Tender For Repair Of Road Side Footpath, Shoulders, Hardstanding, Storm Water Drain, Sewage Network At Morabadi And Gr Area And Repair Of Damaged Mccb, Mcb, Db Electric Geyser, Ceiling Fan, Exhaust Fan At Khojatoli And Repair Of Street Light, Securit
Tender Overview
Project Description
Tender for Repair Of Road Side Footpath, Shoulders, Hardstanding, Storm Water Drain, Sewage Network At Morabadi And Gr Area And Repair Of Damaged Mccb, Mcb, Db Electric Geyser, Ceiling Fan, Exhaust Fan At Khojatoli And Repair Of Street Light, Security Light At Mh Area Under Ge Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thick (below or above ground level). |
| 2 | Demolition of Stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. |
| 3 | M&L for 75mm thick PCC type D2, 1:4:8 (using 40mm graded stone agg) as in sub base floor surface complete. |
| 4 | M&L for Sand filling under floors or in foundation including watering and consolidation for laying interlocking tiles complete all as specified and directed. |
| 5 | M& L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment in paths and hardstanding laid tightly over dry sand cushion (compacted) and joint filled with dry sand(colour and pattern as approved by GE) complete all as specified and directed.(Note: Sand will be measured and paid separatly). |
| 6 | M& L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment in paths and hardstanding laid tightly over dry sand cushion (compacted) and joint filled with dry sand(colour and pattern as approved by GE) complete all as specified and directed.(Note: Sand will be measured and paid separatly). |
| 7 | Description all as per ser item No 6 above but except interlocking tile. |
| 8 | M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over 20 mm thick screed bed or bedding in CM 1 : 6 complete all as specified. |
| 9 | Demolition of brick wk masonry built in cement mortar incl all quoins arches pillars etc |
| 10 | M & L Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in CM 1:6 |
| 11 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1: 4. |
| 12 | M&L Providing, cement concrete type C1 1:3:6 (20 mm graded aggreate) as in kerbs etc complete all as specified |
| 13 | M&L Providing, cement concrete type B0 1:2:4 (12.5 mm graded aggreate) as in coping etc similar work complete. |
| 14 | M & L, 10mm thick rendering on fair faces of brick work/concrete surface in CM (1:4) surface finished fair & even complete. |
| 15 | S&F 110mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 16 | M&L Moorum/red bajri filling in floors or pavings, road collar and berms etc laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified. |
| 17 | M&L for providing 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finishes |
| 18 | M & L, 15mm thick rendering on fair faces of brick work/concrete surface in CM (1:6) surface finished fair & even complete. |
| 19 | M & L PCC 1 : 4 : 8 type D-2 using 40 mm stone aggregate as in foundation filling and mass concrete . |
| 20 | M&L for Plain cement Concrete C2,1:3:6 (40mm graded aggregate) as in surface channels and drains. |
| 21 | M & L PCC 1:2:4 type B-1 using 20 mm graded store aggregate as in coping including use and waste of form work where necessary. |
| 22 | M&L for extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra, including forms, moulds, mitred/ stopped end etc. |
| 23 | Exavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 Mtr in depth for foundation, disilting of drains etc n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose of soil. |
| 24 | Removing surplus soil to a distance n exc 50M and depositing where directed at a level not exc 1.5M above the starting point . |
| 25 | Demolition of cement concrete (reinforcement) any description and position not other wise specifically. |
| 26 | M&L for precast RCC 1:2:4 manhole cover extra set in cement mortar 1:6 |
| 27 | M & L Mild steel bars 10mm dia TMT Bars and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips. |
| 28 | M & L for Cleaning the blockage of sewage line, removing of any blockage in the pipe line by Mechanical means , roading or any other suitable means removing the accumulated Night Soil, Sludge and other materials obtained from sewage lines and disinfacted the sludge within 50 metres distance including necessary excavation of Pits & returning, filing in sprinkling of Bleaching powder @ 0.50 kg/Sqm and dressing of surplus Soil, ground to slope if required and well flushing the pipe with water complete all as specified and directed by Engr-in-Charge for 200 mm dia sewage line |
| 29 | Description all as per above ser No 28 but 150mm dia sewage line |
| 30 | M & L for cleaning of Manholes (as existing shape & size) of depth n.exc 1.0 Meter by pumping out the sewage water complete removing the sluge and other materials from Manholes by Mechanical means , roading or any other suitable means removing the accumulated Night Soil, Sludge and other materials obtained from sewage lines and disinfacted the sludge within 50 metres distance including necessary excavation of Pits & returning, filing in sprinkling of Bleaching powder @ 0.50 kg/Sqm and dressing of surplus Soil, ground to slope if required and well flushing the manholes with water complete all as specified and directed by Engr-in-Charge |
| 31 | M & L for cleaning of Manholes (as existing shape & size) of depth exc 1.0 Meter but n.exc 2.00 Meter by pumping out the sewage water complete removing the sluge and other materials from Manholes by Mechanical means , roading or any other suitable means removing the accumulated Night Soil, Sludge and other materials obtained from sewage lines and disinfacted the sludge within 50 metres distance including necessary excavation of Pits & returning, filing in sprinkling of Bleaching powder @ 0.50 kg/Sqm and dressing of surplus Soil, ground to slope if required and well flushing the manholes with water complete all as specified and directed by Engr-in-Charge |
| 32 | Dewatring /Desludging of septic tank/soak well /soak pit and Manhole by manually or mechanically and removing muddy soil sludge etc . The removal of sludge to a distance not exceeding 250 metre and burried in the same pit. |
| 33 | Taking down carefully exising unserviceable copper/aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 34 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 35 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 36 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSHH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSHH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(Contractor should make good even distributed wall/surface as before.) |
| 37 | (a) One light point controlled by one, one way switch 5 Amps |
| 38 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 39 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 40 | (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 41 | Description all as per above ser item No 36 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 42 | S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 43 | S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified. |
| 44 | S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified |
| 45 | S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified. |
| 46 | S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified. |
| 47 | S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked |
| 48 | S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed |
| 49 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 50 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSHH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 51 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 52 | S & F for sheet metal enclosure MCB DB VTPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 53 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 54 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 55 | S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified. |
| 56 | S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 57 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 58 | S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 59 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 60 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender