Tender for Arm Of Ctf(Fhq) Buildings At Nsg C Us Manesar For The Year 2026-27(Sh: Civil & Elect Maintenance)

BOQ

Name of Work:- ARM of CTF(FHQ) Buildings at NSG C us Manesar for the year 2026-27(SH: Civil & Elect Maintenance)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2All kinds of soil.
3Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth
51:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
61:5:10 (1 cement: 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
7Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
8Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
9Centering and shuttering including strutting, propping etc. and removal of form for
10Shelves (Cast in situ)
11Edges of slabs and breaks in floors and walls
12Under 20 cm wide
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
14Thermo-Mechanically Treated bars of grade Fe-500D or more.
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
16Cement mortar 1:6(1 cement :6 coarse sand)
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
18Cement mortar 1:6(1 cement : 6 coarse sand)
19Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :
20cement mortar 1:4(1 cement :4 coarse sand)
21Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
22Cement mortar 1:4(1 cement :4 coarse sand)
23Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
24Granite stone slab of colour black, Cherry/Ruby red
25Area of slab upto 0.50 sqnn
26Area of slab over 0.50 sqm
27Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
28Granite work
29Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
30Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
31250x16 mm
32Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
33250x10 mm
34100x10 mm
35Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
36125 mm
37Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
38Providing and fixing to existing door frames.
3930 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856, complete as per direction of Engineer-in-charge.
40Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
41With 12 mm mild steel U beading
42Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
43Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
4425 mm thick
45Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
46Glazed Vitrified tiles Matt/Antiskid finish of size
47Size of Tile 600 x 600 mm
48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
4975 mm diameter
50110 mm diameter
51Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
52Single tee with door
53110x110x110 mm
54Single tee without door
55110x110x110 mm
56Bend 87.5°
5775 mm bend
58110 mm bend
59Shoe (Plain)
60110 mm Shoe
61Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
6212 mm cement plaster of mix:
631:6 (1 cement: 6 coarse sand)
6415 mm cement plaster on rough side of single or half brick wall of mix:
651:6(1 cement: 6 coarse sand)
6615 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
67Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
68New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
69Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
70Two or more coats on new work
71Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
72Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour
73Old work (one or more coats)
74Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
75Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
76One or more coats on old work
77Finishing walls with Acrylic Smooth exterior paint of required shade:
78Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface
79Old work (One or more coat applied @0.90 Itr/10 sqm).
80Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm
81Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge.
82Orissa pattern W.C Pan of size 580x440 mm
83Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge.
84Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall
85Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
86Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
87Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
88In cement mortar
89Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
90Of area 3 sq. metres and below
91Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
92Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
93Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
94100 mm dia pipe
95Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
96Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
97W.C. pan with ISI marked white solid plastic seat and lid
98Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
99White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
100Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10110 litre capacity - White
102Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete :
103White solid plastic seat with lid
104Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
105Flexible pipe
10632 mm dia
107Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
108Providing and fixing toilet paper holder :
109C.P. brass
110Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
111600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
112Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
11320 mm nominal dia Pipes
114Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall
11520 mm dia nominal bore
116Providing and fixing brass stop cock of approved quality :
11715 mm nominal bore
118Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
11925 mm nominal bore
12020 mm nominal bore
12132 mm nominal bore.
122Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
12315 mm nominal bore
124Providing and fixing uplasticised PVC connection pipe with brass unions :
12545 cm length
12615 mm nominal bore
127Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
128Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
12915 mm nominal bore
130Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
13115 mm nominal bore
132Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
13315 mm nominal bore
134Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
13515 mm nominal bore
136Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.
137Providing and fixing PTMT grating of approved quality and colour.
138Circular type
139125 mm nominal dia with 25 mm waste hole
140Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
14125 mm nominal bore, 152 mm long, weighing not less than 440 gms
142Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms.
143Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre:
144100 mm diameter C.I. pipe
145Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
146150 mm diameter
147Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
148150 mm diameter S.W. pipe
149Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
150100x100 mm size P type
151With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
152Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
153Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
154With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
155Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
156L D- 2.5
157Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
158For pipes 100 to 250 mm diameter
159Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) :
160Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5
161Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
162With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
163Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
164For fixed portion
165Powder coated aluminium (minimum thickness of powder coating 50 micron)
166For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
167Powder coated aluminium (minimum thickness of powder coating 50 micron)
168Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
169With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
170Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
171Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
172With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
173Rubbing and polishing of existing Kota stone slab flooring including jointed/filling of old flooring gap with grey cement slurry mixed with pigment to match the shade of the slab complete as per direction of Engineer in charge.
174Credit for MS section like angle, tee, flats, grill etc.
175Credit for SCI/CI pipe
176Deduct GST Factor on DSR-2023 Items @ 2.70% on total of DSR rates(i.e 1462654.00 x 2.70) = (-) 39,491.65(Variation Amt)
177Add for Cost index on DSR 2023 @ 4.03% on 1423162.34 =57,353.44
178Electrical
179Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable etc. as required.
180Group A
181Group B
182Group C
183Wiring for light/ power plug with 2X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable for loop earthing as required.
184Wiring for light/ power plug with 4X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable for loop earthing as required.
185Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1862 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1872 X 4 sq. mm + 1 X 4 sq. mm earth wire
1882 X 6 sq. mm + 1 X 6 sq. mm earth wire
1892 X 10 sq. mm + 1 X 6 sq. mm earth wire
1904 X 4 sq. mm + 2 X 4 sq. mm earth wire
1914 X 6 sq. mm + 2 X 6 sq. mm earth wire
1924 X 10 sq. mm + 2 X 6 sq. mm earth wire
193Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
194Group A
195Group B
196Group C
197Supplying and drawing following size of FRLS/ HFFR PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required
1981 x 1.5 sq. mm
1992 x 1.5 sq. mm
2003 x 1.5 sq. mm
2014 x 1.5 sq. mm
2025 x 1.5 sq. mm
2036 x 1.5 sq. mm
2049 x 1.5 sq. mm
2051 x 4 sq. mm
2062 x 4 sq. mm
2073 x 4 sq. mm
2084 x 4 sq. mm
2096 x 4 sq. mm
2103 x 6 sq. mm
2112 x 10 sq. mm + 1 x 6 Sq.mm
212Supplying and drawing following pair 0.5 mm dia FRLS/ HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required
2131 Pair
214Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
215Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
21620 mm
21725 mm
21832 mm
21940 mm
22050 mm
221Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
2225/6 A switch
2232 way 5/6 A switch
22415/16 A switch
2253 pin 5/6 A socket outlet
2266 pin 15/16 A socket outlet
227Telephone socket outlet
228TV antenna socket outlet
229Bell push
23025 amp switch
231Computer Jack ( RJ 45) Cat6 (1 module)
23216A, 240 V, , \\"C\\" curve, SP modular MCB
233Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
234Supplying and fixing two module stepped type electronic non modular piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required.
235Supplying and fixing one module stepped type electronic non modular piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required.
236Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
237Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
2381 or 2 Module (75mmX75mm)
2393 Module (100mmX75mm)
2404 Module (125mmX75mm
2416 Module (200mmX75mm)
2428 Module (125mmX125mm)
24312 Module (200mmX150mm)
244Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
2451 or 2 Module
2463 Module
2474 Module
2486 Module
2498 Module
25012 Module
251Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
252Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
253Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
254Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required.
255Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
2561 run of cable
257Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy identification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc.complete as required.
2581 run of cable
2592 Run of cable
260Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required.
261Group A
262Group B
263Group C
264Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
265Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
266Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 16 A modular socket outlet and 16 A/25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
267Supplying and fixing PVC batten/ angle holder including connections etc. as required.
268Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2698 way , Double door
27012 way , Double door
27116 way, Double door
272Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2736 way (8 + 18), Double door
274Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
275Single pole
276Double pole
277Triple pole and neutral
278Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
279Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
280Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
281Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
282Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
283Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75°C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
2841200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
285Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge
286Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required.
287Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required. ( Havells FLORETINE WL 1 LS or similar in Wipro/Philips/Jaquar/LT as approved by the Engineer -in- charge)
288Supply and installation of 400 mm sweep, 220 V, wall mounted fan along with speed regulator unit for speed control, on the existing wall, including connection, testing, commissioning etc. as required. (Make: Crompton/Havells/Orient/Usha/Bajaj/Almonard)
289Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required.
290Supply and installation of 150 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 270 CMH and a power consumption not exceeding 28 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard)
291Supply and installation of 200 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 500 CMH and a power consumption not exceeding 30 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard)
292Supply and installation of 250 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 750 CMH and a power consumption not exceeding 40 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard)
293Supplying and installation of 300 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)
294Supplying and installation of 450 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)
295Supplying and installation of 225/ 230 mm sweep, single phase, metallic exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Havells Ventil Air or with similar specifications C&G / Orient / Usha / Almonard)
296Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 160 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge.
297Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge.
298150 mm sweep.
299200 mm sweep.
300225 mm/ 230 mm sweep.
301250 mm sweep.
302450 mm sweep.
303Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc., complete as per the direction of the engineer-in-charge.
304Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required.
305Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F. ≥ 0.95, IP20, CRI ≥ 80 , Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
306Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
30718- 22 watt
30840 watt
309Supply, installation, testing, and commissioning of integrated LED Batten luminaire, with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
310Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required
311Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) ≤ 19 Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
312Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.
3135 - 7 watt
31412 - 15 watt
315Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard..
316Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm)
317CRCA Sheet Body (Thickness ≥ 0.50 mm)
31836 watt
319Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required.
320300 mm
321380 mm
322450 mm
323Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required.
324Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required.
325Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
32640/63 A Double pole
327Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32840/63 A Triple pole and neutral
329Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd i) 20 mm
330Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd i) 25 mm
331Supplying and fixing of 23 mm x 1.5 mm S.S./G.I. saddles on the following sizes of existing PVC or steel conduit, cable, pipe, etc., as required (Astral, Prayag, Ashirvad, Finolex, or as approved by the engineer-in-charge)i) 50 mm
332Rewinding of following size ceiling fan / exhaust fan/ Wall fan motor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted.
3331200mm Sweep ceiling fan
3341400mm Sweep ceiling fan
335Wall Fan upto 400 mm
336Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor).
337300mm / 380 mm exhaust fan
338450 mm exhaust fan
339600mm exhaust fan
340Providing and replacing ball bearing in following size ceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required. (Scrap material will be retained by the contractor). (Both side shield ball bearing of SKF/ NBC /TATA )
3411200mm Sweep ceiling fan.
3421400mm Sweep ceiling fan.
343300mm/ 380 mm exhaust fan
344450 mm exhaust fan.
345600 mm exhaust fan.
346Providing and replacing 2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).
347Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).
348Reconditioning of the oversized bush /bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor.
349Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor.
350Providing and fixing PVC clamp with connector for the ceiling fan capacitor in the existing ceiling fan, including connection, testing, etc., as required, including credit for the old PVC clamp, which will be retained by the contractor.
351Supplying, installation testing and commissioning of BEE 5 star rating, 25 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty)
352Supplying and fixing PRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required.
353Supplying and fixing suitable size GI/ PVC box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required.
354Providing and fixing Din-rail 35 mm on existing panel etc., as require
355Supplying and fixing 2 way, 60 Amp, two way connectors on the existing looping box / Panel board including connection etc as required.
356Supplying and fixing modular 20 A Motor starter on the existing modular plate switch box including connections but excluding modular plate etc. as required.
357Supplying and fixing Plug top following rating including connection etc. as required.
35816 A, three pin, Plug top ISI marked
3596 A, three pin, Plug top ISI marked
36025 A, three pin, Plug top ISI marked
361Supplying and fixing Bakelite Sheet of following size with screw in the existing looping box/ panel including cutting the sheet to required shape and size complete etc as reqd.
3626 mm thick
363Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
364Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)
365Supply, installation, testing and commissioning of 45 watts LED-based post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Cool White Or Warm White as per direction of Engineer-In-Charge.Make : RUBY (Clear) of Havells
366Providing and fixing fly proof stainless steel grade 304 wire gauge, to exhaust fan openings on the outer wall using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm, all complete with 2nd class teak wood beading 25X19 mm.
367Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required.
368Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store.
369Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required.
370Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store.
371Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
372Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
373Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required.
374Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits.
375Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56394091
AUTHORITY Government Departments
TENDER VALUE 19.80 Lakhs
LAST DATE 18-07-2026
Authority
Authority Name National Security Guard
Work Description Tender for Arm Of Ctf(Fhq) Buildings At Nsg C Us Manesar For The Year 2026-27(Sh: Civil & Elect Maintenance)
Basic Detail
Tender No 20/CS/2026-27/NSG
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 09 Jul 2026
Submission Date 18 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 19.80 Lakhs
Tender Fee Ref. Documents
EMD 39608
Exemption Not Available
Document List
5864528b-995d-4777-bfe0-dc2cf5bc6d48.html
BOQ_963436.xls
Tendernotice_1.pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

5864528b-995d-4777-bfe0-dc2cf5bc6d48.html

xls

BOQ_963436.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders