| Sl. No. | Item Description |
| 1 | M & L for taking down the defective Split Type AC Unit 1.5 TR Capacity, shifting to work shop, taking out the defective unserviceable Hermetically Sealed Compressor from the unit, replacing the compressor with New Compressor of the same capacity, fixing in the unit, interconnecting the Refrigerating Lines, flushing out the Cooling Coil & Condenser thoroughly for removing carbon deposits, cleaning with CTC, Leak Testing, pressure testing with Nitrogen Gas, Dehydrating, Vacuumising, Charging of Oil / Refrigerant Gas, testing at Workshop, shifting to the location and reinstalling the same in its original position, connecting up all electrical connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson. Note: Rate quoted is deemed to be inclusive of Cutting, Welding, Brazing, Sealing the Refrigerant Tubing, replacement of Strainer, CTC, Nitrogen Gas, Refrigerant Gas, to and from transportation and handling complete. |
| 2 | All as per Serial Item No. 1 above but Split Type AC Unit of 2.0 TR Capacity. |
| 3 | All as per Serial Item No. 1 above but Window Type AC Unit of 1.5 TR Capacity. |
| 4 | M & L for taking down the defective Outdoor unit of Split Type AC Unit of 1.5 TR / 2.0 TR Capacity of any Make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted sheet metal parts with the same thickness of MS Sheet as per the existing size & shape including cutting, bending, welding, drilling, fabricating etc., including renewal of all Nuts & Bolts, Sheet Metal Screws, Mounting Legs, Rubber Bushes and cleaning & prepare the surface thoroughly, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson |
| 5 | M & L for taking down the defective Window Type AC Unit of 1.5 TR / 2.0 TR Capacity of any make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted Sheet Metal Parts with the same thickness of MS Sheet as per the existing Size & Shape including Cutting, Bending, Welding, Drilling, Fabricating etc., including renewal of all Nuts & Bolts, Sheet Metal Screws, Rubber Bushes, cleaning & prepare the surface thoroughly, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson |
| 6 | S & F in repairs Condenser Fan Blade of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. |
| 7 | S & F in repairs Indoor Blower Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. |
| 8 | M & L for cleaning and preparing the surfaces of Outdoor unit of Split Type AC Unit of 1.5 TR / 2.0 TR Capacity of any Make thoroughly by scraping down old rusted paint by Steel Brush, Brooming, Rubbing and Cleaning thoroughly, filling Cavities with Filler / Metallic Paste etc. and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by Spray Painting and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components, Brazing the Refrigeration Piping and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. |
| 9 | M & L for cleaning, flushing the Refrigeration System of Window Type AC Unit of 1.5 TR / 2.0 TR Capacity of any make thoroughly with CTC and Nitrogen Gas, Leak Testing and locating the leaks, rectifying the leaks by brazing the joints, replacing the damaged Copper Pipes, Silver / Copper Rod, pressure testing with Nitrogen Gas, Dehydrating, Vacuumising, Charging of Oil / Refrigerant Gas, replacement of Strainer and connecting up all electrical connections and testing complete all as specified and as directed. |
| 10 | S & F in repairs Temperature Sensor Probe of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. |
| 11 | S & F in repairs Printed Circuit Board [PCB] of Dual Inverter 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. |
| 12 | S & F in repairs Sealed Fan Motor of Indoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make including testing & commissioning the unit complete all as specified as directed. Make: AUE / Free Flow |
| 13 | S & F in repairs Air Filter Set of 1.5 / 2.0 TR Capacity Split Type AC of any make as per OEM including testing & commissioning the unit complete all as specified as directed. |
| 14 | S & F in repairs 36/45 Mfd, Running Capacitor, +5% SH, 440 Volts, AC, 50 Hz including testing & commissioning the unit complete all as specified as directed. Make: Sarada / Unistar |
| 15 | S & F in repairs Running Capacitor of combination 45/2.5/45/4 Mfd, +5% SH, 440 Volts, AC, 50 Hz suitable for Compressor, Outdoor Unit Fan Motor of 1.5 / 2.0 TR Capacity Split Type AC complete all as specified and as directed. Make: Sarada / Unistar |
| 16 | S & F in repairs Starting Capacitor 80 / 100 Mfd, 240 Volts, AC, 50 Hz suitable for 1.5 / 2.0 TR Capacity Split Type / Window Type AC complete all as specified and as directed. Make: Sarada / Unistar |
| 17 | S & F in repairs Running Capacitor of 4/6 Mfd, 240 Volts, AC, 50 Hz suitable for Outdoor Unit 1.5 / 2.0 TR Capacity Split Type and Window Type AC complete all as specified and as directed. Make: Sarada / Unistar |
| 18 | S & F in repairs Starting Relay suitable for 1.5 / 2.0 TR Capacity Split Type / Window Type AC complete all as specified and as directed. Make: Aravind / Shriram |
| 19 | S & F in repairs Thermostatic Switch suitable for 1.5 / 2.0 TR Capacity Window Type AC complete all as specified and as directed. Make: Ranco / Danfoss / Honeywell / Indfoss |
| 20 | S & F in repairs Insulated Drain Pipe suitable for 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed. |
| 21 | S & F in repairs Capillary Tube Set suitable for 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed. |
| 22 | S & F in repairs MS Stand Suitable for Outdoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make, fixing with Anchor Fastner, Nut, Bolts and Rubber Bushes complete all as specified and as directed. |
| 23 | M & L for taking down the Burnt Fan Motor and Rewinding, Overhauling, replacement of worn out Shaft & Bushes and fixing to the Outdoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed. |
| 24 | M & L for taking down the Burnt Fan Motor and Rewinding, Overhauling, replacement of worn out Shaft & Bushes and fixing to the Outdoor Unit of 1.5 / 2.0 TR Capacity Window Type AC of any make complete all as specified and as directed. |
| 25 | Supply only Remote Control Unit Suitable for 1.5 / 2.0 TR Capacity Split Type AC of any make, complete all as specified and as directed. |
| 26 | S & F in repairs Condenser Fan Motor of Outdoor Unit of 1.5 / 2.0 TR Capacity Split Type AC of any make complete all as specified and as directed. |
| 27 | S & F in repairs New Wiring Kit Suitable for 1.5 / 2.0 TR Capacity Split Type / Window Type AC of any make, including testing & commissioning the unit complete all as specified as directed. |
| 28 | M & L for taking down by disconnecting Water Connections and shifting Water Coolers up to 120 Litres capacity to Workshop, taking down the defective sealed compressor and replace with New Compressor including flushing the complete system of Condenser, Cooling Coil with Nitrogen Gas, removal all Carbon, Oil & Dirt, Brazing & connecting the Refrigeration Lines, Dehydrating, Purging with Refrigerant, Vacuumising and charging with R22/134 Refrigerant Gas and testing & commissioning and shifting to original location and connecting up the electrical & water connections complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson |
| 29 | M & L taking down by disconnecting Water Connections of Water Coolers up to 120 Litres capacity for complete tinkering the corroded Sheet Metal Parts, Side Panel, Door and renewal of the Bottom Base Plate, Mounting Legs, Fan Motor Base Plate and Condenser Cover etc., with existing Size & Gauge GI Sheet, with required Angle Iron, Nut, Bolts all as per the existing size and shape including Cutting, Bending, Welding and fixing all other components and nesting the hole of watertight and making the door properly sit without any gap including float set and washer complete scraping old paint, prepare the surfaces, applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by spray painting duly filling cavities etc. and Writing MES No. & GE [P] [N] Kalinga as per standard size including complete cleaning the Water Tank and shifting to the original location and testing complete all as specified and as directed. |
| 30 | M & L for taking down 40/80 Litres capacity Water Coolers, transporting to workshop flushing out the Cooling Coil, Condenser, Brazing the Refrigerant Lines, replacing the Liquid Line, Copper Strainer, Leak Testing, Purging with Refrigerant, Vacuumising and Charging of R22 Gas, testing & commissioning and shifting of the location and connecting up the Electrical & Water connections etc. complete all as specified and as directed. Make: Carrier / LG / Samsung / Shriram / Voltas / Kirloskar / Tecumseh / Blue Star / Emerson |
| 31 | All as per Serial Item No. 30 above but 60/120 Litres capacity Water Coolers complete all as specified and as directed. |
| 32 | M & L for cleaning and preparing the surfaces of Water Coolers of Capacity up to 120 Litres of any Make thoroughly by scraping down old rusted paint by Steel Brush, Brooming, Rubbing and Cleaning thoroughly, filling Cavities with Filler / Metallic Paste etc. and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by Spray Painting and Writing MES No. & GE [P] [N] Kalinga as per standard size including complete cleaning the Water Tank and shifting to the original location and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. |
| 33 | M & L for dismantling the Water Coolers up to 120 Litres capacity, checking for the leaks by Pressure Testing and carrying out the lead soldering to Cooling Coil and the tank outer surface wherever found detached including rectifying the leakages and re-assembling the Water Cooler complete all as specified and as directed. |
| 34 | S & F in repairs Starting Relay suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Aravind / Shriram |
| 35 | S & F in repairs Over Load Relay suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Aravind / Shriram |
| 36 | S & F in repairs Running Capacitor 20/10 Mfd, 440 Volts, AC, 50 Hz suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Sarada / Unistar |
| 37 | S & F in repairs Starting Capacitor 60/80 Mfd, 240 Volts, 270 SU, 50 Hz suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Sarada / Unistar |
| 38 | S & F in repairs Thermostatic Switch suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. Make: Annapurna / Rantro / Indfoss |
| 39 | S & F in repairs Chromium Plated Lift / Push Type Bib Cock of 15mm bore suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. |
| 40 | S & F in repairs Brass Float Valve of 15mm bore suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. |
| 41 | S & F in repairs Drain Connection and Drain Pipe of 3.0 to 5.0 m length with necessary Clamps, Nipple, Coupling etc., suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. |
| 42 | S & F in repairs Fan Motor suitable for 40 / 80 & 60 / 120 Litres Capacity Water Coolers complete all as specified and as directed. |
| 43 | S & F in repairs Fan Blade suitable for 40 / 80 & 60 / 120 Litres Capacity Water Coolers complete all as specified and as directed. |
| 44 | S & F in repairs Air Cooled Condenser with necessary brackets and fixing arrangements including welding brazing etc., suitable for Water Cooler up to 120 Litres capacity complete all as specified and as directed. |
| 45 | S & F Sealed Compressor suitable for Refrigerator of 180/230 Litres Capacity, Flushing out the Cooling Coil, Condenser, brazing the Refrigerant Lines, Leak Testing, Pressure Testing, Purging, Vacuumising, Charging of Gas, Testing & Commissioning including taking down the defective sealed compressor complete all as specified and as directed. Make: LG / Hitachi / Indfoss |
| 46 | All as per Serial Item No. 45 above but Refrigerator of 280 Litres capacity complete all as specified and as directed. |
| 47 | S & F in repairs Relay suitable for Refrigerator up to 230 Litres Capacity complete all as specified and as directed. Make: As per OEM |
| 48 | S & F in repairs Thermostatic Switch suitable for Refrigerator up to 230 Litres Capacity complete all as specified and as directed. Make: As per OEM |
| 49 | S & F in repairs, Single Pole Contactor of Capacity 30 Amps, 240 Volts, 50 Hz suitable for Split / Window type ACs complete all as specified and as directed. |
| 50 | S & F Sheet Metal Body of Outdoor unit of 1.5 TR capacity Split AC Unit of any Make / Model including taking down and dismantling the components and reassembling and fixing to the existing location and testing for complete all as specified and as directed. |
| 51 | S & F Sheet Metal Body of Outdoor unit of 2.0 TR capacity Split AC Unit of any Make / Model including taking down and dismantling the components and reassembling and fixing to the existing location and testing for complete all as specified and as directed. |
| 52 | S & F in repairs Air Cooled Condenser suitable for 1.5 TR capacity Split AC Unit of any Make / Model and testing for complete all as specified and as directed. |
| 53 | S & F in repairs Air Cooled Condenser suitable for 2.0 TR capacity Split AC Unit of any Make / Model and testing for complete all as specified and as directed. |
| 54 | Supply & filling Refrigerant Gas R-22 / R32 / R410 A for charging of Split / Window type AC, Refrigerator / Deep Freezer and Water Cooler of any capacity and any make complete all as specified and directed. |
| 55 | Taking down Split Air Conditioner including Outdoor unit of any description from its position and refixing the same at same place or at new place including connecting up, cleaning, carrying out minor repairs and replacement of Nuts & Bolts etc. including MS Stand / Bracket suitable for fixing Outdoor Units of Split ACs of different capacities, recharging with suitable Refrigerant Gas as required and necessary scaffolding etc. for complete all as specified and as directed. |
| 56 | S & F in repairs 3/8\\" dia Copper Pipe suitable for Split type Air conditioners and connecting between Indoor and Outdoor unit including fixtures and duly insulated with 10mm thick Nitrile Rubber Insulation complete all as specified and directed. |
| 57 | S & F in repairs 1/4\\" dia Copper Pipe suitable for Split type Air conditioners and connecting between Indoor and Outdoor unit including fixtures and duly insulated with 10mm thick Nitrile Rubber Insulation complete all as specified and directed. |
| 58 | S & Fixing in repairs 4 Core, PVC Insulated, Sheathed Flexible Copper Conductor Cable of size 4 Sq.mm and connecting up Air Conditioners of any type and Capacity complete all as specified and as directed. |
| 59 | M&L for carrying out the complete servicing to Window Type ACs including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carrying out the chemical cleaning to chocked Cooling Coil & Condenser Coil, by spraying the Dilated Chemical Cleaning Agent till removal of complete chocking, flushing across the Coils, cleaning all the Sheet Metal Parts, Filter, Grill and fixing all the dismantled parts with Sheet Metal Screws, lubricating the fan Motor Bush / Bearing, checking all the Electrical Connections, renewing the Burned Legs/Clip if any and fixing back to position and testing complete all as specified and as directed. Note: Servicing to be done by air blower and dust cleaner machines. |
| 60 | All as per Serial Item No. 59 above but for Split Type ACs of 1.5 / 2.0 TR Capacity complete all as specified and as directed. |
| 61 | S & F in repairs Suction and Liquid Line Insulation, Thermo Foam, Pipe Section Type, suitable for Split Type ACs of 1.5 / 2.0 TR Capacity complete all as specified and as directed. |
| 62 | S & F in repairs PVC Air Filter Set of 3 suitable for Split Type ACs of 1.5 / 2.0 TR Capacity complete all as specified and as directed. |
| 63 | S & F in repairs Powder Coated Sheet Metal Body Outer Cover Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, including testing & commissioning the unit complete all as specified as directed. |
| 64 | S & F in repairs Condenser Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, including testing & commissioning the unit including necessary piping and brazing complete all as specified as directed. |
| 65 | S & F in repairs Evaporator Coil Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, including testing & commissioning the unit including necessary piping and brazing complete all as specified as directed. |
| 66 | S & F in repairs Front Decorative Grill Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, complete all as specified as directed. |
| 67 | S & F in repairs Fan Motor Double End Shaft Type Suitable for 1.5 / 2.0 TR Capacity Window Type AC of any make, complete all as specified as directed. |
| 68 | M & L for taking down the Defective Deep Freezer of 300 Litres capacity, shifting to work shop, taking out the defective Sealed Compressor from the unit and replacing the compressor with the Factory Reconditioned Compressor of the same Make and Capacity, flushing out the Cooling Coils and Condenser with CO2 / Nitrogen Gas, removal of complete Oil and Carbon Chocking, Brazing Lines interconnection, renewal of the Drier Filter, Pressure Testing, Vacuumising, Dehydration, Charging of R-134a Gas, testing at work shop and transportation back to the site and refixing the Deep Freezer in its original position complete all as specified and as directed. Make: LG / Danfoss |
| 69 | All as per Serial Item No. 68 above but Deep Freezer of 500 Litres Capacity complete all as specified and as directed. |
| 70 | S & F in repairs Fan Motor with Fan Blades suitable for 425 Litres Capacity Deep Freezer complete all as specified and as directed. |
| 71 | S & F in repairs Electronic wall mounted time delay Voltage stabilizer of 5 KVA Capacity, Automatic Operation, for input variation of 170 Volts to 270 Volts with stabilised voltage of 230 Volts with accuracy of ± 2.5% complete all as specified and as directed Make: V Guard / Servo / Kee Line |
| 72 | S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed. |
| 73 | S & F in repairs Capacitors of 2.5 Mfd Capacity complete all as specified and directed. Make: Usha / Crompton / Tibcon / Universal |
| 74 | Dismantling the Ceiling Fan and its Allied Minor Spares / Parts and taking out the Bearings / Bushes and refixing the same with all the parts i.e. Down Rod, Canopies, Fan Blades etc. replacing the damaged Spilt Pins and Screws, Nuts and Spring Washers [for Blade/Body] including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm as required complete all as specified and as directed. Note: Supply only spares like Bearings / Bushes, Blades, Down Rod, Capacitor, Shackle & Clamp and Canopy shall be measured and paid separately as supply only under this BoQ. Rewinding of Fan Motor Shall also be measured and paid separately wherever ordered. |
| 75 | All as per Serial Item No. 74 above, but Exhaust Fan of any Sweep complete all as specified and as directed. |
| 76 | All as per Serial Item No. 74 above but Air Circulator of any Sweep complete all as specified and as directed. |
| 77 | All as per Serial Item No. 74 above, but Wall Mounted Fan of any Sweep complete all as specified and as directed. |
| 78 | All as per Serial Item No. 74 above but Pedestal Fan of any Sweep complete all as specified and as directed. |
| 79 | M & L for Rewinding of Motor of Ceiling Fan of 1200mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed. |
| 80 | M & L for Rewinding of Motor of Exhaust Fan of 300mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed. |
| 81 | M & L for Rewinding of Motor of Exhaust Fan of 400 / 450mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed. |
| 82 | M & L for Rewinding of Motor of Wall Mounted Fan of 400 / 450mm Sweep and of any description using Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., Cleaning, Greasing etc. complete all as specified and directed. |
| 83 | Supply only Ball Bearing No. 6201 / 6202 suitable for Ceiling Fan / Exhaust Fan / Wall Mounted Fan / Air Circulator / Pedestal Fan of any Sweep and any description complete all as specified and directed. Make: TATA / SKF / NBC |
| 84 | Supply only Ball Bearing No. 6203 / 6204 suitable for Ceiling Fan / Exhaust Fan / Wall Mounted Fan / Air Circulator / Pedestal Fan of any Sweep and any description complete all as specified and directed. Make: TATA / SKF / NBC |
| 85 | Supply only Capacitors of 2.5 Mfd Capacity complete all as specified and directed. Make: Usha / Crompton / Tibcon / Universal |
| 86 | Supply only Gun Metal Bush of any size complete all as specified and directed. Make: TATA / MSP |
| 87 | Supply only Shackle & Clamps including, Rubber Bush, Bolts, Nuts & Split Pin etc. complete suitable for Ceiling Fan of any Sweep and any description complete all as specified and directed. |
| 88 | Supply only MS Down Rod of size 15 mm bore, 500mm Long including making Two No. of Holes on either ends suitable for fixing Bolts of 8mm Dia suitable for Ceiling Fan of any Sweep and any description complete all as specified and directed. |
| 89 | S & F in repairs Electronic Fan Regulator, Stepped Type, Flush Type, AC, 230 Volts, Single Pole complete all as specified and as directed. |
| 90 | S & F in repairs Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed. |
| 91 | M & L for preparation of surfaces including filling Cavities with Filler / Metallic Paste etc. of Ceiling Fan of any Sweep and applying One Coat of Synthetic Enamel Paint of approved colour by Spray Painting and Writing MES Serial Number as per Standard Format Complete all as specified and as directed. |
| 92 | M & L for preparation of surfaces including filling Cavities with Filler / Metallic Paste etc. of Exhaust Fan of any Sweep and applying One Coat of Synthetic Enamel Paint of approved colour by Spray Painting and Writing MES Serial Number as per Standard Format Complete all as specified and as directed. |
| 93 | Supply only Three Core, PVC insulated, sheathed flexible Copper Conductor Cable of size 1.5 Sq.mm, 1100 Volts Grade complete all as specified and as directed. |
| 94 | M & L for Comprehensive Repair / Maintenance of Storage Type Electric Water Heater [Geyser] Vertical or Horizontal type of Capacity 25 Litres comprising of the following: [a] Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank complete to the satisfaction of the User / Engineer-in-Charge. [b] Checking of all Stop Cock, Pressure Release Valves, Fusible Plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the Washers / Gasket, Nuts etc.[c] Checking and rectifying Earth Continuity of the Electrical Circuits of the Geysers and Power Point. [d] Checking and re-fixing Thermostat and re-adjusting.[e] De-scaling the Immersion Type Heating Element and Siphon Assembly with diluted Hydrochloric Acid or clear Pedette Solution.[f] Checking of Indicator Lamp for its serviceability.[g] Re-assembling the Geyser, re-installing and testing complete.Note: Spares / Parts / Components of Geysers found unserviceable shall be replaced by the contractor. New Spares / Parts / Components as required shall be measured and paid separately under respective Items of this BoQ as supply only. |
| 95 | M & L for Comprehensive Repair / Maintenance of Solar Water Heater [Geyser], Vertical or Horizontal type of Capacity 100 / 500 Litres comprising of the following: [a] Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank complete to the satisfaction of the User / Engineer-in-Charge. [b] Checking of all Stop Cock, Pressure Release Valves, Fusible Plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the Washers / Gasket, Nuts etc.[c] Checking and re-fixing Solar Flat Plate Collector / Tube Collector and re-adjusting as required.[d] De-scaling the Immersion Type Heating Element with diluted Hydrochloric Acid or clear Pedate Solution.[f] Re-assembling the Solar Water Heater Tank, Solar Water Tube Collector / Flat Plate Collector re-installing and testing complete.Note: Spares / Parts / Components of Geysers found unserviceable shall be replaced by the contractor. New Spares / Parts / Components as required shall be measured and paid separately under respective Items of this BoQ as supply only. |
| 96 | Supply only Thermostat including Rubber / PVC Gasket Tube Set to a Temperature not higher than the range of 70°C suitable for 25/50 Litres Capacity Geyser complete all as specified and as directed. |
| 97 | Supply only Thermostat including Rubber / PVC Gasket Tube Set to a Temperature not higher than the range of 70°C suitable for 100 / 500 Litres Capacity Geyser complete all as specified and as directed. |
| 98 | Supply only Heating Element of capacity 2.0 KW including Rubber Gasket & Washer etc. as per existing Make / OEM complete all as specified and as directed. |
| 99 | Supply only Heating Element of capacity 3.0 KW including Rubber Gasket & Washer etc. as per existing Make / OEM complete all as specified and as directed. |
| 100 | Supply only Heating Element of capacity 1.5 KW including Rubber Gasket & Washer etc. as per existing Make / OEM complete all as specified and as directed. |
| 101 | Supply only Copper Syphon Assembly suitable for 25 Litre Capacity Geysers of any make as required at site / as per existing Model / Make complete with Inlet and Outlet and provision for Thermostat Pipe with Drain Pipes with Drain Plug, Screws, Studs, Clamps for fixing Heating Elements etc. including Gasket complete all as specified and as directed. |
| 102 | Supply only Plug Top 3 Pin, 16 Amps, 240 Volts complete all as specified and as directed. |
| 103 | Supply only 3 Core, PVC Insulated, Sheathed Flexible Copper Conductor Cable of size 2.5 Sq.mm suitable for connecting up Geyser complete all as specified and as directed. |
| 104 | Supply only LED Neon type Indicating Lamp [Green / Red], 240 Volts, AC, 50 Hz suitable for Geysers complete all as specified and as directed. |
| 105 | Supply only Safety Valve suitable for 25/50 Litres Capacity Geyser complete all as specified and as directed. |
| 106 | Supply only Plug Top 3 Pin, 20 Amps, 240 Volts complete all as specified and as directed. |
| 107 | M & L for Detecting and Arresting of leakage in Storage Tank of 25 Litres Capacity Geysers by Brazing and Soldering at leakage point and testing complete all as specified and as directed. |
| 108 | M & L for cleaning and preparing the surfaces of 25 Litres Capacity Geysers of any Make thoroughly by scraping down old rusted paint by Steel Brush, Brooming, Rubbing and Cleaning thoroughly, filling Cavities with Filler / Metallic Paste etc. and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide / Zinc Chrome Primer by Spray Painting and Writing MES No. & GE [P] [N] Kalinga as per standard size and fixing of all components and fixing in its original position and connecting up all Electrical Connections and testing complete all as specified and as directed. |
| 109 | S & F in repairs PVC Connection for Hot & Cold Water of 15mm Bore and 450mm long with PTMT check nut and union etc complete all as specified and as directed. |
| 110 | S & F in repairs PVC Connection for Hot & Cold Water of 15mm Bore and 600mm long with PTMT check nut and union etc complete all as specified and as directed. |
| 111 | S & F in repairs Non Return Valve, Cast Copper Alloy, Capstan Head, Chromium Plated, Fancy Type, 15 mm dia, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as specified and as directed. |
| 112 | Supply only Anchor Bolt of size 10mm dia and 100mm Long Bolt including Nut, Washer for mounting the Geyser complete all as specified and as directed. |
| 113 | S & F Energy efficient, BEE 5 Star rated Storage type Water Heater [Geyser] of 25 Litres Capacity with 2000 Watt Capacity Heating Element, Conforming to IS - 2082, Vertical Storage type with Stainless Steel Inner Tank and ABS Outer Shell complete fixed to wall with suitable expansion fasteners including 15mm dia PVC Flexible Hot & Cold Water connections and 15mm bore Brass Chromium Plated Non-Return Valve including taking out old unserviceable Geyser and depositing to MES Store Yard complete as specified and as directed. |
| 114 | Supply only MS Hooks of required size suitable for Ceiling Fan of any Sweep and any description complete all as specified and directed. |
| 115 | S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 373, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, of approved colour including Down Rod, Canopies, 3 Nos. Blades, Shackles, Safety Rope, Hanging Clamps, Bushes and having P.F >0.94, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% with speed control by Electronic Regulator including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Ceiling Fan of any description and depositing at MES Store Yard complete all as specified and as directed. |
| 116 | S & F Wall Mounted Fan, 400mm Sweep, Metal Body, Heavy duty, 230 Volts, AC, 50 Hz, Wall Mounting Type including speed control set and including taking down existing Wall Mounted Fan of any description and depositing at MES Store Yard complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender