Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56393948

Tender For Repair / Replacement Of Internal Wiring, Electrical Fittings & Fixture, Renewal Of Bldg. Earthing And Other Connected Items & Repair / Replacement Ceiling Fans, Exhaust Fans, Geysers, Split / Window Type Air Conditioners, Water Coolers & D

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
36 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
20 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement Of Internal Wiring, Electrical Fittings & Fixture, Renewal Of Bldg. Earthing And Other Connected Items & Repair / Replacement Ceiling Fans, Exhaust Fans, Geysers, Split / Window Type Air Conditioners, Water Coolers & Deep Freezers, Solar Water Heater In repair of Of Otm / Md Accn At Dgqa Area And Navy At Hal Under Ge (North) Bangalore

BOQ

Name of Work:- REPAIR / REPLACEMENT OF INTERNAL WIRING, ELECTRICAL FITTINGS & FIXTURE, RENEWAL OF BLDG. EARTHING AND OTHER CONNECTED ITEMS & REPAIR / REPLACEMENT CEILING FANS, EXHAUST FANS, GEYSERS, SPLIT / WINDOW TYPE AIR CONDITIONERS, WATER COOLERS & DEEP FREEZERS, SOLAR WATER HEATER IN R/O OF OTM / MD ACCN AT DGQA AREA AND NAVY AT HAL UNDER GE (NORTH) BANGALORE
Sl. No. Item Description
1Taking down carefully aluminium/ copper wiring / power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets, light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
2Point wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch
3All as per item No. 2 above but forOne fan point controlled by one switch/regulator
4All as per item No. 2 above but forOne light point controlled by 2 way switch
5All as per item No. 2 above but forOne 3 pin socket out let 5 Amps on independent board
6All as per item No. 2 above but forOne bell / buzzer point controlled by bell push
7All as per item No. 2 above but forOne 3 pin socket out let 5 A on same board
8All as per item No. 2 above but for concealed wiring drawn through existing PVC conduit.One light point controlled by one switch
9All as per item No. 8 above but forOne fan / Exhaust point controlled by one switch / regulator
10All as per item No. 8 above but forOne light point controlled by 2 way switch
11All as per item No. 8 above but forOne 3 pin socket out let 5 Amps on independent board
12All as per item No. 8 above but forOne bell/buzzer point controlled by bell push
13All as per item No. 8 above but forOne 3 pin socket out let 5 A on same board
14Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
15Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick GI/MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
16All as per item No. 15 above but forOne fan point controlled by one switch / regulator
17All as per item No. 15 above but forOne light point controlled by 2 way switch
18All as per item No. 15 above but forOne 3 pin socket out let 5 Amps on independent board
19All as per item No. 15 above but forOne bell/buzzer point controlled by bell push
20All as per item No. 15 above but forOne 3 pin socket out let 5 A on same board
21Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
22Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 to 7 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be included in unit rate quated .
23M&L for groove cutting in wall/floor and making good of distrubed wall/floor, painting of existing colour all as specified and directed by Engineer -in-Charge.
24S&F in repair LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed.
25S&F in repair LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as specified and directed.
26S&F in repair 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed.
27S&F in repair 2' x 2' Surface mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed.
28Supply and fix in repair Slim surface mounted round LED down lighter of 12 watt aluminium die cast body with premium diffuser to ensure glare free & even distribution of light.
29Supply and Fix Modular switch 1 way 6A,1 module
30Supply and fix Modular switch 1 way 16A, 1 module
31Supply and fix Modular switch 2 way 6A,1 module
32Supply and Fix Modular Bell push 6A 1 module
33Supply and fix modular Socket, 6A - 2/3 pin combined 2 module
34Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module,
35Supply and fix modular type Fan step regulator, 120W - 2 module
36S&F of of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
37S&F of Angle holder PVC/polycarbonate type all as specified and as directed
38S&F of switch piano flush type single pole one way 5 Amps
39S&F of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed
40S&F of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
41S&F of bell push flush type 5A all as specified and as directed .
42S&F in repair of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed
43S&F in repair of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed
44S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
45S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed
46S&F in repair of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
47S&F in repair of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
48S&F in repair of MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
49S&F of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
50S&F of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
51S&F of Ding Dong bell AC 230 volts single pole.
52Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
53Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
54Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
55M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling and taking down old Earthing plates.
56Supply and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings.
57S&F in repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
58S&F in repair Bulk Head Fitting suitable for indoor application of 10 watt, including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed.
59S&F in repair Decorative wall light fixture made up of polycabonate suitable for indoor application of 9 watt LED lamp E27 blub holder , modern wall lamp( Metal black Up & down light) including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. Brand- BrightLyt
60S&F in repair LED Bulb suitable for indoor application of 9 watt, to fit in Angle Holder or Decorative wall light fixture all as directed. Make & Model No: Havells Cat part No: ADORE LED PLUS 9 W
61S&F in repair ceiling fans outer body with complete accessories, etc all as specified and as directed
62S&F in repair ceiling fans blade with complete accessories, etc all as specified and as directed
63S&F in repair ceiling fans internal body with winding complete accessories, etc all as specified and as directed
64S&F in repair PVC Fresh air fan MAXIMA DXI G02 IVORY DOM EX FAN of 150mm sweep 1200/1400 RPM with louver. Make Bajaj
65S&F in repair PVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 200/225mm sweep 1200/1400 RPM with louver. Make-Bajaj. or CG/Usha/ Orient/Phillips
66S&F in repair PVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 250/300mm sweep 1200/1400 RPM with louver. Make-Bajaj. or CG/Usha/ Orient/Phillips
67S&F in in repair replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps
68Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
69Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed.
70Supply only internal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed.
71Supply only heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed.
72Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
73Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
74Supply only Indicator lamp red and green type square/round.
75Supply only Safety valve/high pressure valve/NRV of exisitng type ISI marked.
76Supply only PVC insulated Copper cable flexible 3 core of size 40/0.0076 ISI marked.
77Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed.
78S&F in repair of exhaust fans outerframe for holding exhaust fan motor upto 225 mm sweep with supporting angle complete all as specified and directed.
79S&F in repair of exhaust fans outerframe for holding exhaust fan motor 300 mm sweep with supporting angle complete all as specified and directed.
80M&L in repair louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed
81S&F in repair of exhaust fans motor 300 mm sweep with supporting angle complete all as specified and directed.
82M&L in repair louver of exhaust fan suitable for 450 mm sweep complete accessories all as specified and directed
83M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No incluing taking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge.
84Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
85Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
86Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting/exhaust fan including greasing complete all as specified and as directed.
87Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
88Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
89Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
90PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed.
91Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
92Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its p complete all as specified and as directed.
93Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
94Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
95Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
96Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
97Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
98M&L extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
99Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M deep for laying cables and for foundation of poles etc and getting out in loose/soft soil.
100Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exceeding 25 cm complete using soil.
101Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
102M&L for sand cushioning with a layer of M sand 23 cm thick under and above the cable complete all as specified and as directed
103S&L sub class burnt bricks for cable protection complete as specified as directed
104S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches.
105S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core laid in trenches/wall.
106S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 4 core laid in trenches/wall.
107S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 4 core laid in trenches.
108S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trenches.
109S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trenches.
110S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
111S&F heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed.
112S&F heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
113S&F Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
114Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing and commissioning complete all as directed.
115Removing the split type AC of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directed for the following capacities:-1.5/2 ton capacityNote :- (i) Gas will be measured and paid separately item of this schedule.(ii) Spares cost more than 200 Rs will be measured and paid seperately under relevent item of this schedule.
116Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities:1.5/2Ton
117Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directd.
118Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for Split/window type AC 1.5/2 ton capacity.
119Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete all as directed.
120Removing the unservicable running capacitor of 40/80/100 MFD, Supply and fix of new capacitor suitable for 1.5/2 ton AC make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
121Removing the unservicable over load protection realay and Supply and fix new over load protector for split/window type AC of 1.5/2.0 TR capacity.
122Supply and fill refrigrent gas (R-22/410A/134A) for domestic cooling appliance.
123Disconnecting and taking out the unservicable sensor/remote unit completely and supply and fix new sensor unit of indoor unit of AC to suit the AC of Makes carrier/Bluestar/Voltas1.5/2 Ton Split type AC
124Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC any type and any make 1.5 Ton, 2 Ton capacity all as directed.
125Disconnecting and taking PCB circuit of disconnecting out PCB from split AC, repairing the same and refixing in original location complete all as specified and directed for 1.5/2 Ton capacity all as directed.
126Disconnect electrical connection, removing copper line, discharge line of split type AC upto 2 Ton capacity including indoor and out door units and all accessories and shifting/ reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
127Supply and fix plastic/coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unsv filter etc complete all as specified and as directed.
128S&F in replacement of brass angle valve for gas charging for split AC 1.5/2 ton of AC compete all as specified and as directed.
129S&F in replacement of swing motor of existing capacity and type for indoor unit of split AC fins complete all as specified and as directed
130S&F in replacement of MS fabrication clamps for hanging, fan including hook as existing complete all as specified and as directed
131S&F in replacement of Nitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed.
132S&F in replacement of Soft copper tubbing 15mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
133S&F in replacement of Soft copper tubbing 19mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
134S&F in replacement of Switch 32 Amps flush type with indication lamp all as specified and as directed
135S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 32 Amps flush type universal with indication lamp all as specified and as directed.
136Supply and fix voltage stabilizer suitable for Split/window type AC 1.5/2 Ton capacity complete all as specified and as directed. Suitable for Split/window type AC 1.5 Ton capacity
137suitable for Split/window type AC 2 Ton capacity
138S&F in repair hi wall split indoor units complete with 5 star rating and EER 3.2 of capacity 1.5 TON complete all as specified and as directed.
139S&F in repair hi wall split outdoor units complete with 5 star rating and EER 3.2 of capacity 1.5 TON complete all as specified and as directed.
140S&F in repair remort for suitable for Split / window type AC 1.5/2 Ton capacity complete all as specified and as directed.
141Removing the refrigretor of upto 320 ltr capacity from location servicing the refrigretor, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing and commissioning complete all as directed.
142Removing the refrigretor of upto 320 ltr capacity of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directed for the following capacities:-
143Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for refrigretor of upto 320 ltr capacity of any make including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities:
144Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of refrigretor of upto 320 ltr capacity and water coolers all as specified and directd.
145Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for refrigretor of upto 320 ltr capacity
146Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for refrigretor of upto 320 ltr capacity and testing complete all as directed.
147S&F in repair wall mounted busbar chamber 4 way with 200 A rated busbar for cable termination and end connection as specifide and as directed
148S&F in repair wall mounted busbar chamber 6 way with 200 A rated busbar for cable termination and end connection as specifide and as directed Please Enable Macros to View BoQ information
149S&F in repair wall mounted busbar chamber 6 way with 200 A rated busbar for cable termination and end connection as specifide and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56393948
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 31-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement Of Internal Wiring, Electrical Fittings & Fixture, Renewal Of Bldg. Earthing And Other Connected Items & Repair / Replacement Ceiling Fans, Exhaust Fans, Geysers, Split / Window Type Air Conditioners, Water Coolers & Deep Freezers, Solar Water Heater In repair of Of Otm / Md Accn At Dgqa Area And Navy At Hal Under Ge (North) Bangalore
Basic Detail
Tender No 8356
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 10 Jul 2026
Submission Date 31 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
414bd285-e48e-4971-b526-278365c560d1.html
8356Tender.pdf
BOQ_870887.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

414bd285-e48e-4971-b526-278365c560d1.html

pdf

8356Tender.pdf

xls

BOQ_870887.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender