Tender For Shifting Of 11 Kv Line For Construction Of S.B. Over Samakoi Nallah On Sapjhara To Sarei Under Pallahara Sub-Division Of R.W. Division, Angul
Tender Value
18.72 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
12 days left
EMD
18726
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sambalpur → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Shifting Of 11 Kv Line For Construction Of S.B. Over Samakoi Nallah On Sapjhara To Sarei Under Pallahara Sub-Division Of R.W. Division, Angul
BOQ
| Sl. No. | Item Description |
| 1 | PSC POLE 10 METER LONG 330 KG. |
| 2 | PSC Pole Clamp(GI) |
| 3 | Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 4 no's Channel(GI)required =( 4x9.56x1.2) |
| 4 | Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 16 no's required = (16x2.36x0.280) |
| 5 | Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.306 mtr., 4 no'sChannel(GI) required =( 4x9.56x0.306) |
| 6 | Danger Plate, 1 no's. |
| 7 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's =(1x0.59x0.510) |
| 8 | GI barbed wire anticlimbing device 3 Kg. Per support |
| 9 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's= (4x0.59x0.510) |
| 10 | 11 KV pin insulator polymer |
| 11 | H W fitting(B&S) 70KN, 3Bolt |
| 12 | Disc insulator (B&S) 70 KN polymer |
| 13 | Earthing of Support ( Coil Type ) |
| 14 | No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing |
| 15 | NON METALLIC TIES -11KV 55SQMM CVRD AAAC |
| 16 | IPC for 55 sq.mm AAA conductor (For covered conductor)-11kV |
| 17 | Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in eachPole ) |
| 18 | H.T. Stay clamp, 50x8 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair) |
| 19 | H.T. Stay set (Complete ) |
| 20 | H.T. Stay Insulator Type-C |
| 21 | 7/10 SWG Stay Wire 15kg /stay |
| 22 | GI Nut , Bolt & Washer of different sizes (7.433 Kg each Cut Pole) |
| 23 | Black Paint(GIS Numbering & Zebra Stripping) |
| 24 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 25 | Fixing of complete 11KV line Complete stay set includes1) Turn Buckle Assembly2) Stay Rod & Stay plate3) Stay Insulator4) Stay Wire.5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard. |
| 26 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1667mm) = 0.42Cu.mtr(Per Pole) |
| 27 | PSC POLE 10 METER LONG 330 KG. |
| 28 | PSC Pole Clamp(GI) |
| 29 | 11 KV V cross Arm(GI) (10.2 K.g. each ) |
| 30 | Top bracket 100x50X6 mm GI Channel(GI) (2kg each) |
| 31 | Danger Plate, 1 no's. for each pole |
| 32 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's =(1x0.59x0.510) |
| 33 | GI barbed wire anticlimbing device 3 Kg. Per support |
| 34 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's= (4x0.59x0.510) |
| 35 | 11 KV pin insulator polymer, 3 Nos. required for each support |
| 36 | Earthing of Support ( Coil Type ) |
| 37 | No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing |
| 38 | GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point) |
| 39 | 55 sq.mm XLPE Insulated AAA conductor |
| 40 | Black Paint(GIS Numbering & Zebra Stripping) |
| 41 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 42 | NON METALLIC TIES -11KV 55SQMM CVRD AAAC |
| 43 | Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in eachPole ) |
| 44 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1667mm) = 0.42Cu.mtr(Per Pole) |
| 45 | Guarding Channel(GI) 75x40x4.8 mm, 7.14 KG/Mtr., each Channel(GI)length 2.2 mtr., 4 no's Channel(GI) required =( 4x7.14x2.2) ( For Single Pole) |
| 46 | No-6 GI wire (0.192 kg/mtr.) for Main String |
| 47 | No-8 GI wire (0.131 kg/mtr.) for lacing |
| 48 | Eye Bolt (236mm, 16mm dia, 1.577kg/mtr.) |
| 49 | Gi Pipe Earthing 40mm. 3 Mtr. Long |
| 50 | 50x6mm Flat(GI) for earthing, 2.36kg/mtr., (10.7 mtr For raising)= 10.7x2.36 |
| 51 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe . |
| 52 | 14 Mtr. Long H-Pole(GI) (Total weight with Base Plate & Stiffner= 782.67 KG) |
| 53 | Top Channel(GI) 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 3 mtr., 8 no's Channel(GI) required =( 8x9.56x3) |
| 54 | Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 24 no's required = (24x2.36x0.280) |
| 55 | AB switch Mounting Channel(GI) 75X40X4.8mm, 7.14KG/Mtr, each Channel(GI) length 3 Mtr., 2 no's Channel(GI) required =( 7.14x3x2) /AB Switch |
| 56 | AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required =( 9.56x2x0.35) /AB Switch |
| 57 | Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1) /AB Switch |
| 58 | Pole Belting Channel(GI) 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 3.0 Mtr., 8 no's Channel(GI) required =( 7.14x3x8) |
| 59 | 50x50x6mm.GI Bracing Angle(GI), 4.5Kg./mtr., each Angle(GI) length 3.512 mtr., 8 nos Angle(GI) required = (4.5x3.512x8) |
| 60 | Danger Plate, 2 no's. |
| 61 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510) |
| 62 | Gi Pipe Earthing 40mm. 3 Mtr. Long |
| 63 | 50x6mm Flat(GI) for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 5 mtr. For raising)= 23x2.36 |
| 64 | GI barbed wire anticlimbing device 3 Kg. Per support, 4 no's qty. required =(4x3kg) |
| 65 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 16 no's = (16x0.59x0.510) |
| 66 | Lightning Arrester(12KV,10KA) (Station Class,class-2) |
| 67 | AB Switch (11KV,400A.3pole,50Hz) |
| 68 | 11 KV pin insulator polymer |
| 69 | H W fitting(B&S) 70KN, 3Bolt |
| 70 | Disc insulator (B&S) 70 KN polymer |
| 71 | WEDGE CONNECTOR FOR 100 SQ MM CONDUCTOR. |
| 72 | Paddle clamp for wedge connector of 100 sq.mm AAA conductor |
| 73 | 100 SQ.MM. AAAC XLPE Covered Conductor-11kV |
| 74 | GI Nut , Bolt & Washer of different sizes |
| 75 | POLYCARBONATE BIRD GUARD |
| 76 | Black Paint(GIS Numbering & Zebra Stripping) |
| 77 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 78 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX2300mm) = 0.58Cu.mtr(Per Pole) |
| 79 | Couping ratio 1:1.5:3(M-20 Grade) with dimension ( 500X500X450)= 0.1125 Cu mtr(Per Pole) |
| 80 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding ofFlat(GI) around pipe . |
| 81 | Dismantling of 9/8 Mtr. PSC |
| 82 | Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender