Tender For Tender For Restoration Of Damaged Ht And Lt Line At Baijnath Due To Heavy Rain & Thunderstorm During April-May 2026 At Various Sections Bir, Sehal, Harer,Chobin, Sakri, Kunsal, Paprola, Panchrukhi-01 And Alhilal Under Ed Hpsebl Baijnath.
Tender Overview
Project Description
Tender for Tender For Restoration Of Damaged Ht And Lt Line At Baijnath Due To Heavy Rain & Thunderstorm During April-May 2026 At Various Sections Bir, Sehal, Harer,Chobin, Sakri, Kunsal, Paprola, Panchrukhi-01 And Alhilal Under Ed Hpsebl Baijnath.
BOQ
| Sl. No. | Item Description |
| 1 | Restoration of LT line damaged due to heavy rain & thunder storm at Keori in E-Section Bir under ESD Baijnath on Dt. 08.04.2026 |
| 2 | AAAC 7/3.15mm (50mm²) |
| 3 | Erection charges of Conductor |
| 4 | Erection charges of Jumper |
| 5 | Erection charges of GI Wire |
| 6 | Transportation charges |
| 7 | GST on Erection & Transportation |
| 8 | Restoration of LT line damaged due to heavy rain & thunder storm at Forest Rest House, Keori, Kotli in E-Section Bir under ESD Baijnath on Dt. 11.05.2026 |
| 9 | AAAC 7/3.15mm (50mm²) |
| 10 | AAAC 6/1/2.59mm (30mm²) |
| 11 | AAAC 7/3.81mm (80mm²) |
| 12 | Erection charges of Conductor 30mm |
| 13 | Erection charges of Conductor 50mm |
| 14 | Erection charges of Conductor 80mm |
| 15 | Erection charges of Jumper |
| 16 | Transportation charges |
| 17 | GST on Erection & Transportation |
| 18 | Restoration of HT line due to rain & thunderstorm Sehal in Electrical section Sehal Under ESD Baijnath on dated 11.05.2026. |
| 19 | Prov. S/T Pole 09 Mtr. Long. |
| 20 | Prov. RCC Muff with concrete filling (2000 mm). |
| 21 | Prov. AAAC 7/3.15 mm |
| 22 | Prov. MS Channel iron (100x50x6), Length 2800mm |
| 23 | Prov. MS Channel iron (100x50x6), Length 1800mm |
| 24 | Prov. MS Angle iron (50x50x6), Length 1800mm |
| 25 | Erection Charges for Steel Tubular HT poles. |
| 26 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 27 | Re-Sagging Charges single continuous GI wire. |
| 28 | Erection of Jumpers |
| 29 | Transportation charges |
| 30 | GST on Erection & Transportation |
| 31 | Restoration of LT line due to rain & thunder storm Sehal in Electrical section Sehal Under ESD Baijnath on dated 11.05.2026 |
| 32 | Prov. Stay Wire 7/3.15 mm |
| 33 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 34 | Add. Re-Sagging Charges single continuous GI wire. |
| 35 | Transportation charges |
| 36 | GST on Erection & Transportation |
| 37 | Restoration of HT & LT line due heavy strom at various locations in Electrical section Harer Under ESD Baijnath on dated 11.05.2026. |
| 38 | Prov. S/T Pole 09 Mtr. Long. |
| 39 | Steel Tubular Poles (8 mtr) |
| 40 | Prov. RCC Muff with concrete filling (2000 mm). |
| 41 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 42 | Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more |
| 43 | Prov. Half Clamp (M.S. Flat 50x6 mm). |
| 44 | Prov. Full clamp |
| 45 | Prov. Aluminium Paint. |
| 46 | Prov. MS Channel iron (100x50x6), Length 2800mm |
| 47 | Prov. MS Channel iron (100x50x6), Length 1800mm |
| 48 | Prov. MS Angle iron (50x50x6), Length 1800mm |
| 49 | Prov. MS Angle iron (50x50x6), Length 2125mm |
| 50 | Erection Charges for Steel Tubular HT poles. |
| 51 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 30mm |
| 52 | Erection of Jumpers |
| 53 | Transportation charges |
| 54 | GST on Erection & Transportation |
| 55 | Restoration of HT line damage due to rain & thunder storm at Marh,Gawal,Shanti Nagar in E-Section Chobin Under ESD Kudail on Dt. 11-05-2026 |
| 56 | Prov. S/T Pole 09 Mtr. Long. |
| 57 | Prov. RCC Muff with concrete filling (2000 mm). |
| 58 | Prov. AAAC 7/3.15 mm |
| 59 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 60 | Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure). |
| 61 | Prov. Egg Insulator |
| 62 | Prov. Stay Wire 7/3.15 mm |
| 63 | Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 64 | Prov. Full clamp |
| 65 | Prov. MS Angle iron (50x50x6), Length 1800mm |
| 66 | Prov. MS Angle iron (50x50x6), Length 2125mm |
| 67 | Erection Charges for Steel Tubular HT poles. |
| 68 | Erection charges for conductor |
| 69 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 70 | Re-Sagging Charges single continuous GI wire. |
| 71 | Erection of HT Stay sets. |
| 72 | Erection of Jumpers |
| 73 | Transportation charges |
| 74 | GST on Erection & Transportation |
| 75 | Restoration of LT line damage due to rain & thunder storm at Bheot,balh,Marh & Pirh in E-Section Chobin Under ESD Kudail on Dt. 11-05-2026 |
| 76 | Prov. S/T Pole 08 Mtr. Long. |
| 77 | Erection Charges for Steel Tubular poles. |
| 78 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 79 | Re-Sagging Charges single continuous GI wire. |
| 80 | Erection of Jumpers |
| 81 | Transportation charges |
| 82 | GST on Erection & Transportation |
| 83 | Restoration of HT line damage due to rain & thunder storm at Pahloon & Langhu in E-Section Sakri Under ESD Kudail on Dt. 11-05-2026 |
| 84 | Prov. AAAC 7/3.15 mm |
| 85 | Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides). |
| 86 | Erection charges for conductor |
| 87 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 88 | Re-Sagging Charges single continuous GI wire. |
| 89 | Erection of HT Stay sets. |
| 90 | Erection of Jumpers |
| 91 | Transportation charges |
| 92 | GST on Erection & Transportation |
| 93 | Restoration of LT line damage due to rain & thunder storm at Mahalpatt, Langhu, Gadiyara, Rainabadi in E-Section Sakri Under ESD Kudail on Dt. 11-05-2026 |
| 94 | Prov. LT Stay Set. |
| 95 | Prov. AAAC 7/3.15 mm |
| 96 | Prov. Stay Wire 7/3.15 mm |
| 97 | Erection Charges for conductor 7/3.15mm |
| 98 | Erection of LT Stay sets. |
| 99 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 100 | Re-Sagging Charges single continuous GI wire. |
| 101 | Erection of Jumpers |
| 102 | Transportation charges |
| 103 | GST on Erection & Transportation |
| 104 | Restoration of LT line damage due to rain & thunder storm at Chakoli,Mahlpatt & Nohra in E-Section Kunsal Under ESD Kudail on Dt. 11-05-2026 |
| 105 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 106 | Re-Sagging Charges single continuous GI wire. |
| 107 | Erection of Jumpers |
| 108 | GST on Erection & Transportation |
| 109 | Restoration of HT line damaged due to rain & thunderstorm in Electrical section Panchrukhi No. 1 Under ESD Panchrukhi on dated 11.05.2026 |
| 110 | Prov. S/T Pole 09 Mtr. Long. |
| 111 | Prov. RCC Muff with concrete filling (2000 mm). |
| 112 | Prov.AAAC 7/3.15 mm sq. (50 mm sq.) additional 3% (sag,Jumpering wastage}. |
| 113 | Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides). |
| 114 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 115 | Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 116 | Prov. Half Clamp (M.S. Flat 50x6 mm). |
| 117 | Prov. Full clamp |
| 118 | Prov. Aluminium Paint. |
| 119 | Prov. MS Channel Iron: 100x50x5 , Length: 1800 mm |
| 120 | Prov. MS Angle Iron : 50X50x6, Length:(1800 mm x 2 No. ) |
| 121 | Erection Charges for Steel Tubular HT poles. |
| 122 | Erection Charges for Re sagging, stringing & binding with insulator of conductor AAAC 50 mm2. |
| 123 | Erection of Jumpers |
| 124 | Transportation charges |
| 125 | GST on Erection & Transportation |
| 126 | Restoration of LT line damaged due to rain & thunderstorm in Electrical section Panchrukhi No. 1 Under ESD Panchrukhi on dated 11.05.2026 |
| 127 | Prov. Schackle Insulator |
| 128 | Prov. D-Iron |
| 129 | Prov. Full clamp |
| 130 | Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 131 | Prov. Channel Iron (75x40x4.8) [Length- 1.50 Mtr + 0.2 Mtr] |
| 132 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 133 | GST on Erection & Transportation |
| 134 | Restoration of damaged LT lines at various locations at E-Section Alhilal Under ESD Paprola on Dt. 10.05.2026 |
| 135 | Prov. S/T Pole 09 Mtr. Long. |
| 136 | Prov. RCC Muff with concrete filling (2000 mm). |
| 137 | Prov. LT Stay Set. |
| 138 | Shackle Insulator |
| 139 | D/iron |
| 140 | Prov. G.I. Wire 8 SWG |
| 141 | ACSR/AAAC 7/3.15 mm |
| 142 | Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 143 | Prov. Aluminium Paint. |
| 144 | Prov. Stay Wire 7/3.15 mm |
| 145 | Erection Charges for Steel Tubular poles. |
| 146 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 147 | Erection of LT Stay sets. |
| 148 | Re-Sagging Charges single continuous GI wire. |
| 149 | Transportation charges |
| 150 | GST on Erection & Transportation Quantities are mentioned above are tentative and Actual Quantity shall be worked out after Check Survey to be carried out by the successful Tender and detailed Engineering and finalization of Tower location Chart.Payment shall be made as per Approved Bill of Material/Actual Quantities measured at site. Other Material like pole & Conductor will be provided by HPSEBL Divisional Store Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender