Tender For Electrical Works In Cnc, Electrical System Upgrade-Mb, And Supply Installation Testing and Commissioning of 2No.S 20 Kva Online Ups At Pragati Bhavan
Tender Value
78.18 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
5 days left
EMD
1.56 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Works In Cnc, Electrical System Upgrade-Mb, And Supply Installation Testing and Commissioning of 2No.S 20 Kva Online Ups At Pragati Bhavan
BOQ
| Sl. No. | Item Description |
| 1 | Electrical System Upgrade – Replacement of Existing Cables and Distribution Panels at Main Building |
| 2 | Supplying and fixing 3 phase 8 way (8+24) double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 250 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB) |
| 3 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 4 | 125 A,36KA,FPMCCB |
| 5 | Supplying and fixing 40 A to 63 A rating, Triple Pole 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing DB/Enclosure complete with connections, testing and commissioning etc. as required. |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of 3 pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 7 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle OR L-clamps for supporting/holding the tray, GI bolts & nuts, fastner etc,the supports shall be securely anchored using approved chemical anchoring system (epoxy resin anchor bolts) of reputed makes such as HILTI or equivalent approved make, including threaded rods, base plates, and angle supports as required. |
| 8 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 9 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle OR L-clamps for supporting/holding the tray, GI bolts & nuts, fastner etc,the supports shall be securely anchored using approved chemical anchoring system (epoxy resin anchor bolts) of reputed makes such as HILTI or equivalent approved make, including threaded rods, base plates, and angle supports as required. |
| 10 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 11 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle GI bolts & nuts, fastner etc,the supports shall be securely anchored using approved chemical anchoring system (epoxy resin anchor bolts) of reputed makes such as HILTI or equivalent approved make, including threaded rods, base plates, and angle supports as required. |
| 12 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 13 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle GI bolts & nuts, fastner etc,the supports shall be securely anchored using approved chemical anchoring system (epoxy resin anchor bolts) of reputed makes such as HILTI or equivalent approved make, including threaded rods, base plates, and angle supports as required. |
| 14 | 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 15 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt ) as required. |
| 16 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 17 | Supply of suitable amount of earthing compound (EXCEL compound or equivalent) etc. as required. |
| 18 | Supplying and fixing 8 SWG copper wire on surface or in recess for loop earthing as required. |
| 19 | Supplying and fixing 6 SWG copper wire on surface or in recess for loop earthing as required. |
| 20 | Supplying and fixing 10 SWG copper wire on surface or in recess for loop earthing as required. |
| 21 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 22 | Above 185 sq. mm and upto 400 sq. mm |
| 23 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 24 | Above 185 sq. mm and upto 400 sq. mm |
| 25 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 26 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 27 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 28 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 29 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 30 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 31 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 32 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 33 | Supply of following sizes of PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)1988 |
| 34 | 4X16sqmm |
| 35 | 4X25 Sq.mm |
| 36 | 4X70 Sq.mm |
| 37 | 4X150 Sq.mm |
| 38 | 4X240 Sq.mm |
| 39 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 40 | 3½ X 25 sq. mm (28mm) |
| 41 | 3½ X 35 sq. mm (32mm) |
| 42 | 4 X 16 sq. mm (28mm) |
| 43 | 4 X 25 sq. mm (28mm) |
| 44 | 4 X 70 sq. mm |
| 45 | 4 X 150 sq. mm |
| 46 | 4 X 240 sq. mm |
| 47 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. and labelling the DB |
| 48 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 49 | Supplying installation, testing and commissioning of free-standing indoor compartmentalized cubicle type panel suitable for 415 V, 3phase, 4 wire 50Hz AC supply system fabricated in CRCA sheet steel of 14-gauge thick, detachable gland plates of suitable size at the bottom for cable entry, and busbar chamber with tinned copper bus bar of 630A capacity, handle, gaskets etc. including powder coat painting in approved shade, ISMC channel at bottom, entire panel shall have a common tinned copper earth bar of size 20 mm x 3mm at the rear with 2 nos earth stud, solid connections from switch gears with required size of copper wire, control wiring with 1.5 sq. mm PVC insulated copper conductor cable, cable alleys, cable gland plates etc including following switch gears and preparation of SLD drawing with class B contractor certification for the complete work for approval from KEI including digital copy in CAD file.(LT Main Panel ) (I) Incoming-KSEB a) 630 Amp 4 pole MCCB, @ 415V and 36 kA, with microprocessor release, extended rotary operating handle, Spreader Terminal, Ics=100% Icu -1 No b) LED indicating light with MCB’s and control wiring for RYB indication - 1 set e) 600/5 A CT with 15 VA burden, accuracy class 1 -1 set f) digital type multi-function meter - 1 set (II) Incoming -Solar a) 630 Amp 4 pole MCCB, @ 415V, 36 kA, with thermal magnetic release and rotary operating handle, Spreader Terminal, Ics=100% Icu. - 1Nos. (III) Outgoings a) 250 Amp 4 pole MCCB, @ 415V, 25 kA, with thermal magnetic release and rotary operating handle, Spreader Terminal, Ics=100% Icu. - 4Nos. b) 160 Amp 4 pole MCCB, @ 415V, 25 kA, with thermal magnetic release and rotary operating handle, Spreader Terminal, Ics=100% Icu. - 2Nos. c) 125 Amp 4 pole MCCB, @ 415V, 25 kA, with thermal magnetic release and rotary operating handle, Spreader Terminal, Ics=100% Icu. - 4 Nos. (Note: All MCCB's shall be with spreader terminal) |
| 50 | Supplying installation, testing and commissioning of free-standing indoor compartmentalized cubicle type panel suitable for 415 V, 3phase, 4 wire 50Hz AC supply system fabricated in CRCA sheet steel of 14-gauge thick, detachable gland plates of suitable size at the bottom for cable entry, and busbar chamber with tinned copper bus bar of 250A capacity, handle, gaskets etc. including powder coat painting in approved shade, ISMC channel at bottom, entire panel shall have a common tinned copper earth bar of size 20 mm x 3mm at the rear with 2 nos earth stud, solid connections from switch gears with required size of copper wire, control wiring with 1.5 sq. mm PVC insulated copper conductor cable, cable alleys, cable gland plates etc including following switch gears. (LT Sub Panel ) a) 250 Amp 4 pole MCCB, @ 415V and 36 kA, with thermal magnetic release, extended rotary operating handle, Spreader Terminal, Ics=100% Icu -1 No b) LED indicating light with MCB’s and control wiring for RYB indication - 1 set e) 250/5 A CT with 15 VA burden, accuracy class 1 -1 set f) digital type multi-function meter - 1 set II. Outgoings a) 125 Amp 4 pole MCCB, @ 415V, 25 kA, with thermal magnetic release and rotary operating handle, Spreader Terminal, Ics=100% Icu. - 3Nos. c) 63 Amp 4 pole MCCB, @ 415V, 25 kA, with thermal magnetic release and rotary operating handle, Spreader Terminal, Ics=100% Icu. – 2 Nos. (Note: All MCCB's shall be with spreader terminal) |
| 51 | Labelling of DB/Main panel with Enamel paint/strong adhesive plastic coated label (3M make) (3 to 6 letters, maximum 25sq.cm. size) necessory arrangement for fixing on exixting DB/switch board etc. as required. |
| 52 | Supplying, Installation, Testing and Commissioning of cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 53 | Dismantling and removal of existing clamped electrical cable in wall, including removal of clamps, careful drawing out of cable without damaging wall finish, and handing over to the store/yard. |
| 54 | Rerouting of existing electrical cable in wall/ceiling/tray including dismantling from old route, removal of clamps if any, drawing along new route, fixing with clamps/saddles as required, making good wall/ceiling/tray surface, testing continuity & insulation and also careful drawing out of cable without damaging existing conduit/cable and wall finish etc as required. |
| 55 | Supplying and fixing cable identification tags made of aluminum sheet, minimum size 100 mm × 30 mm × 2 mm thick or nearst, duly engraved with cable number, voltage grade, feeder details, source and destination, and securely fixed to existing cables with stainless steel binding wire/SS cable ties at both ends, joints, bends, crossings and at intervals not exceeding 15 m in cable trenches, complete as required. |
| 56 | Electrical Works for relocation of UPS and Battery Rack in CNC |
| 57 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 58 | 20 mm |
| 59 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 60 | 3 x 1.5 sq. mm |
| 61 | 3 x 2.5 sq. mm |
| 62 | 3 x 4 sq. mm |
| 63 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 64 | 1 or 2 Module (75mmX75mm) |
| 65 | Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 66 | Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 67 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 68 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 69 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 70 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 71 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 72 | Supplying and providing \\" Excel \\" Earthing compoung including mixing with excavated fine soil and water to make it as slurry and filling around the earth plate etc. as required. |
| 73 | Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required |
| 74 | Supplying and laying 25 mm x 3 mm copper strip at 0.50 meter below ground / clamping on wall as strip earth electrode , including connection / terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) |
| 75 | Supply of 1.1 kV grade 3.5C x 185 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required. |
| 76 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 77 | 120 mm dia (00-120 mm & ID-103 mm nominal) |
| 78 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 79 | Above 95 sq. mm and upto 185 sq. mm |
| 80 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 81 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 82 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 83 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 84 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 85 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 86 | Supply of 1.1 kV grade 4C X 50 Sq.mm PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)1988 |
| 87 | Wiring of circuit/submain wiring along with earth wire with the 4 x 35 sq.mm +2x 10 sq.mm of FRLS PVC insulated copper conductor, single core cable in surface medium class PVC conduit/flexible etc as required. |
| 88 | Wiring of circuit/submain wiring along with earth wire with the 4 x 25 sq.mm +2x 10 sq.mm of FRLS PVC insulated copper conductor, single core cable in surface medium class PVC conduit/flexible etc as required. |
| 89 | Supplying and making end termination of PVC insulated copper conductor 4x35+ 2x10 sqmm submain wiring with suitable size Copper lugs etc as required. |
| 90 | Supplying and making end termination of PVC insulated copper conductor 4x25+ 2x10 sqmm submain wiring with suitable size Copper lugs etc as required. |
| 91 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5C X 185 sqmm PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1kV grade as required. |
| 92 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C X 50 sqmm PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1kV grade as required. |
| 93 | Supplying and fixing 3 phase 4 way double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB) |
| 94 | Supplying and fixing 125A, 16kA, 4 pole MCCB(Thermal magnetic O/L & S/C protection), 415 V, Moulded casing circuit breaker (MCCB) in the existing MCCB DB , complete with connections, testing and commissioning etc, as required. |
| 95 | Supplying and fixing 125 A, 25 kA DPX3 160, FP MCCB (Thermal magnetic : O/L & S/C protection ) in the existing MCCB enclosure/DB, complete with connections, testing and commissioning etc. as required.(legrand or its equivalennt) |
| 96 | Supplying and fixing MCCB Enclosure suitable for fixing upto 125 A MCCB complete with connections, testing and commissioning etc. as required. |
| 97 | Supply and fixing of 250 A,35 kA ,TPMCCB, with theromagnetic release and terminal spreadrs in existing cubicle panel board including drilling holesin cubicle panel,copper busbars for connectrions, minor panel door/cubicle fabrication works etc as required (Site visit recomended) |
| 98 | Fabrication,Supply,conveyance,Installation,testing and commissioning of cubicle type dust and vermin proof,floor mounted made from 75x40x6 size C channel,front operated,Indoor panel board made out of 14SWG CRCA sheet with protection as per standard,concealed hinges,Neoprint Gasket, panel lock etc.Entire sheet work will be treated under seven tank process and the powder coated with siemens grey mat finish (copper Busbar and Earthing)Incomer: 250A 4P 25 kA Thermal magnetic based MCCB -2 Nos250A 4P Changeover switch - 1 NoOut going : 125A FP 25KA Thermal Magentic based MCCB - 4 NosMetering and Indication:RYB Indicators with control MCB-2 setsMulfifunction meter for incomers with CT - 2 Nos ( Contractor should submit CT tested certificates approved by the competent authority according to the recent regulatory norms) |
| 99 | Supplying and fixing the identification details of cables and Distribution boards details with Enamel paint/vinyl stickers (3M make) on existing 4 nos of DB etc. as required. |
| 100 | Supply and fixing of 63A rating 415V, c curve miniature circuit breaker suitable for inductive load for triple pole in the existing MCB DB complete with connections testing and commissioning etc as required |
| 101 | Charges for removing the existing UG cable from the wall including all accessories without making damages, making good the damages of the wall/ floor including painting as per the site condition and conveyance of the materials to the godown etc as required |
| 102 | Charges for removing the existing 2 nos of DB, (All, cable wires & PVC conduits) making good the damages of the wall / floor including painting other accessories without any damage and conveyance of the material to the godown etc, as required. |
| 103 | Proposal for Supply, Installation, Testing and Commissioning (SITC) of 2 Nos. 20 kVA Online UPS Systems at Pragati Bhavan including buy back. |
| 104 | Supply, Installation, Testing and Commissioning of 3 phase 20 kVA UPS and batterries.Detailed specification attached in Appendix-1. |
| 105 | Buy back value of 2 nos. Eaton make 15kVA online UPS- along with 48 nos. of 12V, 26Ah VRLA batteries. |
| 106 | Buy back value of 1 no. GE make 20kVA online UPS with 40 nos. of 12V, 17Ah VRLA batteries. |
| 107 | Part-B:Comprehensive Annual Maintenance Contract including spares and service and replacement of battery units per annum after guarantee and liability period as per terms and conditions specified in tender document at existing GST rate. |
| 108 | 1st Year CAMC charge for the 20kVA UPS |
| 109 | 2nd Year CAMC charge for the 20kVA UPS |
| 110 | 3rd Year CAMC charge for the 20kVA UPS Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender