Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56393972

Tender For Repair And Maintenance Of Building Internal Electrification Fittings/Fixture Along With Associated Items Under Dgnp Visakhapatnam.

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
20 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
9 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Building Internal Electrification Fittings/Fixture Along With Associated Items Under Dgnp Visakhapatnam.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF BUILDING INTERNAL ELECTRIFICATION FITTINGS/FIXTURE ALONG WITH ASSOCIATED ITEMS UNDER DGNP VISAKHAPATNAM.
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (S), DGNP (V) Name of Work: REPAIR AND MAINTENANCE OF BUILDING INTERNAL ELECTRIFICATION FITTINGS/FIXTURE ALONG WITH ASSOCIATED ITEMS UNDER DGNP VISAKHAPATNAM. Contract No: CA No. GE(S)/Token/ 01 of 2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only In order to arriving at net contract sum, amount of credit schedule shall be deducted from the total amount of this BOQ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl ITEM No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With all Taxes TOTAL AMOUNT With all Taxes TOTAL AMOUNT In Words
2Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors, etc.
3Taking down carefully sub main wiring 3 phases 5 wire with PVC conduit from exisitng position etc all as specified and directed
4Taking down carefully sub main wiring 1 phases 3 wire with PVC conduit from exisitng position etc all as specified and directed
5Material and labour for wiring light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insualted copper conductor single core cable etc. all as required and directed by Engineer-in-Charge
6All as per above item but with 1.5 sqmm for 5 Amp Socket outlet on independent boad with other accessories all as specified and directed
7All as per above item but with 2.5 sqmm for 5/15 Smp socket outlet all as specified and directed
8All as per above item but with 4sqmm for onw 3 pin socket oulter 15 Amps independent all as specified and directed
9All as per above item but drawn in casing caping with 1.5 sqmm for one ligh point controlled by two ways switch all als specified and directed
10All as per above item but drawn in casing caping with 2.5 sqmm for one 3 pin socket outlet 5 Amps independent all as specified and directed
11All as per above item but drawn in casing caping with 4 qmm for one 3 pin socket outlet, 5 Amps, independent, all as specified and directed
12Supplying and fixing 5A piano type switch/ socket on the exisiting switch box/ cover including connections etc. as required and directed by Engineer-in-Charge
13Supplying and fixing 16A piano type switch/ socket on the exisiting switch box/ cover including connections etc. as required and directed by Engineer-in-Charge
14Supply and fix Switch socket outlet 3 pin 5 amp' flush type all as specified and directed
15Supply and fix Switch socket outlet multi-purpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch all as specified and directed
16Supplying and fixing one way 6A modular 1 module switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc all as required and directed by engineer-in-charge.
17Supplying and fixing one way 16A modular 1 module switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc all as required and directed by engineer-in-charge.
18Supplying and fixing two way 6A modular 1 module switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc all as required and directed by engineer-in-charge.
19Supply and fix Socket 6A/16A - 2/3 pin combined 2 module all as specified and directed
20Supply and fix Bell push, flush type, 5 amp all as required and directed by engineer-in-charge.
21Supply and Fix single phase push button switch 240 Volts 50 Hz AC 25 Amp complete all as pecified and as directed by Engineer-in-Charge.
22Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete all as required and directed by engineer-in-charge.
23Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc all as required and directed by engineer-in-charge.
24Supply & fix surface mounted LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
25Supply & fix LED bulb 12 W,Bulb base B22,Lumens:1050lm,Cool day ligt,220-240 volts with connecting all accessories all as specified and directed
26Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
27S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
28Supply and fixingLED post top lentren light fitting outdoor type 20/25W incl taking down old one complete all as specified and directed by Engg-in-Charge.
29Supply and fixing LED 40 Watt round decorative post top lantern fitting with IP 65 protection incl taking down old one complete all as specified and directed
30Supply and fixing LED flood light 70/80 Watt die-cast aluminium IP 65 protection with high power LEDs as light source incl taking down old one complete all as specified and directed
31Supply and fixing LED security light 25/30 watt highly effective and efficient lighting with IP 65 protection with high power LEDs as light source with suitable size of light fitting incl bracket, clamps, nut bolts etc for fixing on wall/poles incl taking down old one complete all as specified and directed
32Supply and Fix LED light fitting of 30 Watt, 220 Volts AC surface mounted general purpose square shaped luminaire with low height CRCA housing and high transmissivity diffuser suitable for office application including connecting up with driver three core flexible copper conductor completed all as specified and as directed by Engr-in-Charge.Make: Phillips Cat No SM367 LED 30 56 500 G6 L54W54PSU OD
33Supply and Fix LED down lighten 15Watt round shape LED including connecting up with three core flexible copper conductor complete all as specified and as directed by Engineer-in-Charge.
34Supplying and fixing brass batten/ angle holder including connection etc all as required and directed by engineer-in-charge.
35Supply and fix PVC exhaust fan of 300 mm sweep, heavy duty 230 Volts, 50 Hz complete all as specified and directed. Deposit in MES store
36Supply and fix metal exhaust fan of 300 mm sweep, heavy duty 230 Volts, 50 Hz complete all as specified and directed.Deposit in MES store
37Supply, Installation, Testing and Commissioning of ceiling fan 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc complete all as required and directed by engineer-in-charge.
38Supply and fix fan capacitor 2.5mfd complete as specified and directed. by Engg-in-Charge.
39Supply and fix Fan step regulator, 120W - 2 module all as specified and directed
40M&L for wiring circuit/ submain wiring along with earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required and directed by Engr-in-Charge.
41M&L for wiring circuit/ submain wiring along with earth wire with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required and directed by Engr-in-Charge.
42Supply and fixing DB SPN 8 way double door including taking down complete all as specified and directed.
43Supply and fixing DB TPN 8 way vertical type double door complete all as specified and directed
44Supply and fixing DB SPN 4 way double door including taking down complete all as specified and directed.
45Supply and fixing MCCB TPN 100 Amp 16 KA including taking down complete all as specified and directed
46Supply and fixing Isolator DP 63 Amps, including taking down complete all as specified and directed
47Supply and fixing Isolator DP 40 Amps, including taking down complete all as specified and directed
48Supply and fixing MCB SP 6-32 Amps including taking down complete all as specified and directed
49M & L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
50M &L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only

AI Tender Summary

OUR REF NO 56393972
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Building Internal Electrification Fittings/Fixture Along With Associated Items Under Dgnp Visakhapatnam.
Basic Detail
Tender No GES TOKEN 01 OF 2026-27
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 09 Jul 2026
Submission Date 30 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
TNS1.pdf
73943d38-a6e4-459c-bd9b-2ae3d458afcf.html
BOQ_870620.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

TNS1.pdf

html

73943d38-a6e4-459c-bd9b-2ae3d458afcf.html

xls

BOQ_870620.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail