Tender For Dismentaling ,Shifting And Reassembling And Repairing , Servicing ,Itc Of Different Capacity Dg Sets From Sajan Nagar,Shehnai Residency,Choti Gwal Toli,Palasia,Moti Tabela,Sch 140 To Different Sites Of Ba Indore.
Tender Overview
Project Description
Tender for Dismentaling ,Shifting And Reassembling And Repairing , Servicing ,Itc Of Different Capacity Dg Sets From Sajan Nagar,Shehnai Residency,Choti Gwal Toli,Palasia,Moti Tabela,Sch 140 To Different Sites Of Ba Indore.
BOQ
| Sl. No. | Item Description |
| 1 | Dismentaling of DG set upto 20 KVA with canopy/without canopy at TE/ BTS site with all accessories i.e.canopy,Engine, alternator, control panel,cable, pipe,exhaust, earthing strip etc as reqd. |
| 2 | Shifting of dismentaled DG set upto 20 KVA with all accessories by manual/crane i.e. canopy,Engine, alternator, control panel,cable, pipe etc from above ground floor to ground floor comp etc. As reqd. |
| 3 | Loading, unloading & Transportation of the above dismantelled DG sets with all accessories upto 70 KVA Comp etc as reqd. |
| 4 | Upto 20 KM |
| 5 | Above 20 KM and Upto 100 KM |
| 6 | More Than 100 KM and Upto 150 KM |
| 7 | Assembling and installation of this Dismetaled DG sets upto following capacity at destination station i/c canopy,Engine, alternator, control panel,cable, pipe etc i/c hardware, Miscellenious wiring, gas welding etc. As reqd.(Diesel should be arrange by agency for testing of min. 2.0 hrs) |
| 8 | Upto 20 KVA |
| 9 | Pdg. & Making of General Servicing of the following capacity DEA sets of different make and model installed at TE/BTS Sites comprising of following jobs i/c fare and labour charge including complete checking of DEA Set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd.(a ) Cleaning the bowl inside as well as out side of fuel filter and oil filter.(b) Cleaning the fuel strainer with clean diesel i/c pressure testing of fuel injector and it should be as per manufacturer recommendation.(c) Cleaning the cooling system (Radiator i/c fins)(d ) cleaning of Air cleaner element.(e) Checking all belt Drives and re-tensioning the same etc. as reqd.(f ) Remove the tappet cover and checking the valve clearance gap between rocker arm toe and valve stem end in cold condition as per manufacturer ( g ) Cleaning the entire E/A Set (inclusive blower and block). i.e. oil & grease etc.(h) Cleaning of diesel tank(i ) Checking of charging alternator, starter self and engine control panel connection, gauges and indicators and its fuction.(j) Checking and setting of fuel supply and time as per manufacturer recommendations NOTE: After servicing the of DEA set, a trial test also be carried out by the firm for checking its performance dully verified by concerned telecom authorities. |
| 10 | up to 20 KVA DEA set |
| 11 | Replacement of the following Parts / Items in existing Various capacity DEA sets of different make ,model I/c dismantling of faulty parts, fixing the new in place of faulty parts , testing etc. as reqd. (Note- Make and Model as per manufacturer recommendation) |
| 12 | Oil Filter Element ( 1/2 Litre ) |
| 13 | Diesel Filter Element Set ( 1/2 Litre ) |
| 14 | Lubricating Oil Multi Grade ( 20 W 40) ( Make- Servo,Castrol,Volvoline, Kirloskar, Greaves OR similar superior Make) |
| 15 | Steel wire braided fuel pipe with benjo bolts & washer |
| 16 | Battery Leads Red & Black 0.6 mtrs Length & Size 16 AWG flexible copper silicon battery lead i/c 02 brass terminals & thimbles. |
| 17 | Radiator Coolent Pre Mix ready to use (Make -kirloskar /HP/Fleetguard OR similar superior Make) |
| 18 | V belt |
| 19 | Set of gasket |
| 20 | Air filter suitable for DEA set upto 63 KVA |
| 21 | Air filter suitable for DEA set abvove 63 KVA |
| 22 | Hose pipe set i/c clamp at both side |
| 23 | Replacement of the following Parts/ Items in existing Different capacity and make DEA Set AMF/ Manual Control Panels I/c Dismantling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd. ( Make - Teknica , VNT, National or Similer Superior Make ) |
| 24 | SMPS Battery Charger 12 volt DC 10 Amps complete as required etc. |
| 25 | Repalcement of Feed pump assembly complete, suitable for existing DEA set including dismentalling of faulty / defective part and fixing with new one i/c Testing etc. complete as reqd. |
| 26 | Calibration of fuel injection pump (FI pump) i/c dismentalling of FI pump for repairing, cartage to the service station and refixing the same i/c injector timing & tappet setting, testing etc. complete as required.Note: Callibration of feul pump to be done from authorise dealer and test report should be submitted. |
| 27 | Upto 2 cylinder engines |
| 28 | Upto 4 cylinder engines |
| 29 | Repairing of cylinder head [if required] to stop the leakage and S/F of head gasket and repositioning of head (per head) etc. complete as reqd. |
| 30 | Supplying and fixing of 12 Volts engine starting self as per manufaturer recommendations i/c dismentelling of old deffective/worn out starting self i/c fixing,connetion testing etc. complete as reqd. |
| 31 | Providing and making general servicing and repairing of 12 Volts Engine starting self i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of housing of the self with petrol , replacement of carbon brushes by new one etc complete checking of self and testing and refixing with proper alignment with gears etc complete as reqd. |
| 32 | Repairing & servicing of the existing faulty radiator in existing DEA set by repairing of leakage and cleaning of copper tubes with the help of cleaning agents, dismentalling of radiator assembly including transportation, brazing and testing for leakage and reinstallation after repairing the same etc. complete as required |
| 33 | Upto 50 KVA DEA set |
| 34 | Replacement of the faulty Parts in the existing Alternator i/c dismantling the faulty, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd. |
| 35 | AVR Make National or Similer Superior Make |
| 36 | Rectification of defects in DEA panel wiring with the help of petty nature consumables and wires including cleaning and testing and make the panel operational etc. complete as required. |
| 37 | Supplying and Fixing of 12 Volts Lead Acid Maintenance Free Battery of following capacity for E/A sets, i/c complete initial charging, battery terminals, transportation, testing, commissioning etc. complete as reqd. (M/S Exide, Amron or Similar superior Make) |
| 38 | 88 AH Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents