulated PVC round sheathed 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 709 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 710 | Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 6 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 711 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 712 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. |
| 713 | i) minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.ii)Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023)iii)Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. |
| 714 | i) minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.ii)Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAMiii) Supplying & erecting of High definition 4/5 Megapixel IP IR PTZ Camera with following features Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS Video Resolution: minimum 2880 x 1620 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame Rate : minimum 30 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant. Auto Tracking, Pre-set Tour Settings, Pan : 360° endless, Tilt : From -15° to 90° (auto-flip 180°), minimum Pan Speed - from 0.1°/s to 160°/s, minimum Preset Speed: 240°/s, minimum Tilt Speed - from 0.1°/s to 120°/s, minimum Preset Speed : 200°/s, Min Presets- 250, Min IR distance :150m,Lens Type : minimum 4.3 - 12.5mm Lens min 16 x digital zoom, min 30 x optical Zoom. Focus Mode : Auto/Zooming/One Push Manual, Lux sensitivity- minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance Min IR- 150m, Power Supply : support 12/24 VDC, 24 VAC & PoE, IP67/IP66, IK10, built in micro SD/SDHC/SDXC card slot minimum 256 GB, built in microphone. |
| 715 | i)minimum Input/Output : Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.ii) Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security : User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol-DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP),Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no CCTV-CAM.(NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023)iii) Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR(NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023) |
| 716 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD(NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023) |
| 717 | Supplying & erecting 43\\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON(NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023) |
| 718 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 719 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 720 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 721 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv |
| 722 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 723 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 724 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 725 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 726 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 727 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 728 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 729 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 730 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 731 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 732 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 733 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 734 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 735 | SITC of Electric Traction Passenger Lift with - Rated capacity :- 10 Passenger/680Kg - Floors :- G+2 floor (3 Stops/3 Landings) - Travel :- 3 to 4.2 mtrs- Location of Lift Machine:- MR/MRL - Rated speed :- 1.0mps VS - Car/Landing door clear opening of 800 mm wide x 2000 mm high- Clear Car size of 1300mm wide x 1100 mm deep x 2250mm high - Lift shaft available having clear size of 1900mm wide x 2000mm deep, 1500mm Pit depth, ………mm Overhead. - Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).- Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.- · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.- · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.- · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. - ARD complete with necessary SMF VRLA batteries.- Fireman controller having fireman switch at fire Landing.- CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.- · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.- · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.- · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.- · General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 736 | For Lift having 700mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 737 | Erection &Supply of high quality Static White (3000K) Linear Wall Washer in 1000mm having precies beam angle as per design or site requirement suitable for general lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. The luminaire shall have system wattage not exceeding 36W and system lumen output of not less than 2750 lumens, Beam angle should be 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full Load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : 3000K, CRI>80,, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Bridgelux to insure higher lumen output and brightness with SMD LED chips. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturere shall submit the LM79 & LM 80 report along with the supply of material along with the BIS certificate. |
| 738 | Erection & Supply of high quality RGBW Linear wall washer in 1000mm having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage not exceeding 18W and system lumen output of not less than 710 lumens, Beam angle should be narrow : 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 739 | Erection & ofSupply of high quality RGBW Linear wall washer in 500mm having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage not exceeding 18W and system lumen output of not less than 710 lumens, Beam angle should be narrow : 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 740 | Erection &Supply of high quality RGBW Floodlight projector having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 35°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 48W and system lumen output of not less than 1930 lumens, Beam angle should be narrow : 8/15/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322 ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should beCREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/ reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 741 | Erection &Supply of high quality RGBW Floodlight projector having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 35°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 24W and system lumen output of not less than 980 lumens, Beam angle should be narrow : 8/15/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322 ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should beCREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/ reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 742 | Erection &Supply of high quality RGBW Floodlight projector having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 35°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 72W and system lumen output of not less than 2895 lumens, Beam angle should be narrow : 8/15/25/40 Degree/As per site condition, The fixture shall have input voltage of 240V AC, provided with internal high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322 ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should beCREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/ reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 743 | Erection &Supply of high quality Static White (3000K) Linear Wall Washer in 1000mm having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. The luminaire shall have system wattage not exceeding 24W and system lumen output of not less than 1950 lumens, Beam angle should be 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full Load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : 3000K, CRI>80,, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Bridgelux to insure higher lumen output and brightness with SMD LED chips. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturere shall submit the LM79 & LM 80 report along with the supply of material along with the BIS certificate. Including All fixing material and Drivers. |
| 744 | Erection &Supply of LED Flexible Strip light (RGBW) with IP67 rating sealed with anti-UV and anti-UV aging silicon without color shifting. Lumen output 50Lm/W, 50Watt/5Mtr.Universal PCB width for perfect installation with aluminum profile. SMD LED's, CRI80, RGBW, 120LEDS/M, 15W/m, 24V dc, 10mm white PCB, overall width 12mm after IP rated, Supply voltage 24VDC, PCB Type: 2oz white FPC, OSP, Class III for safety use, Long lifespan 50K hrs. L70B50@25℃ , High density of LED array for dot-free linear lighting performance, better color consistency for visual comfort,. Lead cable (300mm) with suitable numbers of clip, screw, end caps , mounting tracks and waterproof connector. with 3 years warranty. |
| 745 | Erection &Supply of DMX Controller System with Standalone interfaces along with Button Panel for scene changing. Controller should deliver 512 DMX channels for entry-level budgets and shall have the options to upgrade upto 4 universe, users seeking an easy-to-operate DMX control system. Newly designed aluminium housing with beautiful finish and updated electronics that work with all the latest Pixelerr software Capable of various trigger options and equipped with DC 5-24V input. It is the perfect hardware for easy integration projects DMX Output: 512 Out channels PC and 512 Out Stand Alone. upgradtion upto 2048 Channels Input Supply: USB-C (5V-24V. DC, 0.3A). Memory: Internal memory (8 Mb, 5K to 20K DMX step capacity. ) Zones: 10 Zones, play 10 scene/sequence at time in Stand Alone. Infrared optional (scenes, play, pause, dimmer, speed) : Additional Infrared (optional) commands and additonal commands on triggers. DMX Mode: DMX In/Out, DMX Splitter x 4 ports, DMX Record, DMX Trigger Stand Alone Options: 16-bit and fine channel management, Cross Fade time between scenes, Default start scene when power up. Triggers: Real time clock and calender for each scene, Wi Light 2 Application (iOS, Android), 12 smart contact on 3-5V, Commands from contacts, UDP/ethernet triggers and commands. Max DMX outputs (USB): x12 USB interfaces connected = 12 DMX max Power: DC In USB-C 5V DC + 5-24V DC Input on Terminal Block Housing: Strong Aluminum DIN Rail cabinet, Connectors: USB-C, 3 pin Screw terminalBlockOperating Temperature: -10 to +50 C° IP Rating: IP20 |
| 746 | Erection &Supply of 6 output DMX Splitter cum Booster works as DMX signal amplifier and signal splitter. The signal amplification/boosting function should amplify the DMX master controller’s output DMX signal up to 200 meters by using an ideal DMX cable. The DMX Splitter & Amplifier’s all six output terminals are optically isolated. All six outputs should have an independent output 9V coil transformer to boost the DMX signal and capable of 24V reverse voltage protection. The Splitter/booster should be capable of working on 220V/230V line voltage AC and must have over voltage /under voltage protection. Operating temperature shall be -10 to 50 Deg Celsius. The Splitter/booster should be equipped with lightning protection. Protection Rating IP 20. Splitter/Booster should be equipped with included mounting brackets which allow multiple installation options for rack, floor, surface, ceiling mounting. Connector blocks for DMX IN and OUT connections for firm and solid DMX signal. The signal strength of DMX signal should be above 4 V at each output for reliable signal strength for a maximum of 6x32 lights in a chain and to 200 meters maximum length to the last light. Equipped with an accessible fuse carrier for surge protection and supplied with 1.5sq. mm 3 core cable pre-connected. |
| 747 | Erection &Progarmming and testing of controllers. 1. Addressing, Patching and Programming DMX Light Fixtures 2. Creating many number of sequences as per client's requirement. 3. Training of the site technicians. |
| 748 | Erection &DMX cable (single pair) having one 22AWG pair stranded (7x30) tinned copper conductors, Datalene (FHDPE) insulation, twisted pairs, overall Beldfoil shield (100% coverage) plus tinned copper braid, PVC jacketCable. Beldon make or equivalent. |
| 749 | Erection &Supply of IP67 \\"I\\" Connectors for DMX signal terminations having 3 pole cable connector, Heavy-duty, robust and strong, Integrated terminal block design. 10 AMP Current-Carrying capacity/terminal. One-piece, 3-pole in-line waterproof field assembly. Compact, therefore more options to accommodate during installation. Screw type terminals make installation easier. |
| 750 | Erection &Supply of IP67 \\"T\\" Connectors having 5 pole cable connector, Heavy-duty, robust and strong, Integrated terminal block design. 20 AMP Current-Carrying capacity/terminal. One-piece, 5-pole in-line waterproof field assembly. Compact, therefore more options to accommodate during installation. Screw type terminals make installation easier. |
| 751 | Erection &Supply of 600mm long leader cable with IP67 5-Pin Male/Female connector at one end. The Pin material should be of high quality and corossion resistance. |
| 752 | Erection &Supply of 1000mm long Jumper cable with IP67 5-Pin Male-Female connector at both end. The Pin material should be of high quality and corossion resistance. |
| 753 | Erection &Enclosure for DMX controller: Size 300 x 300 x 150 mm, plain sides, polyester, gray cover, polyester enclosures have superb temperature, UV and chemical resistance and high impact strength, Degree of protection: IP 66, Impact strenght: IK 09, Material, base: Glass reinforced polyester (GRP) Material, cover: Polycarbonate Material, gasket: Polyurethane, Colour: RAL 7035, 1 no. breather. |
| 754 | Erection &Enclosure for DMX splitter: Size 300 x 600 x 132 mm, plain sides, grey cover, Degree of protection: IP 66/ IP 67, Impact strenght: IK 08, Material, base: Fiberglass reinforced polycarbonate, Material, cover: Polycarbonate, Material, cover screws: Polyamide, Material, gasket: Polyurethane, Colour: RAL 7035, 1 no. breather. Including mounting arrangement for DMX splitter & suitable polyamide glands. |
| 755 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender