Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56393938

Tender For Repair And Maintenance Of Internal Electrification, Cooling Appliances, Electric Supply Lt Cables, Lt Panels, Bollard Lighting, Street Light, Electric Poles, External Water Distribution Lines, Pump Motors & Dg Sets And Other Connected Work

Issued by Statutory Bodies & Commissions/Committees · Ganjam, Odisha
Tender Value
14.77 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
17 days left
EMD
29540
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Internal Electrification, Cooling Appliances, Electric Supply Lt Cables, Lt Panels, Bollard Lighting, Street Light, Electric Poles, External Water Distribution Lines, Pump Motors & Dg Sets And Other Connected Works At Cgra And Otm Gopalpur Under Ge (I)(Cg) Bhubaneswar

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, COOLING APPLIANCES, ELECTRIC SUPPLY LT CABLES, LT PANELS, BOLLARD LIGHTING, STREET LIGHT, ELECTRIC POLES, EXTERNAL WATER DISTRIBUTION LINES, PUMP MOTORS & DG SETS AND OTHER CONNECTED WORKS AT CGRA AND OTM GOPALPUR UNDER GE (I)(CG) BHUBANESWAR
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring including sunken MS boxes (light, fans, socket or power) complete, (fittings such as switches, ceiling roses,call bell, pendants, regulators, socket etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc complete all as specified & directed .
2M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified & directed .(Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Conduit :-Plaza/Prestoplast/Precision)
3M&L Point wiring for one light point or one fan point controlled by one switch with two runs of FRLS grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLS grade PVC insulated unsheathed stranded copper conductor for earth continuity wire to be drawn in and including PVC casing & caping ( medium grade) not less than 25 mm width with fittings & fixtures including MS sheet metal switch / terminal box 1.22 mm thick upto (200x300)mm size duly covered with backelite sheet cover 3.00mm thick and continutiy conductor shall be connected to common earth and earth dolly and making good disturbed surface to walls complete all as specified & directed . (Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
4All as per here and before item No-3 above but Concealed wiring in Existing Conduit .
5All as per here and before item No-3 above but for one light point controlled by one two way switch
6All as per item No. 3 above but for call bell point.
7All as per item No. 3 above but one 3 pin socket outlet 5 Amps on same board.
8All as per item No. 3 above but one 3 pin socket outlet 5 Amps but independent board with cable 1.5 Sqmm two run & 1.5 Sqmm one run of earth continuty.
9All as per item No.3 here in before but for 5/15 Amps point on independent board with two runs of 2.5 Sqmm FRLS grade PVC insulated unsheathed stranded Copper conductor and 2.5 Sqmm, FRLS grade PVC insulated, unsheathed, stranded copper conductor as earth wire.
10Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement.
11M&L Sub main wiring using two runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 1.5 Sqmm and one run of 1.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size and complete all as specified & directed .Note : Two runs of 1.5 Sqmm copper wire,one run of 1.5 Sqmm wire & one run PVC Conduit shall be measured as one unit.Make of wire: .(Make of wire: Finolex/Polycab/Plaza,Make of PVC Conduit:-Plaza/Prestoplast/Precision)
12M&L Sub main wiring using two runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size and complete all as specified & directed .Note : Two runs of 2.5 Sqmm copper wire,one run of 2.5 Sqmm wire & one run PVC Conduit shall be measured as one unit.Make of wire: .(Make of wire: Finolex/Polycab/Plaza,Make of PVC Conduit:-Plaza/Prestoplast/Precision)
13M&L Sub main wiring using two runs of FR grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size and complete all as specified & directed .ote : Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC Conduit shall be measured as one unit.Make of wire: .(Make of wire: Finolex/Polycab/Plaza , Make of PVC Conduit-Plaza/Prestoplast/Precision)
14Supply and fixing of Step type electronic Fan regulator flush switch type on the existing phonolic laminated sheet etc as required as existing type and size complete all as specified & directed .(Make-Anchor/Cona/Havells)
15Supply and fixing including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
16Supply and fixing including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
17Supply and fixing modular Bell push 6A 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
18Supply & fixing including connection modular socket outlet 2 /3 pin 6 Amps 2 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
19Supply & fixing including connection modular socket outlet 2 /3 pin 6/16 Amps 2 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
20Supply and fixing of Modular Fan regulator,120 watts complete all as specified & directed . (Make : .Crabtree/Cona/Havells)
21Supply and fixing of white modular cover plate with frame 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
22Supply and fixing of white modular cover plate with frame 2 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
23Supply and fixing of white modular cover plate with frame 3 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
24Supply and fixing of white modular cover plate with frame 4 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
25Supply and fixing of white modular cover plate with frame 6 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
26Supply and fixing of white modular cover plate with frame 8 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
27Supply and fixing of modular metal flush box 1/2 Module complete all as specified and directed.
28Supply and fixing of modular metal flush box 3 Module complete all as specified and directed.
29Supply and fixing of modular metal flush box 4 Module complete all as specified and directed.
30Supply and fixing of modular metal flush box 6 Module complete all as specified and directed.
31Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed mounted or surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified & directed .
32Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed .
33Supply and fixing round/square shape 12 watt 220 volts AC recessed or surface mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed .
34Taking down old Unserviceable DB including fittings/fixtures with MCBs of any make and size complete all as specified & directed.
35S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall,making good disturbed surfaces, complete all as specified & directed. (Make/Model :Cat No:DBSPN006DD of L&T or Standard/Legrand/HPL//Havells)
36Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with minimum service value 5.10 cubic meter/minute/watt. Five star rated with brushless direct current motor (BLDC) complete with remote control complete all as specified & directed.
37S&F in replacement Isolator, FP, 415 Volt 63 A TPN, of breaking capacity 35KA complete all as specified & directed. (Make L&T,Cat No.BF406300 or Standard/Legrand/HPL//Havells)
38All as per item No. 37 above but FP, 415 Volt 100 A TPN complete all as specified & directed.(Make L&T,Cat No.BF410000 or Standard/Legrand/HPL//Havells)
39S&F MCB, SPN. 6-32 Amps rating 240, volt, 'C' series, 10 kA complete all as specified & directed.(Make L&T,Cat No.BB20320D or Standard/Legrand/HPL//Havells)
40S&F MCB SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified & directed. ( Make L&T,Cat No.BB10320D or Standard/Legrand/HPL//Havells)
41S &F MCCB 4 pole (160-400)Amp ,415 Volt ,36 KA complete all as specified & directed. ( Make : C &S CSE2NN250ETM4P-250A or Standard/Legrand/HPL//Havells)
42S&F MCB DP, 40 Amps, 240 volt, 'C' Series, 10 kA ( Make L&T,Cat No.S&F MCB in replacement SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified & directed. ( Make L&T,Cat No.BB20400D or Standard/Legrand/HPL//Havells)
43S&F MCB DP, 32 Amps, 240 volt, 'C' Series, 10 kA ( Make L&T,Cat No.S&F MCB in replacement SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified & directed. ( Make L&T,Cat No.BB20320D or Standard/Legrand/HPL//Havells)
44Supply and fixing High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. ( Make /Model No :- CCS-100-20-65-HL2-DP-NWH(BRIGHT LINEA) of Crompton or equivalent of Phillips/Havells/ Bajaj/Wipro )
45Supply and fixing in repair sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) with taking down old U/S existing sheetmetal enclosure complete all as specified & directed. ( Make L&T/Legrand /Standard).
46Supply only PVC holder stand for capacitor of ceiling fan 1200mm sweep complete all as specified & directed.
47Supply only capacitor 230 Volts AC 50 HZ and rated capacity 2.5 MFD for ceiling fan complete all as specified & directed.
48Supply only capacitor 230 Volts AC 50 HZ and rated capacity 1.25 MFD for ceiling fan complete all as specified & directed.
49Supply only capacitor 230V AC 50 HZ and rated capacity 3.15 MFD for exhaust fan complete all as specified & directed.
50S&F PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm for ceiling fan complete all as specified & directed.
51S&F gun metal bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified & directed.
52S&F MS hook and clamps MS flat iron of existing size after taking out old rusted hook & clamp etc.for hanging/fixing of ceiling fan including cemented work complete all as specified & directed.
53S&F MS anodized bolts with anodized nuts, spring washers split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole for hanging of ceiling fan complete all as specified & directed.
54S&F in repairs down rod of suitable size including gromet/ reel type rubber pad with clamp & bolts, nuts and washers suitable for housing ceiling fan complete all as specified & directed.
55S&F in repairs louvers shutter made of MS sheet metal 1.2 mm thick for round base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 300 - 450 mm sweep complete all as specified & directed.
56S&F in repairs of PVC plug top of 5 Amps, 3 pin,230 volts complete all as specified & directed. (Make:Anchor/Cona/Roma)
57S&F in repairs of PVC plug top of 15 Amps, 3 pin,230 volts complete all as specified & directed. (Make:Anchor/Cona/Roma)
58S&F in repairs of Metallic plug top of 20 Amps, 3 pin,230 volts complete all as specified & directed. (Make:L&T/Havells/Cona/HPL)
59Supply and Replacement of Incoming cable with 3-core,PVC Stranded copper conductor of sizes 1.5 sq.mm with taking down of old unserviceable incoming cables complete all as specified & directed. Make- Polycab or equivalent of Richa/Mescab/Gloster
60S&F Modular switch 2 way 6A, 1 module complete all as specified & directed.
61S&F in replacement Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as specified & directed. Make:- Anchor/Cona/Havells
62S&F Switch piano, flush type, two pole, two way 5 Amps, 240V complete all as specified & directed. Make:- Anchor/Cona/Havells
63S&F Switch piano, flush type, single pole, one way 15 Amps, 240V complete all as specified & directed. Make:- Anchor/Cona/Havells
64S&F Bell push Switch, flush type, single pole, one way 5 Amps, 240V complete all as specified & directed. Make:- Anchor/Cona/Havells.
65S&F Call Bell ,Ding-Dong ,single pole, AC, 230 Volts complete all as specified & directed. Make:- Anchor/Cona/Havells.
66S&F in replacement Switch socket combination 2 in 1, 5 pin, 5 Amps flush type 240 Volt including box complete all as specified & directed. Make:- Anchor/ Cona/Havells.
67S&F Socket outlet 2 in 1, 5 pin, 5 Amps flush type 240 Volt complete all as specified & directed. Make:- Anchor/ Cona/Havells.
68S&F in replacement Socket outlet 2 in 1, 5 pin, 5/15 Amps flush type 240 Volt complete all as specified & directed. Make:- Anchor/ Cona/Havells.
69S&F in replacement Switch socket combination 5/15 Amps flush type,6 pin,5 in 1 complete all as specified & directed. Make:- Anchor/Cona/Havells
70S&F in replacement Ceiling rose,3 terminal PVC/poly carbonate isolated body complete all as specified & directed. Make:- Anchor / Cona/Havells.
71M&L for services of jointing/taping or checking the electrical connections and securing after defect rectification in existing points/connection/items for light/call bell/ fan/regulators/capacitor/ sockets/ switches/ceiling rose/ switch socket boards/ junction boxes /metal/MCB sockets/power sockets or connected circuits till MCB control in DB/earthing complete and refixing the existing items after defect rectification, as and when required/directed. Note: (i) Sufficient electrician /helper and other required items are to be provided immediately for repair as and when intimated (ii) The defect rectification of all connected items in the same circuits/ switch socket board will be counted as one job only (iii) Necessary tapping jointing lugging, minor connecting wires and securing and other minor items to make good the defects is deemed to be included complete all as specified & directed.
72Dismantling of Split type Air Conditioner, of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relays,PCB of indoor and outdoor units, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, complete all as specified & directed.
73Providing and refilling of refrigerant gas R-22/ R-32/ R-410A in split type air conditioners of any make, after carrying out necessary leak testing, vacumming of the system and ensuring proper pressure levels as per manufacturer's specifications. The work shall include checking for leakages, minor rectification (if required), and testing the unit for satisfatory performance after refilling, complete all as specified and directed.
74Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or taking up / down electrical cables / pipe. and getting out in soft/loose soil concrete complete all as specified & directed.
75Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified & directed.
76Removing excavated spoil to a distance n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified & directed.
77M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified & directed.Note- Punned thickness will be measured at the time of measurement and payment.
78S&F bricks fly ash bricks locally available of size 230mm x 115mm x 75mm best quality laid in trenches over sand cushioning for cable protection complete all as specified & directed.
79Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq mm 3.5 core, including taking down old UNSV cable complete all as specified & directed.
80S&F in replacement bracket for street light made out of 1.5 Mtr long, 40 mm bore GI tubing, medium grade bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size, including taking down old UNSV bracket complete all as specified and directed .
81Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells)
82Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells)
83Supply & fixing in repair Building security light fitting,new compact designed IP 66, Aluminium PDC housing with toughen glass cover high power LED street light/Building Security light of capacity 25 watt.including provn of necessary connection complete all as specified & directed. (Make/ Model:- Crompton(ASTRA NEO), Cat No . LSTS-25-CDL-M or equivalent make of Phillips/Havells/ Bajaj/Wipro)
84Supply and fixing in replacement inverted pyramid tripod type LED Bollard with soft 360 light distribution 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton CAT REF -LBLSN-10-CDL
85S&F, PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning complete all as specified & directed. Make: Plaza/ Gloster/Polycab.
86Supply and fixing in replacement of SMC junction box of size 270mm x 225 mm x 135 mm hinged type door 4 Nos terminal with 6-20 Amp MCB fixing on pole with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc including taking down old UNSV complete all as specified and directed. Make- Sintex or equivalent make approved by GE
87Labour for Repair/ maintenance of street lights/ yard lights/ high mast fitting/Bollard /garden luminaire of any size/ type fixed on poles/bldgs/tower including taking down as required at a height exc. 8m from the ground level including dismantling all the defective components, checking its serviceability circuit board, driver units and carried out necessary minor repairs/soldering of worn out circuits /connections, replacement of unserviceable parts and refixing the same after repair including connecting and testing the same, replacing the fused lamps, burnt out wiring, ballast and igniter, capacitor and reassembling and fixing the fitting to original position complete, testing and commissioningcomplete all as specified and directed .Note :(a) Replacement of fused wire is deemed to be included and other items will be measured and paid separately under relevant items, however securing wiring/ tapeing/refixing is deemed to be included in Job.(b) Irrespective of fittings/ components replaced, the measurement shall be made for one pole as one unit. (b) Attending through necessary ladder arrangement on vehicle or ladders etc shall be arranged by the contractor. (c) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (d) Contractor is completely responsible for the safety of manpower employed by him.
88Supply only the following for fixing the defective componets under relevant Item No 15 complete all as specified & directed.
89Supply only the following for fixing the defective componets under relevant Item No 15 complete all as specified & directed.
90(a) Driver unit suitable for LED street light fittings of 45/60 watts
91(b) MCPCB unit suitable for LED street light fittings of 45/60 watts
92(c) Surge protection suitable for LED street light fittings of 45/60 watts
93(d) Driver unit suitable for LED bollard light fittings of 10/12 watts
94(e) MCPCB unit suitable for LED bollard light fittings of 10/12 watts
95Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, meggering, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers as used will be paid separately. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (e) The fuse of call/breakdown and defect identification to be attended immediately within 2 hrs and process for proper defect identification should be completed in continuation alongwith any further workmen or equipment required as defect rectification being essential service in nature and the cost is deemed to be included in scope of work and also as directed. (f) Contractor is completely responsible for the safety of manpower employed by him.(g) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services.
96Dismantling and taking out old un-serviceable Non-integral light fittings from 16 mtr High mast tower with checking its connection and unserviceable parts ,such as Drivers,LED lamps ,LED Fittings etc and replace the same and refitting in its position including servicing the double drum winch and greasing the 5 mm dia steel wire rope, wheels,operating handles with all parts and equipments of existing High mast Tower ,fitting ,Allignment upto length, testing complete in all respect after the high mast tower mounted complete all as specified & directed. Note: The Lights fittings to be replaced shall be measured seperately under this schedule of item.
97S&F in replacement MCCB 4 pole with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps complete all as specified & directed. (Make: Legrand /Indoasian/Legrand/HPL//Havells)
98Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified & directed. ( Make : Legrand or equivalent in ABB/Schnieder)
99Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 36 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified & directed.( Make : Legrand or equivalent in ABB/Schnieder)
100M & L for cable fault finding of any size at any location complete with rectification duly joined by suitable jointing kit above 25 Sqmm cable complete all as specified & directed.
101S&F for replacement of on load change over switch with enclosure 3 phase 415 volt 50 Hz 160Amp to be fixed in existing panel complete all as specified & directed. Make L&T Type CO2-160 Cat No.C021600OOOO or equivalent in Indoasian/C&S
102S&F for replacement of on load change over switch with enclosure 3 phase 415 volt 50 Hz 63 Amp to be fixed in existing panel complete all as specified & directed. Make L&T Type CO1-63 Cat No.CO10630OOOD or equivalent in Indoasian/C&S
103Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends oredge steps, cills, sunshades, shelves, lintels,etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size complete all as specified & directed.
104Supply and fixing of neon light (RYB) complete on existing LT panel board including dismantling and taking out of old items complete with connected wiring for Phase indication complete all as specified & directed. ( Make : L & T or equivalent)
105Supply and fixing of Amperemeter digital (0-100)Amp, along with CT's complete on existing LT panel board including dismantling and taking out of old items complete all as specified & directed. ( Make : L & T or equivalent)
106Supply and fixing Voltmeter digital type with of (0-440) Volt on existing LT panel board including dismantling and taking out itms complete with connected wiring for Phase indication complete all as specified & directed. ( Make : Legrand or equivalent in ABB/Schnieder)
107M & L for Repair of air break gang operated switches vertical/horizontal type such as repair/ replacement of broken/worn out components & insulators and greasing the moveble parts ( Male/female parts) for smoth functioning complete all as specified & directed.
108S&F in replacrment of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV greasing the moveble parts ( Male female parts) for smoth functioning complete all as spcified and directed.
109Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified & directed.
110M & L for painting of two pole structure with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete all as specified & directed.
111M & L for painting of Street light pole with aluminium paint after removing old paint from steel pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete with numbering of pole complete all as specified & directed.
112Supply & fixing in replacement of breather Assembly for upto 250 KVA Transformer complete all as specified & directed. Make : MB Supplier/Pooja industries/Goyal electric works.
113S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 250 KVA Transformer complete all as specified & directed.
114Supply & fixing in replacement of breather Assembly for upto 200 KVA Transformer complete all as specified & directed.Make : MB Supplier/Pooja industries/Goyal electric works.
115S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 200 KVA Transformer complete all as specified & directed.
116Dismantling and taking down old un-serviceable all in one solar light fittings of any capacity and any make from existing pole and checking its connection and unserviceable parts ,such as lithium ferro phosphate battery, Charge controller, solar plate, Driver,LED and refitting after changing defective parts in its position including painting of solar light fitting and pole on which light is fitted with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint , testing complete in all respect after the refixing complete all as specified & directed. Note: The lithium ferro phosphate battery, Charge controller, solar plate, Driver,LED to be replaced shall be measured seperately under this schedule of item.
117Supply only the following for fixing the defective componets under relevant Item No 44 complete all as specified & directed.
118(a) Driver unit suitable for solar all in one LED street light fittings of 30/40 watts
119(b) Lithium ferro phosphate battery 12.8V , 36 Ah suitable for solar all in one LED street light fittings of 30/40 watts
120(c) Charge controller, 12V, 6A suitable for solar all in one LED street light fittings of 30/40 watts
121(d) LED Panel ( 140- 150 lumens / W) suitable for solar all in one LED street light fittings of 30/40 watts
122Disconnecting and removing existing unserviceable battery and S & F maintenance free battery 12 V 100AH with minium 2 years warrenty complete all as specified & directed. ( Make : Exide/Amco/Amaron)
123Disconnecting and removing existing unserviceable battery and S & F maintenance free battery 12 V 90AH with minium 2 years warrenty complete all as specified & directed. ( Make : Exide/Amco/Amron)
124M & L for replacement of battery lead set of 2 Nos 1.5m long copper lead of 35 Sqmm size including GM Materials at one end and copper lug at other and complete all as specified & directed.
125Material and labour for cutting the existing concrete/bituminous road surface width not exceeding 30cm and making good the surface with 100mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate finished even and fair complete over 75 mm thick PCC 1:4:8 type D2 using 40mm grade stone aggregate over consolidated/rammed earth surface complete all as specified & directed.
126S&F in Replacement of Galvanized Iron water tubing \\" Medium Grade\\" with all fittings laid/fixed in trenches/wall/ceiling or laid under floor etc for following sizes. The quted rate shall be inclusive of taking dow cost also, complete all as specified and directed.Make - Jindal/Tata or equivalent
12725 mm dia bore pipe
12840 mm bore pipe
12950 mm bore pipe
130Supply and fix CI sluice valve 100 mm dia flanged of class PN 1.6 conforming to IS - 14846 complete with iron wheel head , SS spindle and check nut , including jointing material such as rubber insertion nuts, bolts and washers etc complete all as specified & directed of following size : Make - Kirloskar/upadhaya/Leader/Zoloto or eqvlnt.
131Taking up & down,rethreading and refixing on existing Position of GI tube and connected fittings for the sizes of 25 mm to 80 mm and Supply only the following galvanised iron fittings ISI marked of following sizes of approved make complete all as specified and directed.
132GI UNION 25 MM
133GI UNION 40 MM
134GI UNION 50 MM
135GI SOCKET 25MM
136GI SOCKET 40 MM
137GI SOCKET 50 MM
138GI NIPPLE 25 MM
139GI TEE 25x25x25 mm
140GI TEE 40x40x25 mm
141GI Elbow 25mm
142GI Elbow 40x25mm
143GI NIPPLE 50 MM
144Supply and fix in replacement Gun metal globe or gate valve ISI marked high pressure with iron wheel head screwed both ends for iron pipe line and fixed properly for following sizes complete all as specified & directed. Make - Zoloto/Kartar/Lakshmi/Venus or equivalent.
14525 mm dia bore pipe
14640 mm dia bore pipe
14750 mm dia bore pipe
148Supply & Fix water flow meter Suitable for 100 mm dia Pipe line complete all as specified & directed.
149Supply and Fixing Pressure gauge 100 mm dia 0-14 kgs complete all as specified & directed.
150Suply only Crystal type white Amonia Alum Grade-1 quality suitable for water treatment plant complete all as specified & directed.
151Suply only chemicals soda Ash suitable for water treatment plant complete all as specified & directed.
152Suply only Sodium Hypochloride suitable for water treatment plant complete all as specified & directed.
153Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing etc for smooth running and replacement of packing gaskets, shaft sleeve, gland packing, neck ringnut bolts and washers etc, with necessary oiling and greassing of pump up to 10 HP complete all as specified & directed.
154Dismantling and taking down of motor from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,discconecting of electric connection from terminal loading/unloading the motor to vehicle and transportation of the motor to workshop, cutting the burnt winding and clean the rotor & stator with CTC or other cleaning matterial and rewinding of stator winding with supper enameled copper wire as per existing the size/gauge wire and turn of the previous winding, insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish . Afterward heating the stator in heat chamber for continous 2 days for better insulation resistance reassembling the stator & rotor carefully after replacement of worn out bearings, transportation of motor from workshop to its original location, unloading the motor and placing it on base frame, connection of motor with pump with tyre coupling and fixing to the base frame after checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load for continous running for 3 hrs of capacity up to 10 HP Induction motor complete all as specified and directed.
155M&L CI Foot Valve for suitable for 50 mm dia Tubing conforming to IS 4038 complete all as specified & directed.
156M&L for repair, cleaning and servicing of automatic star delta starter of capacity 10 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified & directed. (Note : Major defective parts will be measured and paid seperetely under relevent item as supply only)
157Cleaning and removing all scales and deposited materials in under ground water sump of capacity up to 2.5 lakhs ltr by drain out the ludge/wate at bottom of the tank by mannualy or using non cloging pump sets and applying bleaching powder , brushes for removing deposited materials and removal the same from sump and deposited the same where as directed (not more than 50 mtr) , including cleaning the sourrounding area of under ground sump complete all as specified & directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
158Cleaning and removing all scales and deposited materials in over head tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified & directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
159Disconnection of electric connection of 05 HP submercible pump from panel and remove GI pipe from bore well and taking out submersible pump and motor from bore well carefully & check the motor and carry the motor to work shop for repair. Then repair the motor including winding of the motor, Motor brush and key and clamp & nut and bolts etc. anf fixing 5 HP submersible pump and motor after repair inside the bore will carefully and fixing GI pipe 50 mm dia in same bore well and connect electric supply to motor and function satisfactory complete all as specified & directed.
160S&F in replacement rubber coupling F50 size to the pump motor shafts at pump house including connected nut bolts etc complete all as specified & directed.
161M&L for repair to RO Water purifier fully Automatic having cooling capacity 40/80 Ltr/Hr and other defective membrane parts and making good to function properly complete all as specified and directed.
162M&L for repair of RO water purifier circulating motor with suitable size /make complete all as specified and directed.
163S & F in replacement of RO water purifier connection pipe of size 1/4'' complete all as specified and directed.
164M & L for Servicing of DG set through authorised agency \\"B\\" check in replacement of fuel filter, primary and secondary, superbypass filter,oil filter. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling new engine oil complete for the following cpacity (a) :- Capacity 62.5 KVA & 40 KVANote:- (a) Engine oil will be measured and paid separately as supply only under respective items of schedule 'A'. (b) Air filter will be replaced in each servicing of DG Set as supply only under respective items of schedule 'A'.
165Supply only engine oil suitable for diesel generator set (Oil 15W/40) complete all as specified & directed. Make: Servo/ HP / Bharat Petroleum.
166Supply only coolant suitable for radiater of DG sets complete all as specified & directed. Make: HP/TVS/Servo
167S/F in replacement of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample) complete all as specified & directed.
168Supply only Air filter and air pre filter to DG set of following capacities: (a ) Capacity of DG Set 62.5 KVA & 40 KVA complete all as specified & directed.
169Supply only diesel filter to DG set of following capacities: (a ) Capacity of DG Set 200 KVA, 125KVA , 82.5 KVA ,62.5 KVA ,82.5 KVA
170Supply only Oil filter set (Lube oil filter+ O ring & by pass Lube oil filter+ O ring)(a ) Capacity of DG Set 200 KVA, 125KVA , 82.5 KVA ,62.5 KVA ,82.5 KVA
171M&L for repair of radiator including dismantling the radiator from DG set of any capacity after removing hose pipe connection, nut, bolts etc and taking out the same to civil workshop for repair and descaling of radiator using descaling chemical etc as approved to remove mud/deposit on fins and/in copper tubes including bracing of copper tubes for arresting of leakage and re-fixing after replacement of unserviceable hose pipes and clamps complete with testing for DG Capacity of 40-62.5 KVA complete all as specified & directed.
172M & L for repair of Self starter of 12/24 Volts by replacing unserviceable pinion/ armature/Field Coil/ Bushes/ Bearing/ Rivets etc all as required for smooth Functioning including testing and commissioning of 40 KVA,62.5 KVA complete all as specified and directed.
173M & L for repair of Dynamo of 12/24 Volts by replacing unserviceable Groove wheel/ armature including testing and commissioning of 40 KVA,62.5 KVA DG Set complete all as specified and directed.
174M&L for dismantling and taking out fuel injection pump for servicing from DG set of any type/make and capacity upto 62.5 KVA disconnection of fuel injector line, carrying complete overhauling/ servicing of injector pump, ,calibration of fuel pump as per manufacturer instruction , assembling the same with DG set properly in original postion, checking the allignment , making proper fuel connection and testing for smooth opreation complete all as specified & directed.
175Supply & fixing in replacement of old unservicable feed pump for fuel injection pump complete assy for DG upto 62.5 KVA complete all as specified & directed.
176M& L in repair opening / taking out of injector of DG set of any type/make and capacity upto 62.5 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreation complete all as specified & directed.
177Supply and fixing, in replacement, Radiator cap suitable for DG Set of any type / make and capacity, complete all as specified & directed.
178S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
179Supply and fixing, in replacement of Old unserviceable RPM CABLE of any size and length of existing complete all as specified & directed.
180S & F in replacement DG set Controller of capacity upto 62.5 KVA for automation operation of DG set compelete with connected acessories complete all as specified & directed.
181Supply and fixing, in replacement, of Electronic Automatic Voltage Regulator (AVR) suitable for DG Set of upto 62.5KVA capacity, with and including taking out old AVR and making all connection, testing for smooth operation complete all as specified & directed.
182Material & labour for carrying out complete overhauling / servicing of DG set panel/ control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as specified & directed.
183M & L for servicing of Governor of DG set of capacity 40 KVA complete with made functional including change of spare parts if required complete all as specified & directed.
184M & L for servicing of Governor of DG set of capacity 62.5 KVA complete with made functional including change of spare parts if required complete all as specified & directed.
185M & L for servicing of Water pump of DG set of any capacity upto 62.5 KVA complete with made functional including change of spare parts if required complete all as specified & directed.
186M&L for Reapirs to DG set door by welding and Brazing complete with locking arrangements complete all as specified & directed.
187Supply and fix DG set diesel tank cap with locking arrangements complete as per existing complete all as specified & directed.
188M &L for Cleaning diesel tank debris with draining out existing diesel from diesel tank completely all as specified & directed
189M&L for Servcing of DG set battery of 180 AH 12 V capacity by replacing distelled water and checking of specific gravity complete all as speicifed and directed
190Disconnecting and removing existing unserviciable battery & S& F maintenance free battery of 180 AH 12 V capacity with minimum 2 years guarantee complete all as specified & directed.
191M&L for Repair maintenance and servicing of Solar Water heater with checking and disconnecting its hot and cold water pipe lines connection and unserviceable parts ,such as heating chamber,pressure relif valve collecting pannel,hot water tank, water reservers and water make up tank etc and replace the minor spare parts and accessories including adequete/existing length and size inlet/outlet hot/cold water pipes,descaling/hard water scale cleaning and ,treatment for suport struture refitting the same in its own position of existing Solar Water Heater of capacity 300 to 500 LPD complete all as specified & directed.
192Supply and fixing in replacement of Solar water heater eliments 2000W to 3500W complete all as specified & directed.
193Supply and Fixing in replacement of solar hot water tank Capacity of 500 Ltr complete all as specified & directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56393938
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.77 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Internal Electrification, Cooling Appliances, Electric Supply Lt Cables, Lt Panels, Bollard Lighting, Street Light, Electric Poles, External Water Distribution Lines, Pump Motors & Dg Sets And Other Connected Works At Cgra And Otm Gopalpur Under Ge (I)(Cg) Bhubaneswar
Basic Detail
Tender No 8702/BBSR/06/E8
Bidding Type Tender
Location
City Ganjam
State Odisha
Key Dates
Publish Date 09 Jul 2026
Submission Date 30 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 14.77 Lakhs
Tender Fee 500
EMD 29540
Exemption Available
Document List
BOQ_870769.xls
fc98f9e1-0b83-45c7-ac8f-06578fd50e22.html
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_870769.xls

html

fc98f9e1-0b83-45c7-ac8f-06578fd50e22.html

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders