Tender For Providing Internal And External Electrification, Split Type Ac Unit And 40 Kva Dg Set To Ware House For Proper Storage Of Evms & Vvpats In The Master Plan Complex At Veeracholapuram In Kallakurichi District.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
15 days left
EMD
32500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kallakurichi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Internal And External Electrification, Split Type Ac Unit And 40 Kva Dg Set To Ware House For Proper Storage Of Evms & Vvpats In The Master Plan Complex At Veeracholapuram In Kallakurichi District.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End |
| 2 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End |
| 3 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb. |
| 4 | Supply and fixing of single box type fitting with TW round block on wall or ceiling with 20W LED Tube Light for T8 Fitting (Single Side) with PVC unsheathed copper leads from terminals to the fitting. Higher end |
| 5 | Supply and fixing of Twin box type with 2 Nos 4'20 W LED tube light fitting with TW round blocks on 0.75 mtr conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals to the fitting with LED tube. |
| 6 | Supply and fixing of 34W LED 2 x 2 Square type recessed fitting complete with LED on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 7 | Supply and fixing of 10W LED Gate Light fitting on the existing post / wall with PVC unsheathed copper leads. (Higher End) |
| 8 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting. |
| 9 | Supply and fixing of 65 mm dia. (2 -1/2\\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Lower end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed FRLS copper leads from SMC box to fitting and with painting of suitable colour. |
| 10 | Supply and fixing of 50W LED flood light fitting on the suitable angle frame with Connection. (Higher End) |
| 11 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp. |
| 12 | Supply and fixing of 375mm (15\\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. |
| 13 | Supply and fixing of louver shutters arrangements for 375mm (15\\") sweep (light duty) AC exhaust fan. |
| 14 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. |
| 15 | Supply and fixing of louver shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan. |
| 16 | Supply and fixing of 1 no. 6/16A two module socket, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End |
| 17 | Supply and fixing of 3nos. 6A two module 3 pin socket, 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End |
| 18 | Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection. (For AC Plug) |
| 19 | Supply and fixing of 32A DP MCB in flush with sheet enclosure in wall with connection. (For Street light and UPS In and out) |
| 20 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End |
| 21 | Supply and fixing of Three phase Seven Segment type 4 way 63A distribution board with Metal Door cover Code IP42 Protection , with 63A 4 pole ELCB 30 mA as incoming and Sub incomers 3 Nos 40A DP ELCB and 12Nos 6-32A SPMCB as Outgoing on Wall with earth connection only. The MCB DB and MCB’s should be with ISI mark. |
| 22 | Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB , 15 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End |
| 23 | Supply and fixing of 100A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with Earth connection only. |
| 24 | Supply and fixing of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2\\" x 1-1/2\\" x 1/4\\" rigidly fixed on wall covered with hylam sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\\" x 1/4\\" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. |
| 25 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. |
| 26 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour. |
| 27 | Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour. |
| 28 | Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour. |
| 29 | Supply and run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. |
| 30 | Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed position. |
| 31 | Supply and clamping of 3-1/2 x 50 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. |
| 32 | Supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 33 | Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection. |
| 34 | Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. |
| 35 | Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 36 | Supply and clamping of 4 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. |
| 37 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
| 38 | Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 39 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 40 | Supply and erection of Indoor units of 2 Ton capacity (3 Star Rated) Split type Airconditioner unit confirming to ISI 1301 (Part-2) 1992 with amendment No.1 fitted with Hermetically sealed compressor operation on 230 V 50Hz AC Supply system with energy efficient operating system with refrigerant gas R-22 suitable for high wall mounting evaporator and specification as under general requirement interconnection of pipes and cables. (Make : Blue Star, Carrier, Voltas) (3 star rated) |
| 41 | Supply and erection of 5 KVA Capacity Automatic voltage stabilizer suitable to operation on 230 Volts, single phase, 50Hz, AC supply system with time delay relay and High/Low voltage cut off, input voltage range 170V to 270V single phase, wall mounting type stabilizer with necessary clamp. (Make : V-Guard) |
| 42 | Supply and laying of 5/8\\" and 3/8\\" Copper Pipe. (Extra beyond 3 metres supplied with AC unit. |
| 43 | Supply and fixing of water drain pipe line. (1\\" PVC pipe) |
| 44 | Supply and fixing of Ms stand for fixing outdoor unit. |
| 45 | Supply, Installation, Testing and commissioning of 15 KVA UPS system 3 phase input and Single phase output and as per the detailed specification enclosed, Sealed Maintenance free batteries to support 15 KVA for 2 hrs backup complete with intercell connectors & copper cables, battery stand made out of powder coated MS Angles with adeguate support to carry the load of the batteries. The vendor shall submit dimensional GA drawing of complete UPS/ Inverter system battery rack with batteries, Service panel and battery bank calculation. |
| 46 | Supply , Testing Commissioning and Handing over of 1 No 40 KVA Diesel Generator Set with acoustic enclosureconforming to CPCB IV+ Norms and BISSpecifications With AMF Panel Diesel Generator set of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity comprising of Engine developing 52.4BHP water cooled clockwise rotating feed pump with 36KW/40 KVAoperating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges.(A) Engine: Water cooled diesel engine suitable for Generator application with a shaft out put of 52.4 BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, aircleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc.(B) 12/24 Volt Electronic starting Equipment:Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length.(C) ENGINE INSTURMENT PANEL / MOUNTED:Starting push button / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechanical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load.(D)ALTERNATOR:40 KVA/36 KW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to IS:13364 (Part-II)/ 1992 to be means of coupling. |
| 47 | (E) AMF CONTROL PANEL:The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel.1. AC Ammeter and selector switch.2 . Voltmeter and selector switch.3. 3 Nos current transformer with suitable ratio 4. Frequency meter 5. KWH meter6. 1 No power factor meter 7. Battery charging set comprising of the following for charging the battery from mains. Transformer / Rectifier |
| 48 | b. DC Ammeterc. DC Voltmeterd. ON / OFF switche. Charging rate selector switchf. push button startg. push button stoph. push button reset8. 1 set Air break contactor with auxiliary neutral contactor for main supply 9. 1 set Low voltage HRC fuse for the short circuit protection of the main supply 10. 1 set Alternator contactor with auxiliary neutral contactor. 11. 1 set Three pole bimetal release for over load protection of alternator 12. 1 set low voltage HRC fuse for the short circuit protection of the alternator 13.1 set DC control relays incorporating engine start/ stop and failure to start / lockout 14. 1 set selector switch auto/ manual15. 1 no Push button \\"Start\\" 16. 1 no Push button \\"Stop\\" 17. 1 no Push button \\"Reset\\" 18.1 No signal lamp for indicating load on mains 19. 1 no signal lamp for indicating load on set. 20.1no signal lamp for indicating set fails to start. 21.1no signal lamp for indicating set running. 22.1No signal lamp for indicating battery 23. 1set Pilot lamps of 3 nos |
| 49 | 24. MCB of 63A capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch.25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with heat shrinkable PVC sleeves. 26.1No mains voltage monitor 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L. 28.1set Timers 29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressureb) High water temperaturec) Over speed 30.1No Earth fault relay31.Isolator to isolate the neutralNote:- 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements.2. The engine should trip for the following: a) Low lubricating oil pressureb) High water temperature c) Over speed 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service with 63 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANKFuel tank of 200 litres capacity and with inlet and outlet connections, level indicator with scale etc. |
| 50 | G.BASE FRAME:Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generator set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment.H) ACOUSTIC ENCLOSURE:The Acoustic enclosure, Self standing weather proof KG- CPCB Typed Acoustic canopy KG 250WS floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions. Erection of acoustic enclosure suitable for 40 KVA Diesel generator complete with all accessories as above and suitable supports etc. 1. Supply of manuals for operation & maintenance of DG set with warranty card etc. |
| 51 | Erection of Gen set:-Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion around the foundation erection of 40 KVA Generator set over the existing foundation and erection of Generator set with proper alignment over the existing foundation to suit 40 KVAGenerator set Foundation size L4200xW1600xH200mm. |
| 52 | Supply and installation of exhaust piping of sufficient length with suitable MS pipe so as to extend outside the generator room with necessary thermal insulation |
| 53 | Preparation of Electrical schematic diagram, site plans, physical layout 5 copies and payment of CEIG fees submission of completion report, rectification report, obtaining drawing approval, safety certification etc., |
| 54 | Supply of Hikvision IP Bullet Camera 2MP (1280 x 960) high resolution IR Bullet• HD video output • Low illumination 3D DNR & DWDR & BLC • IP66 rating• IR range: up to 30m • True day / night 1/3\\" Progressive CMOS, ICR, 0.01lux/F1.2 | 1280x960: 25fps (P)/30fps(N) 6mm/F2.0 lens (4mm) | H.264 / MJPEG | dual-stream, DWDR | 3D DNR | BLC | IR range: up to 30m | DC12V & PoE | IP66 | Bracket included Make :Hikvision ,dahua, |
| 55 | Supply and installation of 4U Metal Rack with front glass door, Lock and Key, also with power manager. |
| 56 | Supply and Installation of Switch 8 port POE switch for CCTV IP camera with accessories. Make: Hikvision / equivalent. |
| 57 | Supply and installation of 16 channel 2-SATA NVR - (Network Video Recorder). Up to 16 channel IP cameras can be connected. Supports decoding .265+/H.265/H.264+/H.264 video formats. Up to 4K high-definition live view, storage and playback. Up to 8-ch @ 1080p decoding capacity. Up to 160 Mbps high incoming bandwidth ensures IP cameras can be connected. 1 HDMI and 1 VGA interfaces: both interfaces support independent video output. 2 HDDs for continuous video recording.Make: Hikvision |
| 58 | Supply and installation of following Category 6 patch panel with individually removable information outlets with rear cable management tray24Port Rj 45 Jack Panel (AMP) |
| 59 | Supply and fixing of RJ 45 I/O box. |
| 60 | Supply and Installation of PVC Pipe With accessories. |
| 61 | Supply and run of Cat-6 cable in existing PVC rigid pipe on wall and ceiling. |
| 62 | Supply and fixing of 4TB hard disk. |
| 63 | Supply and Installation 40\\" LED TV With Mini PC. |
| 64 | Supply and installation of following 4U inch width rack for ethernet switches with A.C. distribution box, wire manager, fan tray, lockable front tinted glass door and two pair angle to support the switch installed in the 6U rack. |
| 65 | Supply and Fixing GI Pole 10 Ft With accessories. |
| 66 | Supply and Installation 1kv 230V UPS. |
| 67 | Supply and Fixing of 3600 ANSI Lumens Projector, XGA (1024X 768 ) Resolution, Contrast Ratio: 20000:1 |
| 68 | Supply and Fixing of motorised screen 10' x 8'. |
| 69 | Supply and Fixing of 3 feet ceiling mount kit. |
| 70 | Supply and run of 20 Metre HDMI Cable. |
| 71 | Supply and run of 3 Core 1.5 sq.mm. PVC Power Cable for Projector. |
| 72 | GST @ 18% |
| 73 | Supply of Diesel to run the Generator Set for a Minimum of 8 hours. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender