Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56393977

Tender For Repair/ Maintenance/ Renewal Of Point Wiring, Submain Wiring And Light Fitting Fixture & Connected Items For Tech Area/Otm Buildings At Af Stn Udh Ur

Issued by Statutory Bodies & Commissions/Committees · Udhampur, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Jul 2026
9 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance/ Renewal Of Point Wiring, Submain Wiring And Light Fitting Fixture & Connected Items For Tech Area/Otm Buildings At Af Stn Udh Ur

BOQ

Name of Work:- REPAIR/ MAINTENANCE/ RENEWAL OF POINT WIRING, SUBMAIN WIRING AND LIGHT FITTING FIXTURE & CONNECTED ITEMS FOR TECH AREA/OTM BUILDINGS AT AF STN UDH UR
Sl. No. Item Description
1M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
2One light/Fan/Exhaust fan/bell point controlled by one switch complete all as specified and directed
3One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed
4One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed
5M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core in existing concealed conduit & pressed steel concealed Sunken boxes not less than and new top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
6One light/Fan/Exhaust fan/bell point controlled by one switch complete all as specified and directed
7One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed
8One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed
9M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core in existing surface conduit & pressed steel concealed Sunken boxes not less than and new top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
10One light/Fan/Exhaust fan/bell point controlled by one switch complete all as specified and directed
11One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed
12One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed
13S&F Bell switch AC, 230 Volt single pole complete all as specified and directed
14S&F Bell AC, 230 Volt single pole complete all as specified and directed
15S&F switch piano, flush type, 5 amps single pole, one way complete all as specified and directed
16S&F socket 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed
17S&F socket 2 in 1, 3 pin, 5 Amps flush combination complete all as specified and directed
18S & F stepped type electronic fan regulator flush type complete all as specified and directed.
19S&F in repair ceiling rose 3 phase /PVC/polycarbonate,isolated body .
20M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with modular concealed box and modular outer and inner sheet suitable for Modular Switch & Socket painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI ]
21One light/Fan/Exhaust fan point controlled by one switch complete all as specified and directed
22One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed
23One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed
24M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core for point wiring in existing concealed conduit for Modular Switch & Socket with modular concealed box and modular outer and inner sheet, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
25One light/Fan/Exhaust fan/bell point controlled by one switch complete all as specified and directed
26One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed
27One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed
28M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core for point wiring in existing surface conduit for Modular Switch & Socket with modular concealed box and modular outer and inner sheet, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
29One light/Fan/Exhaust fan point controlled by one switch complete all as specified and directed
30One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed
31One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed
32S&F Modular Switch , 6 Amp, 1 pole one way complete all as speciified and directed.
33S&F Modular Socket, 2/3 pin, 6 Amp multipurpose complete all as speciified and directed.
34M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
35M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Existing Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
36M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
37M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
38M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Existing Conduit with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab Note on ser Item No 1-22 The rate will be inclusuve of suitable cover,and module frame for group of switches,sockets etc all as required as per site requirement.
39S&F modular switch , 16 Amp, single pole one way complete all as speciified and directed.
40S&F modular socket multipurpose 16 amps complete all as speciified and directed.
41Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete ,including fixture and fittings such as switches,ceiling roses,pendants ,reguators socket,light fitting etc removing materials to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions separtely) and making good disturbed surfaces of walls,floors etc.
42M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
43M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface existing conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 6.00 sqmm main cable and one RM of 6 .00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
44M&L Sub main wiring using approved colour coding as per IS with 4 single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid SurfacePVC conduit ISI Marked , heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: 4 runs each of 10.00 sqmm cable and one RM of 10.00sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
45S&F sheet steel powder coated distribution board SPN 4 ways, 220 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
46S&F sheet steel powder coated distribution board SPN 12 ways, 220 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB].
47S&F sheet steel powder coated distribution board SPN 8 ways, 220 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB].
48Supply and fix of polycarbonate/polystyrene 4 way distribution box, 400 V, IP - 66, ROHg complaint with clear/transparent cover neutral link, including provision for mounting MCBs complete all as specified and directed.
49Supply and fix of polycarbonate/polystyrene 8 way distribution box, 400 V, IP - 66, ROHg complaint with clear/transparent cover neutral link, including provision for mounting MCBs complete all as specified and directed.
50Supply and fix of polycarbonate/polystyrene 12 way distribution box, 400 V, IP - 66, ROHg complaint with clear/transparent cover neutral link, including provision for mounting MCBs complete all as specified and directed.
51M&L in repair of MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. .(Make: Indoasian or its equivalent/legrand /CG )
52M&L in repair MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. Make of Legrand or equavalent to HAVELLS / SIEMENS/indoasian
53M&L in repair MCB SP 32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. Make: of Legrand or equavalent to HAVELLS / SIEMENS/indoasian
54M&Lof MCB TPN 40-63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.(Make: Indoasian or its equivalent/legrand /CG )
55M&Lof MCB TPN 100 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.(Make: Indoasian or its equivalent/legrand /CG )
56S&F Recess mounting type fitting LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, Surge Protection>2 KV, IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. (Make Havells/Bajaj/CG or Equivalent.)
57Supply and fix in repairs LED lights fitting Four feet 1 x 20 Watt LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.Make :Bajaj/wipro/Havells /Orient/philips
58Supply and fix in repairs LED lights fitting Four feet 1 x 30 Watt LED 6500K, white/offwhitw/warm yellow, 3 in 1 with toggle switch, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
59M&L in repair of Lamp holder, insulated body, cord grip pattern SP 230 volt, including taking down complete all as specified and as directed.
60Supply and fixing in repar of LED 9/ 10 watt Bulb threaded type warm complete all as speciefed and as directed.
61Supply and fixing in repar of LED light fitting Bulk Head type with high out put diffuser 20 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge Make Havells/philips/bajaj/wipro
62Supply and fixing in repar of LED light fitting 2 feet 10 watt 220 V AC decorative type with driver holder and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge Make Havells/philips/bajaj/wipro
63Supply and in repair round type light fitting 9/10 Watt 230 V AC outdoor type complete with driver, lamp fixing of wall,ceiling with impact and corrosion resistant as per existing model fitting complete all as specified and as directed.
64Supply and in repair round type light fitting 2/3 Watt 230 V AC outdoor type complete with driver, lamp fixing of wall,ceiling with impact and corrosion resistant as per existing model fitting complete all as specified and as directed.
65Supply and fixing plastic type clips/saddle of size 15/20/25 mm complete all as speciefed and as directed.
66S&F occupation motion sensors 360 0 ceilling/roof mounted presence detector with lux sensor & adjustable timer , 230 volt including fixing an ceiling and making necessary electrical connection to existing electrical circuit complete all as specified and directed.Make : Schneider cat No CSS54E_WE and L&T/ABB
67M&L in repair of VTPN Vertical three phase distribution board, VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 125 Amps and MCBs as outgoing complete all as specified and as directed .(Make: Indoasian or its equivalent/legrand /CG )
68Supply and fix in repairs of MCCB 3P 25 to 100 Amps /415Volts ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and as directed
69Supply and fix in repairs of MCCB 3P 160 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
70Supply and fix in repairs of MCCB 4P 63 Amps /415Volts ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and as directed
71Supply and fix in repairs of MCCB 4P 100 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
72Supply and fix in repairs of MCCB 4P 160 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
73Supply and fixing of PVC Casing caping 16/20 mm complete all as specifed and as directed
74Supply and fixing of PVC Flexible pipe 15/20 mm complete all as specifed and as directed
75Supply and laying Rigid steel conduit, welded including fixing arrangement with clamp. Saddls complete all as specified and directed.
76Supply and in repair of building security LED street light fitting 35 Watt 6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection including suitable size bricket,clamps,fastner etc complete all as specified and as directed.
77Supply and fix flame proof Industrial panel mounted plug socket suitable for IP 67 degree protection 32 Amps rating, 2P+E complete all as specified and directed.
78Supply and fix flame proof Industrial panel mounted plug socket suitable for IP 67 degree protection 32 Amps rating 3P+N+E complete all as specified and directed.
79S&F Industrial bell of size 12 inch and more indoor/outdoor type, 220 volt with steel housing fixing on wall/roof including necessary connection complete all as specified and directed
80Taking down unserviceble highway lights from the height of approx upto 25 Mtr from ground level including eletric connections and supply & fixing highway lights 200 Watt Energy saving environment friendly & robust/ High bay LED luminanire with high efficiency (200lm/W) IP 66 with toughened glass industrial applications, including necessary electric connection, removing of wire net / mesh and refixing of wire mesh/ net and making good condition complete all as specified and directed by Engr in Charge. Make : Wipro/ Philips/ Crompton/ Havells
81Taking down unserviceble highway lights from the height of approx upto 25 Mtr from ground level including eletric connections and supply & fixing highway lights 250 Watt Energy saving environment friendly & robust/ High bay LED luminanire with high efficiency (250lm/W) IP 66 with toughened glass industrial applications, including necessary electric connection, removing of wire net / mesh and refixing of wire mesh/ net and making good condition complete all as specified and directed by Engr in Charge. Make : Wipro/ Philips/ Crompton/ Havells
82Supply only PVC insulated and unsheathed copper wire of size 1.5 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed [ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr
83Supply only PVC insulated and unsheathed copper wire of size 2.5 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed. [ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr
84Supply only PVC insulated and unsheathed copper wire of size 4.00 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed.[ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr
85Supply only PVC insulated and unsheathed copper wire of size 10.00 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed. [ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr
86Supply only 15 Amps switch socket combination including Box complete all as specifed and as directd
87Supply only 5 Amps switch complete all as specifed and as directd
88Supply only 5 Amps socket complete all as specifed and as directd
89S&F Heavy duty BLDC Exhaust fan of size 200 mm sweep, single phase 230V AC, 1400 RPM plastic body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
90S&F Heavy duty BLDC Exhaust fan of size 250 mm sweep, single phase 230V AC, 1400 RPM plastic body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
91S&F Heavy duty BLDC Exhaust fan of size 250 mm sweep, single phase 230V AC, 1400 RPM metal body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
92S&F Heavy duty BLDC Exhaust fan of size 300 mm sweep, single phase 230V AC, 1400 RPM metal body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
93M&L in repair of single pole and earth encloser with three pin and earth plug plus neutral with socket 32/40 Amps 240Volts complete indrustial type with Tripple pole MCB complete all as specified and directed
94M&L in repair of tripple pole and earth encloser with three pin and earth plug plus neutral with socket 63 Amps 415 Volts complete indrustial type with Tripple pole MCB complete all as specified and directed
95Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 25 sqmm 3.5/4 core laind in trenches or passing through pips/ ducts including taking down complete all as specified and directed by Engineer in charge
96Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 16 sqmm 4 core laind in trenches or passing through pips/ ducts including taking down complete all as specified and directed by Engineer in charge
97Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 10 sqmm 4.0 core laind in trenches or passing through pips/ ducts including taking down complete all as specified and directed by Engineer in charge
98Earthing complete with Galvanished steel earth plate electrode of size 60 cm X 60 cm X 6 mm thick as earth burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the earth plate not less than 1.5 Mtr below ground level using GI earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means thimbles, nuts, bolts, washers incuding jointing of earth electrode and eart wire by means of welding, all as directed including providing earth wire protection pipe GI light grade 20mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2mm thick duly fixed to angle iron frame with hinges of appropirate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil, removing surplus excavated material all as required at site and as specified in EP No. 3 of MES SSR Part-I (2009) directed by Engineer-in Charge including testing on completion.
99S&F of Earth continuity conductro 4mm Galvanised iron wire fixed to wall on battenor recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. Complete all as specified and as directed.
100Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified.
101Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
102Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
103M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge.
104M&L Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
105Supply and fix perforated MS/ GI cable tray minimum 100mm width and minimum 2.00 thick complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56393977
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance/ Renewal Of Point Wiring, Submain Wiring And Light Fitting Fixture & Connected Items For Tech Area/Otm Buildings At Af Stn Udh Ur
Basic Detail
Tender No GEAFU-46/2026-27
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 09 Jul 2026
Submission Date 21 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
6ba53147-b456-48a5-b415-c106b7393b02.html
BOQ_870749.xls
TEDNER46.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

6ba53147-b456-48a5-b415-c106b7393b02.html

xls

BOQ_870749.xls

pdf

TEDNER46.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender