Tender For Repair And Replacement Of Existing Switchgears At Bn Hq And Cobs Of 15 Assam Rifles.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Jul 2026
6 days left
EMD
10000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Wokha → Nagaland
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Replacement Of Existing Switchgears At Bn Hq And Cobs Of 15 Assam Rifles.
BOQ
| Sl. No. | Item Description |
| 1 | REPAIR WORK |
| 2 | Dismantling of main switches, Change over sitiches and MCBs for old UNSV Panel Board including necessary connected works etc removed items will be the property of contractor which he will pay credit to the department. (Main Switch -1 Nos, Change over Switch -07 Nos and MCB - 21 Nos) |
| 3 | Supply, Installation, Testing and commissioning of Incomming Module for 01x500 KVA Transformer (Main Power Supply)CHANGEOVER SYSTEM make L&K(a) 800 Amps on load changeover between transformer DG1,DG2&DG3(b) PVC Multistrand copper wire 70 sqmm size 15.0m long (c) Copperlugs suitable for 70sqmm size cables |
| 4 | Supply, Installation, Testing and commissioning of DOL starter suitable for 10HP pump sets make L&K incl taking out old wornout Starter and making good the connections |
| 5 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Set |
| 6 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 7 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 8 | Supply& fixig HT 11 KV, outdoor type gang operated air break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 400 Amps. |
| 9 | Supplying and fixing PVC cables aluminum conductor twin core 2.50sqmm size |
| 10 | Supplying and fixing PVC cables aluminum conductor twin core 4.00sqmm size |
| 11 | Supplying and fixing PVC cables aluminum conductor twin core 10.00sqmm size |
| 12 | Supplying and fixing PVC gloves 8\\" dia with brackets and holders |
| 13 | Supplying and fixing PVC gloves 12\\" dia with brackets and holders |
| 14 | Supplying and fixing PVC gloves 8\\" dia with brackets and holders |
| 15 | Supply only insulation tape 5.0m long (Red/Green/Black - 30 Pcs each box) |
| 16 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour in two coats incl Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.using Berger/Asian paints,ICI paints |
| 17 | Finishing walls with Acrylic Smooth exterior paint of required shade : on Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface incl removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 19 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, allcomplete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) |
| 20 | Providing and fixing brass/CP bib cock of approved quality :15 mm nominal bore |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes |
| 22 | Providing and fixing health faucets Chromium plated :15 mm nominal bore make Jaquar Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender