Public Administrative Department Local Bodies Closing in 6 days TDR #56395806

Tender For Provision Of G.I. Pole And Semi High Mast Pole With Led Lights At Road From St. Stephon College To Petrol Pump, Malka Gunj In Ward No. 12 (Malka Gunj) Under Civil Line Zone.

Issued by Local Bodies · Delhi, Delhi
Tender Value
20.94 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
6 days left
EMD
41900
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of G.I. Pole And Semi High Mast Pole With Led Lights At Road From St. Stephon College To Petrol Pump, Malka Gunj In Ward No. 12 (Malka Gunj) Under Civil Line Zone.

BOQ

Name of Work:- Provision of G.I. Pole and Semi High mast Pole with LED Lights at Road from St. Stephon College to Petrol Pump, Malka Gunj in Ward No. 12 (Malka Gunj) under Civil Line Zone.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. (a) 100 A, 16 KA, TPMCCB
3(b) 200 A, 25 KA,TPMCCB
4Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
6Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
7Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. (a) 3 output (1output per phase) and suitable for three phase supply
8LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm /Watt). Supplying, Installation, Testing & commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 72 Watt
9LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 100 Watt
10Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Upto 35 sq. mm
11Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm
12Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (a) 63 mm· dia (OD-63 mm & ID-51 mm nominal)
13Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
14Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
15Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
16Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
17Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
18Fabrication, supply & erection of 8.0 mtr height, minimum 3 mm thick, bottom dia of 130mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor 4 nos. & shorting links on DIN channel i/c providing and fixing DIN channel of suitable length, 6 Amp. SPMCB 'C' Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS code etc as required.
19Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm (L) x600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1160 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia-1600 mm (approx) -8 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 20mm dia, 700/750 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 7m and 8 mtr pole.
20Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required.
21Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame, 2 point suspension system with steel wire rope 5mm dia. (7/19 construction) single drum winch, galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries symmitrically And its control gears boxes and lighting finial, the mast shall have integral type manual raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC(1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in possion, reinforcement of cold twisted barsof 12 mm dia-2100mm long(approx)-16 nos. and reinforcement of cold twisted bars of 8 mm dia-3700 mm (approx)-13 nos. (with 150mm specing ) as required with positioning of foundation bolts and providingDWC HDPE pipe for cable entry and exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB, 63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
22Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
23SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
24Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : (a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56395806
AUTHORITY Local Bodies
TENDER VALUE 20.94 Lakhs
LAST DATE 17-07-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of G.I. Pole And Semi High Mast Pole With Led Lights At Road From St. Stephon College To Petrol Pump, Malka Gunj In Ward No. 12 (Malka Gunj) Under Civil Line Zone.
Basic Detail
Tender No EEE-II/TC/2026-27/09.1
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 09 Jul 2026
Submission Date 17 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 20.94 Lakhs
Tender Fee 590
EMD 41900
Exemption Not Available
Document List
BOQ_330769.xls
fac48264-6906-4846-b176-db7f476ee05f.html
GeneralConditionsCMDF.pdf
MCD_GCC_2026Latestcirculars.pdf
SHMP.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_330769.xls

html

fac48264-6906-4846-b176-db7f476ee05f.html

pdf

GeneralConditionsCMDF.pdf

pdf

MCD_GCC_2026Latestcirculars.pdf

pdf

SHMP.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders