Tender For Internal Electrification Of Level 6 Of Techno Park (Sh: Electrical Works)
Tender Value
99.98 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
0 days left
EMD
1.99 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal Electrification Of Level 6 Of Techno Park (Sh: Electrical Works)
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 6 x 1.5 sq. mm |
| 6 | 3 x 2.5 sq. mm |
| 7 | 6 x 2.5 sq. mm |
| 8 | 3 x 4 sq. mm |
| 9 | 6 x 4 sq. mm |
| 10 | 3 x 6 sq. mm |
| 11 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 20 mm |
| 13 | 25 mm |
| 14 | 32 mm |
| 15 | Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 16 | Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system. |
| 17 | End cap |
| 18 | Internal angles- adjustable from 80°-100° |
| 19 | External angles- adjustable from 60°-120° |
| 20 | Flat junction |
| 21 | Supply and fixing of 105 x 50 mm DLP trunking white-system but without cover and partition etc. as required complete. |
| 22 | Supply and fixing of following accessories suitable for 105 mm x 50 mm size plastic trunking white system. |
| 23 | 85 mm flexible cover |
| 24 | End cap |
| 25 | Internal angles- adjustable from 80°-100° |
| 26 | External angles- adjustable from 60°-120° |
| 27 | Flat junction |
| 28 | Flat angles |
| 29 | Separation partitions |
| 30 | Joints for 85mm width cover |
| 31 | Base joints |
| 32 | Clip-on partitions |
| 33 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 34 | 5/6 A switch |
| 35 | 15/16 A switch |
| 36 | 3 pin 5/6 A socket outlet |
| 37 | 6 pin 15/16 A socket outlet |
| 38 | Blanking Plate |
| 39 | Telephone socket outlet |
| 40 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 41 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 42 | 1 or 2 Module (75mmX75mm) |
| 43 | 3 Module (100mmX75mm) |
| 44 | 4 Module (125mmX75mm) |
| 45 | 6 Module (200mmX75mm) |
| 46 | 8 Module (125mmX125mm) |
| 47 | 12 Module (200mmX150mm) |
| 48 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 49 | 1 or 2 Module |
| 50 | 3 Module |
| 51 | 4 Module |
| 52 | 6 Module |
| 53 | 8 Module |
| 54 | 12 Module |
| 55 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 56 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 57 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 58 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 59 | Laying of one run of UTP cable enhanced cat 5/cat 6 cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept) |
| 60 | Supplying and fixing following modular switch/ socket on the existing clip-on frame fixed on 85mm cover of 105 x 50 mm DLP plastic trunking including connections etc. as required complete. |
| 61 | Information Socket - RJ45 -CAT 6 - UTP - tooless with shutter - 1 Module cat. 6792 65 Legrand make |
| 62 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 63 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 64 | 12 way , Double door |
| 65 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 66 | 6 way (4 + 18), Double door |
| 67 | 8 way (4 + 24), Double door |
| 68 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 69 | 8 way (4 + 24), Double door |
| 70 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 71 | Single pole 5 A to 32 A |
| 72 | Double pole 5 A to 32 A |
| 73 | Triple pole 5 A to 32 A |
| 74 | Triple pole and neutral 5 A to 32 A |
| 75 | Double Pole (40A-63A) |
| 76 | Triple pole (40A-63A) |
| 77 | Four Pole (40A-63A) |
| 78 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 79 | 100 A,30KA,FPMCCB |
| 80 | Supplying and laying of one no.following PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kV as required complete on surface/ tray with Ms clamps etc. |
| 81 | 3.5c x 70sq.mm. |
| 82 | 3.5c x 50sq.mm. |
| 83 | 3.5c x 35sq.mm. |
| 84 | 4 c x 16sq.mm. |
| 85 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 86 | 4 X 10 sq. mm (25mm) |
| 87 | 3½ X 35 sq. mm (32mm) |
| 88 | 3½ X 50 sq. mm (35mm) |
| 89 | 3½ X 70 sq. mm (38mm) |
| 90 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 91 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 92 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 93 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 94 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 95 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 96 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 97 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 98 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 99 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 100 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 101 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 102 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 103 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 104 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 105 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 106 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 107 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 108 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 109 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 110 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 111 | 600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 112 | 900 mm width X 62.5 mm depth X 2.0 mm thickness |
| 113 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 114 | 1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 115 | Supply, Installataion, Testing & Commissioning of LED fitting tube light with heat dissipation capability. Opaldiffuser creates optimum light uniformity with minimum glare. It has a system leve llumen out put not less than 2000 lumens with luminaire efficacy of notless than 100lm/W. constant current output driver, operating range 150–270VAC supply, voltages, LED Colour Temp. from 5700K - 6500K with PF≥0.95 and THD<10% & surge protection ≥2.5kv, CRI >80, lumen maintainence of 70% at the end of 50000 burning hours. The luminaire is IP20 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM80 for LED source issued by LED manufacturer. |
| 116 | Supply, Installataion, Testing & Commissioning of surface mounted round LED downlighter with powder coated die-cast aluminium housing and LEDs of approved make fixed on die cast housing and high efficiency diffuser. Specially designed flat opal diffuser fixed to housing with engg. Plastic front cover, Driver installed on cast aluminium housing or externally and prewired upto the terminal block. It has a system lumen not less than 1200 lumens with luminaire efficacy of not less than100lm/W and lumenmaintainence of 70% at the end of 50000 burning hours with constant current driver output, operating range 150V–270V, 50Hz AC supply, CCT of 5700K-6500K with PF≥0.95 and THD must be <10% & surge proctection of≥ 2.5kv. The luminaire is IP20 protected. LM79 report to be submitted forluminaire from NABL accrediated lab and LM80 for LED source issued by LEDmanufacture. LED shall have reversepolarity, open and short circuit protection. |
| 117 | Supply, istallataion, Testing & Commissioning of recessed type LED downlighter with powder coated die-cast aluminium housing and LEDs of approved make fixed on diecast housing and high efficiency diffuser. Specially designed flat opal diffuser fixed to housing with engg. Plastic front cover, Driver installed on cast aluminium housing or externally and prewired upto the terminal block. It has a system lumen output not less than 1200 lumens with luminair eefficacy of not less than 100 lm/W and lumen maintainence of 70% at the end of 50000 burning hours with constant current driver output, operating range 150V–270V, 50Hz AC supply, CCT of 5700K-6500K with PF≥0.95 and THD must be<10% & surge proctection o f≥2.5kv. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection. |
| 118 | Supply, installation, testing & commissioning of recessed type LED downlighter with powder coated die-cast aluminium housing and LEDs of approved make fixed on diecast housing and high efficiency diffuser. Specially designed flat opal diffuser fixed to housing with engg. Plastic front cover, Driver installed on cast aluminium housing or externally and prewired upto the terminal block. It has a system lumen output not less than 1800 lumens with luminair eefficacy of no tless than 100lm/W and lumen maintainence of 70% at the end of 50000 burning hours with constant current driver output, operating range 150V–270V, 50Hz AC supply, CCT of 5700K-6500K with PF≥0.95 and THD mustbe <10% & surge proctection of ≥2.5kv. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire from NABL accrediated laband LM 80 for LEDs our ceissued by LED manufacture. LEDs hall have revers epolarity, open and short circuit protection. |
| 119 | Supply, Installataion, Testing & Commissioning of LED fitting tube light with heat dissipation capability. Opal diffuser creates optimum light uniformity with minimum glare. It has a system level lumen output not less than 900 lumens with luminaire efficacy of not less than 100lm/W. constant current output driver, operating range 150–270V AC supply, voltages, LED Colour Temp. from 5700K-6500K with PF≥0.95 and THD<10% & surge protection ≥2.5kv, CRI>80, lumen maintainence of 70% attheend of 50000 burning hours. The luminaireis IP 20 protected. LM 79 repor t to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacturer. |
| 120 | Supply, Installataion, Testing & Commissioning of Recessed mounted LED 4ft linear LED luminaire delivering an initial system lumen of 3600 lumens & the luminaire shall be with system efficacy ≥100lm/W. The luminaire Housing shall be made of CRCA, Rim: Engineering plastic/ CRCA, Optics: polycarbonate/PMMA polysterene. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V, THD≤10% &PF≥0.95, 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 &L M80 is sued by LED manufacture along with Photo Biological Safety Standard. |
| 121 | Supply, Installataion, Testing & Commissioning of LED Bulkhead luminaire, Vandal resistant Polycarbonate diffuser with IP 65, IK08 dust tight and water Jet proof for clean operation, lumen maintaine nce of 70% at the end of 50000 burning hours, operatin grange 150–270V, 50Hz AC supply voltages and system lumen output not less than 800lm, luminaire efficiency of luminaire not less than 80lm/W, THD<10% & Surge protection ≥2.5kV, CCT 5700K-6500K. LED shall have reverse polarity, open and short circuit protection. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacturer. |
| 122 | Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 123 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 124 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 125 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. |
| 126 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 127 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 128 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 129 | Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. |
| 130 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 131 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 132 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 133 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 134 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 135 | Installation, testing and commissioning of 2mm thick cubical type floor mounted front accessible switchgear LT panel with FP aluminium bus bar as per following details and enclosed specifications. |
| 136 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 137 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 138 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 139 | Refixing of switch / socket /regulator I/c cleaning, connecting, commissioning etc as reqd. |
| 140 | Fixing of RJ-45 modular box with cover plate or I/o box for internet on surface/ recessed cutting the wall making good the same as required. ( box and cover plate will be supplied by dept.) |
| 141 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 142 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender