Tender For Restoration Of Damages Lwss Joharji In Tehsil Kasauli District Solan (Hp) (Sh: supply erection Of Centrifugal Pumping Machinery Along With Allied Accessories Lwss Joharji 1St Stage) (Under Pdna).
Tender Value
8.40 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
0 days left
EMD
16800
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Restoration Of Damages Lwss Joharji In Tehsil Kasauli District Solan (Hp) (Sh: supply erection Of Centrifugal Pumping Machinery Along With Allied Accessories Lwss Joharji 1St Stage) (Under Pdna).
BOQ
| Sl. No. | Item Description |
| 1 | Providing Installation i/c testing and commissioning at site horizontal spindle horizontal split casing/end suctions (back full out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/ KSB/ Kirloskar /Becon weir/BE/Jyoti as per IS-1520-1980 / IS 5659 - 1970 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear / raw water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage / Slipring drip proof induction motor of standard make such as Kirloskar /Crompton /Bhel/NGEF/GEC/Siemen/Jyoti/ABB and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- |
| 2 | Discharge (Q) : - 7.250 LPS |
| 3 | Total dynamic head : 297 mtrs. |
| 4 | (a) LWL in sump well (h) : |
| 5 | (b) Shaft level : |
| 6 | (c ) Level at discahrge point : |
| 7 | (d) Suction lift : |
| 8 | (e) Residual head : |
| 9 | (f) Static head : |
| 10 | (i) Rising Main : |
| 11 | (a) Length 1500 Mtrs |
| 12 | (b) Dia. :100 mm |
| 13 | (iv) Pumping Hours : 8 Hours. |
| 14 | Altitude of installation above MSL:- |
| 15 | Characteristic of Water |
| 16 | Temperature:- |
| 17 | Ambient |
| 18 | Alkalinity :- Mg/CaCo3 |
| 19 | Size of the Solids (mm) |
| 20 | Other |
| 21 | (Including following accessories) |
| 22 | Providing ICTP Main Switch with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB. |
| 23 | Providing Installation i/c testing and commissioning at site A.C.B./ OCB of Kilburn/ Havell/MDS/Standard/ L&T/MEI/GEC make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
| 24 | Providing Installation i/c testing and commissioning at site suitable oil immersed star delta/ direct on line/ Auto trasformer/ starter rotor starter of MEI/ Kilburn/ Jyoti/ L&T/ Siemens make as per IS: 8544 -1979 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
| 25 | Providing double flanged cast Iron sluice valve of Leader/Kirloskar make of 80mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 780-1984 with up to date amendments. |
| 26 | P/F double flanged cast steel sluice valve of Kirloskar/KSB/Leader make and of class-600 for rising main and capable of with standing normal seat pressure as per relevant IS specifications with upto date amendments including rubber, gaskets, nuts and bolts complete in all respect and to the entire statisfaction of Engineer-in-Charge (65 mm dia). |
| 27 | P/F double flanged cast steel swing type non return valves class-600 and of leader/ KSB?Kirloskar make on delivery line capable of with standing the normal seat pressure per relevant IS code with upto date amendments including rubber, gaskets, nuts and bolts complete in all respect and to the entire statisfaction of Engineer-in-Charge 65 mm dia complete in all respect. |
| 28 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor complete in all respects. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender