Housing Urban and Rular Development Government Departments Closing in 17 days TDR #56396199

Tender For Construction Of New Building (G+4) With Foundation Of (G+8) In The Court Premises Of Bongaon In The District Of North-24-Parganas ---- External electrical installation Work (Sub-Station & Compound Light).

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
93.10 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
17 days left
EMD
1.86 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of New Building (G+4) With Foundation Of (G+8) In The Court Premises Of Bongaon In The District Of North-24-Parganas ---- External electrical installation Work (Sub-Station & Compound Light).

BOQ

Name of Work:- Construction of New Building (G+4) with foundation of (G+8) in the Court Premises of Bongaon in the District of North-24-Parganas ---- External EI Work (Sub-Station & Compound Light).
Sl. No. Item Description
1SITC OF 11 KV VCB PANEL
2Supply, Installation, testing & Commissioning of 11 KV 800 A, short-circuit capacity of 26.3 KA for 1 sec, HT Gear with VCBs. The Vacuum Circuit Breaker should comply as per IS:13118& IEC:62271-100 for Circuit Breaker & IS:3427 & IEC:62271-200/IEC 694, IEC-61850 for Indoor panel. The HT panel is rated at 11 KV, 3-Phase 800A, Breaking Current/short-circuit capacity of 26.3kA for 1 sec, 50c/s and shall be of floor-mounting, sheet steel clad, free-standing metal enclosed air insulated switchgear cubicle with VCB inside. The Vacuum Circuit Breaker is horizontal isolation & horizontal draw out/Vertical isolation & horizontal draw out with 3 compartments and is made of 2mm CRCA sheet for load bearing members with vermin & moisture proof along with automatic shutter arrangement for complete isolation of bars, cable sockets & other live parts etc. when the removable portion is withdrawn. The breaker is arranged for hand operation through front of the panel push buttons & spring charging mechanism and also electrical motor which will be energized by 230V AC. Closing and tripping coils are rated for 110V DC to be made available from the station 400 V 3 phase 50 C/s A.C. source with remote operation compatibility. All trip coils shall be of shunt trip type energized from a suitable rectifier condenser source supply is required. There is a remote operation through multi core arrangement for closing & tripping. The shutter shall be gravity operated. (Rate Ref: All SE Committee)
3INCOMING CIRCUIT BREAKER
4a) 3 Phase Star- Star 3 limb draw type line PT 11KV/√3 /110V/√3 , 100VA Cl - 1 with fuses for primary & secondary circuit - 1 no. b) Epoxy Cast, Dual Core Delta/Y-Y CT having CT ratio 150/100/5+5 ,with CORE1:15VA Class-1.0 CORE2 -:15VA, Class-5P10, STC - 26.3ka for 1 sec- 3 nos. c) Shunt Trip Coil of 110V DC- 1 no. d) LED type indicating lamp for VCB ON/OFF, CB Trip, Springe Charge, Trip Ckt Healthy- 5 nos. e) LED type RYB Phase indication lamps-- 1 set f) Cubicle Panel illumination lamp.- 1 set g) Push Button for Emergency Trip- 1 no. h) Digital Voltmeter with Selector switch- 1 no. i) Digital Ammeter with Selector switch--- 1 no. j) Digital Multi-Function Meter- 1 no. k) Combined Numerical Relay of SCADA-compatibility incl. providing necessary software with following protection function:-50, 50N, 51, 51N, 37, 46, 46BC, 49, 50BF, 64N,68,86& 95 with programmable in-built LED indicating lamp --- 1 set. (Siemens/ ABB/ Crompton Greaves/ L&T/Alstom) l) Master Trip Relay - 1 no. m) Trip circuit Supervision relay - 1 no. n) Anti pumping relay-- 1 no. o) 6/8 Window Annunciator -- 1 set p) Local Remote/T-N-C/Motor On-Off/Heater On-Off Switch- 4 set. q) MCB for control supply-AC/DC -- 2 sets r) HRC control fuse & link as per scheme-- 1 set s) 110V DC Hooter- 1 no. t) Power Pack with 220V AC input & 110V DC continuous output should be capable of taking O-C-O operation with its battery backup. Charging unit for system, complete with suitable inter-connection with 2.5 sq.mm FRLS insulated copper conductor cable etc. as required -1 set u) Panel space heater with thermostat-- 1 no. v) Panel Illumination lamp.
5OUTGOING CIRCUITBREAKER
6a) Epoxy Cast, Dual Core Delta/Y-Y CT having CT ratio 100-50/5+5A with CORE1:15VA Class-1.0 CORE2 -:15VA, Class- 5P10. The CT should have at least 25% over capacity than total connected load. STC - 40ka for 1 sec- 3 nos. b) Shunt Trip Coil of 110V DC- 1 no. c) LED type indicating lamp for VCB ON/OFF, CB Trip, Springe Charge, Trip Ckt Healthy- 5 nos. d) LED type RYB Phase indication lamps-- 1 set e) Cubicle Panel illumination lamp.- 1 set f) Push Button for Emergency Trip- 1 no. g) Digital Voltmeter with Selector switch- 1 no. h) Digital Ammeter with Selector switch--- 1 no. i) Digital Multi-Function Meter- 1 no. j) Combined Numerical Relay of SCADA-compatibility incl. providing necessary software with following protection function:-50, 50N, 51, 51N, 37, 46, 46BC, 49, 50BF, 64N,68,86 & 95 with programmable in-built LED indicating lamp --- 1 set. (Siemens/ ABB/ Crompton Greaves/ L&T/ Alstom) l) Master Trip Relay - 1 no.(Make -Siemens/ABB/ Crompton Greaves/L&T/Alstom) m) Trip circuit Supervision relay - 1 no. n) Anti pumping relay-- 1 no. o) 6/8 Window Annunciator -- 1 set p) Local Remote/T-N-C/Motor On-Off/Heater On-Off Switch- 4 set. q) MCB for control supply-AC/DC -- 2 sets r) HRC control fuse & link as per scheme-- 1 set s) 110V DC Hooter- 1 no. t) Panel space heater withthermostat-- 1 no. u) Panel Illumination lamp.
7BUSBAR
8The spacious bus bar compartment is provided on the top of the cubicle. The main bus bar can carry current up to 1000A and are made of electrolytic grade copper & shall be vertically placed one after another. The bus bars should be air insulated but must be HT PVC sleeved & color coded for R-Y-B. No live parts should be accessible. All joints should be covered with monoplast compound and color coded for easy identification. The feeder connection to the bus bars is preferred to be encapsulated.
9FRONT DOOR
10The front door of the breaker should not be set as front. High-Voltage door during switching operations, the high-voltage door should remain closed and mechanical interlock should prevent opening of door when the switching device is in service and is switched ON. The position of the withdraw-able section, the CLOSED/OPEN switch position of the switching device, the operating cycle counter and the “spring charged” indication should be visible through pressure-resistant inspection windows in the high-voltage door. The panel front door can be closed with the breaker in isolated position. The degree of protection in the panel is IP-43 as per Indian Standard IS 3427.
11BREAKER
12The vacuum circuit breaker is mounted on a truck and is of horizontal isolation and horizontal drawout/Vertical isolation & horizontal drawout type having a robust motorized mechanism. The spring charge cycle duty of mechanism is O-C-O. The vacuum circuit breaker is single break design and has one vacuum interrupter per phase. The vacuum interrupter should not be of pinch tube type design, it should be sealed by brazing in a vacuum oven & all the vacuum interrupters must be segregated in a cast resin housing. The minimum operational life of the vacuum interrupter is 30,000 mechanical, 10,000 electrical at rated current & 100 at rated short circuit. The breaker is having auxiliary switch 6NO+6NC.
13EARTHING
14A continous copper earth bus runs across the entire length of the switchboard. All doors partitions, covers and non current carrying metallic parts are earthed to achieve earth potential for the entire enclosure. Terminals are provided at each end of the earth bus to connect the grid earthing. If integral earthing facility is not available separate earthing truck shall be provided for earthing.
15INTERLOCK
16The circuit breaker can be operated only in service/test position and not in any intermediate position, beside fully isolated condition. The circuit breaker cannot be inserted into service position in closed condition and cannot be removed from service unless it is in open condition. The circuit breaker cannot be moved from test position to service position unless auxiliary plug is engaged and auxiliary plug cannot be disengaged if the breaker is in service position. If earth switch is provided it shall be mechanically interlocked with the breaker so that both the devices can not be 'ON' simultaneously.
17METERING
18For Incoming - Digital Ammeter, Digital Voltmeter. For Outgoing - Digital Ammeter. Multifunctional Meter Type: Flush mounted, sealed dustproof construction (Front- IP5X, Rear -IP4X), multifunctional Display : Alphanumeric LCD Display having capability to Giga Display Parameters : Voltage, Current , PF/Frequency and all energy & power parameters with autoscrolling. RTC : In-built Accuracy Class : 1.0 Keyboard :Front Panel Keyboard with auto keyboard lock and passward protection for setup parameters .Communication port : RS485. Communication Protocol : MODBUS Memory : Inbuilt memory for keeping back-up of Integrted. Data. Other features - Programmable CT/PT ratio, built in phase analyzer (Make : As per manufacturer's strandard).
19Power pack with 220 Volt AC input & 110 Volt DC continuous output suitable for closing/tripping indication of HT panel Boards with 2 Nos. 12 volt 100 AH maintenance free batteries, Charging unit for trip system complete with suitable capacity digital ammeter & voltmeter i/c connections with 2.5 sqm FRLS insulated copper conductor cable etc as required.
20The panel shall be complete with power pack unit, test terminal blocks, fuses, mcbs, circuit labels, illuminating lamps in each panel, indicating lamps etc., wiring for interconnection with suitable size copper cable, suitable cable end box with cable entry from bottom for incoming and outgoing cables, HV Danger Notice board, Earth bus bars, foundation bolts and nuts etc. as required and as per direction of EIC(Make :All the accessories will be as per manufacturer's strandard).
21Two Panel
22SITC OF 11KV / 0.415 KV, 3 PHASE, 50 HZ CAST RESIN DRY TYPE INDOOR TRANSFORMER
23Supply, installation, testing and commissioning of following capacity (continuous loading) Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin Dry Type, copper wound transformer Electrolytic grade 99.9% pure copper, the core shall be built up with high grade, non-aging, low loss, high permeability Cold Rolled Grain Oriented (CRGO) Core grade MOH or better AN (air natural) cooled transformer suitable for indoor applications with Offload Tap Changer and manual operation on HV side in range of +5% to -5% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1,climate class-C1, having HV Cable End Box with terminals for connecting cable of suitable rating and LV Cable End Box with extended copper bar has to be provided for connecting multiple cable of suitable rating and complete with all accessories and safety provisions as per relevant IS Code, The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection. (Rate Ref:All SE Committee)
24Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11,incl. supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site. Design ambient condition : a) 90° C over ambient air temperature of 50ºC, Core & Coils b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level of the transformer between 55 dB to 62 dB.
25Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Lifting lugs for the complete transformer as well as for core and winding assembly; d) Bi-directional flat rollers; e) Jacking pads f) Name Rating & Diagram Plate. g) Monogram Plate. h) Additional neutral separately brought out on bushing for earthing.
26Testing: All routine tests as per IS: 2026 to be conducted, Type tests such as: Impulse test, Temperature rise test to be conducted if asked for. Manufacturer shall have in-house testing facilities.
27Losses: Conforming to ECSBC building as per ECSBC Code 2024
28500 KVA
29Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments & commissioning the installation (NS)
30SITC OF MAIN LT PANEL IN THE SUBSTATION
31SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel for framework and covers, and 3 mm nominal thickness for gland plates, including cleaning and finishing complete with 7 tank process, with short circuit withstand capacity of 31 MVA for one second, front and back openable, hinged, single shuttered, single door, with locking arrangement, good quality dust, damp and vermin proof rubber gaskets, solid connections from main busbars to switchgears with required size of Aluminium busbars, connections and interconnections and control wiring using 2.5 sq. mm of RYB colour coded FRLS PVC Insulated Copper conductor single core cables and copper cable lugs (NS)
322 no. of GI earth bus for earthing of full panel length, cable alleys, cable gland plates in two halves, dinrail for mounting switchgear, metering arrangements, drilling holes, detachable gland plates / knockout plates, providing 50 mm x 50 mm x 5 mm nominal thickness MS angle iron support for ACBs alongwith horizontal / vertical intermediate MS flat members for stiffening, mounting on MS channel iron framework 100 mm x 50 mm x 5 mm ( 9.2 kg / metre ) for floor mounting of MV panel, providing MS plate, suitable for bottom cable entry, grouting in ground, powder coating, providing and fixing the following switchgear and measuring instruments, earthing, cartage from fabricator's premises to site of work etc. as required.
33BUSBAR:- S&F of 1000 Amp capacity 99.9% - 99.5% electrolytic tinned copper (Certificate should be produced by manufacturer) with multicolor heat srinkable PVC sleeve 4 Bar Bus Bar [size of flat 4 nos 50 mm x 12 mm ] of required length mounted on non-hygroscopic porcelain insulator having sufficient di-electric strength. All interconnection/ branches should be made with required size cu bars , segregrated in two part ( Cu-bar Extensions of required shape and current carrying capacity may have to be provided at terminals of ACBs/MCCB as per direction of EIC.)
34INCOMER :- (i) 415V (Uimp=12kV peak), Icu@415V=Ics=Icw for 1 sec = 50kA, 800A, 4P Electricaly draw out type Air Circuit breaker, manually operated with interlocked doors, automatic safety shutters, mechanical ON / OFF and service / test / isolated position indicators and frame earthing contact, with microprocessor based LSIGN release having adjustable overload with time delay, adjustable short circuit with time delay, Instantaneous current, adjustable Earth fault with time delay, adjustable neutral protection - (min. 50%, 100%), test facility. The ACB should have U/V Release and at least spare 4NO + 4NC auxilary contact, 1 no. independent manual spring closing mechanism. There should be LED indicating lamp for showing R, Y, B, On, OFF, TRIP, Ready to close, & Spring charge indication on the panel door. There should be Electrical and mechanical interlock between incomers and buscouplers, conforming to IS 13947 - 2 - 1993 as amended upto date - 1 Set.
35OUTGOING
361) 415V, 630 A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-2 Nos
372) 415V, 315A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-2 Nos
383.415V, 200A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-1 Nos
394.415V, 125A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-1 Nos
405. 415V, 63A, TPN SFU with HRC Fuse unit (Make- L&T/Siemens/ Schneider)- 2 nos
41CONTROL/METERING/ACCESSORIES
42Load Manager Class 1.0 accuracy Load Manager 3 Ph 4 W 240V 5A with RS 485 port ( For measurement of V, A, F, kW, kWh ) with 3 nos. 800 / 5 Amps bar primary type CTs 15 VA burden Class 1.0 accuracy, and 3 nos. 2 Amps HRC fuse or SPMCBs 10 kA breaking capacity - 1 Set.
433 nos. phase Indication lamps LED type in RYB colours and two nos LED type lamp ON/OFF marking for each out going feeder to be fixed on panel door of each outgoing feeder.
44Danger Board - 1 No
45DG LT PANEL AT SUB-STATION PANEL ROOM
46SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel for framework and covers, and 3 mm nominal thickness for gland plates, including cleaning and finishing complete with 7 tank process, with short circuit withstand capacity of 31 MVA for one second, front and back openable, hinged, single shuttered, single door, with locking arrangement, good quality dust, damp and vermin proof rubber gaskets, solid connections from main busbars to switchgears with required size of Aluminium busbars, connections and interconnections and control wiring using 2.5 sq. mm of RYB colour coded FRLS PVC Insulated Copper conductor single core cables and copper cable lugs.(NS)
472 no. of GI earth bus for earthing of full panel length, cable alleys, cable gland plates in two halves, dinrail for mounting switchgear, metering arrangements, drilling holes, detachable gland plates / knockout plates, providing 50 mm x 50 mm x 5 mm nominal thickness MS angle iron support for ACBs alongwith horizontal / vertical intermediate MS flat members for stiffening, mounting on MS channel iron framework 100 mm x 50 mm x 5 mm ( 9.2 kg / metre ) for floor mounting of MV panel, providing MS plate, suitable for bottom cable entry, grouting in ground, powder coating, providing and fixing the following switchgear and measuring instruments, earthing, cartage from fabricator's premises to site of work etc. as required.
48BUSBAR:- S&F of 1000 Amp capacity 99.9% - 99.5% electrolytic tinned copper (Certificate should be produced by manufacturer) with multicolor heat srinkable PVC sleeve 4 Bar Bus Bar [size of flat 4 nos 50 mm x 12 mm ] of required length mounted on non-hygroscopic porcelain insulator having sufficient di-electric strength. All interconnection/ branches should be made with required size cu bars , segregrated in two part ( Cu-bar Extensions of required shape and current carrying capacity may have to be provided at terminals of SFU as per direction of EIC.)
49INCOMER :- 1) 415V, 630 A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&K/Siemens/ Schneider)-1 Nos
502) 415V, 630 A 4P On Load Manual Change Over Switch as per rating (Make- L&K/Siemens/ Schneider)-- 1 Nos
51OUTGOING
521) 415V, 630A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-2 Nos
532) 415V, 63A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-2 Nos
543.415V, 32A, TPN SFU incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Siemens/ Schneider)-4 Nos
55CONTROL/METERING/ACCESSORIES
56Load Manager Class 1.0 accuracy Load Manager 3 Ph 4 W 240V 5A with RS 485 port ( For measurement of V, A, F, kW, kWh ) with 3 nos. 630 / 5 Amps bar primary type CTs 15 VA burden Class 1.0 accuracy, and 3 nos. 2 Amps HRC fuse or SPMCBs 10 kA breaking capacity - 1 Set.
573 nos. phase Indication lamps LED type in RYB colours and two nos LED type lamp ON/OFF marking for each out going feeder to be fixed on panel door of each outgoing feeder.
58Danger Board - 1 No
59SUPPLY & LAYING OF HT CABLE IN SUBSTATION:Supplying and delivery of HT Cable, 11KV(E)/6.6KV (UE) Grade stranded aluminum conductors, XLPE insulation, semiconducting screening, and aluminum armouring for mechanical protection and PVC/FR PVC outer sheathing in combination with copper tape etc. (IS 7098 Part - 2/2011 with Up To Date Amendments.) (Rate Ref:All SE Committee)
603 core 240 sqmm [ 3 core 240 Sqmm for Supplier HT Gear to Consumer HT Gear and 1 x 3 core 240 Sqmm for Consumer HT Gear to Transformer].
61Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm (DSR P-114, Item No. 22.4.2)
62Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:a. 240 sq.mm (DSR P-116, Item No. 23.3.3)
63Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Rate Ref:All SE Committee)
644 Core 240 Sq. mm ( Transformer to Sub-Station LT Panel)
654 Core 300 Sq. mm (Sub-Station LT Panel to DG Panel)
664 Core 120 Sq. mm (Sub-Station LT Panel to Fire panel and DG panel to ICC building panel)
674 Core 95 Sq. mm (Sub-Station LT Panel to ICC building AC panel if ICC building AC panel is not fed from ICC building AC panel)
684 Core 70 Sq. mm (DG Panel to ACJM building panel)
694 Core 25 Sqmm (DG LT Panel to old ADJ-I Building )
704 Core 16 sqmm ( DG Panel to Old Server Building and Sub-Station Building)
712 core 6 sqmm (Compound Light)
72Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm (DSR P-66, Item No. 10.6.4)
73Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (DSR P-65, Item No. 10.1)
74Above 185 sq. mm and upto 400 sq. mm (DSR P-65, Item No. 10.1.4)
75Above 95 sq. mm and upto 185 sq. mm (DSR P-65, Item No10.1.3)
76Above 35 sq. mm and upto 95 sq. mm (DSR P-65, Item No10.1.2)
77Upto 35 sq. mm (DSR P-65, Item No10.1.1)
78Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (DSR P-66,Item No. 10.7)
79Upto 35 sq. mm (clamped with 1mm thick shaddle ) (DSR P-66, Item No. 10.7.1)
80Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (DSR P-68, Item No. 11.1)
813½ X 240 sq. mm (62mm) (DSR , Item No. 11.1.29)
823½ X 300 sq. mm (70mm) (DSR , Item No. 11.1.30)
833½ X 120 sq. mm (45mm) (DSR , Item No. 11.1.25)
843½ X 95 sq. mm (45mm) (DSR , Item No. 11.1.24)
853½ X 70 sq. mm (45mm) (DSR , Item No. 11.1.23)
863½ X 25 sq. mm (45mm) (DSR , Item No. 11.1.20)
874 X 16 sq. mm (45mm) (DSR , Item No. 11.1.33)
882X6 sq.mm (19 mm) (DSR , Item No. 11.1.1)
89Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. [ F6/11(d)]
9040 mm dia
9150 mm dia
9265 mm dia
93SUB STATION EARTHING:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. (Transformer Neutral Earthing) (DSR P-30, Item No. 5.6)
94Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(Transformer-Body, HT Panel, LT Panel, AMF Panel, CESC Panel) (DSR P-30, Item No. 5.4)
95Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washerexcavation and re-filling etc. as required. (DSR P-31, Item No. 5.10)
96Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (DSR P-31, Item No. 5.11)
97Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. (DSR P-32, Item No. 5.20)
98Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. (DSR P-31, Item No. 5.14)
99Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR P-31, Item No. 5.15)
100SUB-STATION SAFETY EQUIPMENT:Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required. (NS)
101a) High Voltage - size 250mm x 200mm
102b) Medium Voltage - size 200mm x 150mm
103Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222 & IS 15683 (with latest modification) and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire] (NS)
104Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire] (NS)
105Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.) (NS)
106Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc. (NS)
107Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991. (NS)
108Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre). (NS)
109Providing of rubber mat 2 mtrs Length x 1 m. wide and 2.5 mm thick class-B, Blue Color to withstand 45 KV dielectric strength as per IS 15652-2006. ( Make- Duratuf) (NS)
110Providing of rubber mat 2 mtrs Length x 1 m. wide and 2 mm thick class-A, Blue Color to withstand 30 KV dielectric strength as per IS 15652-2006. ( Make- Duratuf) (NS)
111S&F 11kv grade Rubber Hand Gloves. (NS)
112Supply of Earth Discharge Rod as per standard norms (NS)
113Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door (DSR , Item No. 2.4.1)
114Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double doo r(DSR , Item No. 2.3.4)
115Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole (DSR , Item No. 2.10.1)
116Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A (DSR , Item No. 2.12.1)
117Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A (DSR , Item No. 2.13.2)
118Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C (DSR , Item No. 1.10.3)
119Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm (DSR , Item No.1.21.1)
120Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm) (DSR , Item No. 1.27.6)
121Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch (DSR , Item No. 1.24.1)
12215/16 A switch (DSR , Item No. 1.24.3)
1233 pin 5/6 A socket outlet (DSR , Item No.1.24.4)
1246 pin 15/16 A socket outlet (DSR , Item No.1.24.5)
125Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR , Item No.1.32)
126Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (DSR , Item No.1.57)
127Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (DSR , Item No.1.17.30)3 x 6 sq. mm
1283 x 4 sq. mm (DSR , Item No.1.17.21)
1293 x 2.5 sq. mm (DSR , Item No.1.17.12)
1303 x 1.5 sq. mm (DSR , Item No.1.17.3)
131Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Rate Ref: All SE Committee (FAN) 1.2)
132Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (DSR 1.25)
133Providing and fixing M.S. Fan clamps of 16 mm dia M.S. bar, bent to shape with Hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete (DSR Civil-2014 item no. 10.17)
134Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. (DSR, 1.44)
135Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Rate Ref: All SE Committee (FAN)2.1)
136Supply & delivery of 230 V, 50 Hz, single phase, 160 watts, 15\\" (380 mm) Sweep, speed 1420 rpm, A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 3250 cmh including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Rate Ref: All SE Committee (FAN) 2.5)
137Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (DSR, 1.50.1)Upto 450 mm sweep
138Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. (DSR, 1.51)
139Supply & Fixing Timer for controlling of exhaust fan fixed on wall in MS Box with top coverand make necessary connection by S&F of FRLS cu wire as required (L&T GIC Micon225 Cat No- 2A5DT5 /equivalent Legrand). (NS)
140Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (2 way) (NS)
141Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (Rate ref: All SE Committee (LED) 4.1.1)(System lumen efficacy ≥115 lm/Watt)Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification
142Twin fittings along with S/F of 2 no. 18-20 W LED lamps as per specification(Rate ref: All SE Committee (LED) 4.1.2)
143Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lampetc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. (DSR-1.42)
144Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube / lampetc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.(DSR-1.41)
145S & F 9 watt B C type LED lamp (NS)
146COMPOUND LIGHTING SYSTEM:LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt).Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). ( Sub-Station Building - 10 nos, Main Building- 5 Nos.) (DSR P-51, Item No. 8.13)
14790 Watt (DSR P-51, Item No. 8.13.14)
148Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint (NS)
149S&F of 240V double door Timer DB [equivalent of 2+10 SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 240V, 25 A DP MCB , 1 no. 240V, 25A, DP Power Contactor, 1 no. Digital time switch-24 hrs with minimum switching of 15 minutes, 2 nos. 240V, 25A SP MCB ('C' Curve 10kA) with inner-outer plate & internal wiring by suitable size of Cu wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement as directed by EIC. [Make : L&T/ABB/Legrand] ( For Outdoor Light Control ) ( 1-Sub Station Building - 1 no, Main Building- 1 no.) (NS)
150Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1512 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR Item No. 1.14.1)
152Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes3 x 1.5 sqmm (NS)
153S.I.T.C OF LED GLOW SIGN BOARD:SITC of LED illumination sign board fabricated by ACP box supported with 1\\"x1\\" MS hollow square pipe of 18swg all around. The 3mm ACP facial should be provided with Laser cutting 6mm thick acrylic letter out of which 3 mm rising from the surface of the ACP board. 6mm letters should be fixed on another 3 mm acrylic sheet on back side of the ACP facial. Border line of the front portion and back portion should be coverd by 1.5\\" aluminium channel as per the direction of EIC. The Sign board should be glow from back side of letters by 1.5W/2.0 LED 2/3/4 module cool white in colour inculding 12 Volt 615W power supply and LED must be covered in box made of 3 mm thick sun board 4\\" with part of the four side of board should be covered by ACP after bending excess part from front side. The sign board should be fixed on roof of the building with suitable supporting arrangement on floor through angle iron frame of adequate (NS)
154dimention as necessary for mechanical strength to hold the structure & inclusive penting and mending good damages as per direction of EIC. Colour of APC & letter will be as per direction of EIC.The cost transpotation and scafolding charges are included. The sign board should be as per the following inscription as per direction of EIC – Probably to be provided (I) national emblem. (II) State logo. etc. beside these the probable (actual as per authority approval) matter would be as follows:- Integrated Court Building Bongaon Court ComplexBongaon, North 24 ParganasGovt. Of W.B.Bongaon Court ComplexBongaon, North 24 ParganasGovt. Of W.B.
155Supply & fixing of angle iron frame fabricated from 40 mm x 40 mm x 5 mm thick square four nos hollow bar with cross and radial support including one no 40x40 mm angle iron support in the middle for the Sign board of size 16 ft x 4 ft with suitable three nos. cross angle support welded with 4 nos angle hook in equal space for fixing on the structure with all necessary welding and fabrication. The structure shall rest in both sides with proper welding as per instruction of EIC.
156Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. (PWD 2017)
157i) 1st coat of aluminium paint over one coat of RO priming [H2/7B/a]
158ii) 2nd coat of aluminium paint over 1st coat [H2/7B/b]
159(A) Total Say Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56396199
AUTHORITY Government Departments
TENDER VALUE 93.10 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of New Building (G+4) With Foundation Of (G+8) In The Court Premises Of Bongaon In The District Of North-24-Parganas ---- External electrical installation Work (Sub-Station & Compound Light).
Basic Detail
Tender No WBPWD/SESEC/eNIT-03/26-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 09 Jul 2026
Submission Date 28 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 93.10 Lakhs
Tender Fee Ref. Documents
EMD 1.86 Lakhs
Exemption Not Available
Document List
36bbbe72-aa0f-46bf-b4b7-b986d202a2d9.html
BOQ_5086251.xls
Tendernotice_1 (15).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

36bbbe72-aa0f-46bf-b4b7-b986d202a2d9.html

xls

BOQ_5086251.xls

pdf

Tendernotice_1 (15).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders