Tender for Construction Of Hostel At Mrcfc Khudwani, Skuast-K (Capex).

BOQ

Name of Work:- Construction of Hostel at MRCFC Khudwani, SKUAST-K (CAPEX).
Sl. No. Item Description
1STRUCTURAL
2EARTHWORK: Earth work excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables, etc (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift up to 1.5m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres, all kinds of soil. Including dewatering if any from foundation upto plinth level.
3STONE SOLING: Providing and laying of hand packed stone soling (size 150 mm-230mm), before laying of mud mat, compacted, consolidated, rammed and filling the voids with fine sand - all complete incl carriage upto site of work with all head loads.
4MUDMAT: Cast-in-situ of concrete work of nominal mix concrete M7.5 grade (1:4:8) nominal maximum size of stone aggregate 40mm volumetric batching in foundation trenches and ground floor, including curing but excluding formwork costs.
5MASS CONCRETE: Providing and laying mass concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in Below Ground and Above Grouns Plinth retaining walls, (any thickness) including attached pilasters, including curing but excluding the cost of centring, shuttering and finishing with
6CAST-IN-STU DESIGN MIX M25: Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,incluyding pumping of concrete to site laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportiond as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable seperately all works Below Plinth Levl / Above Plinth Level upto level V (AGL/BGL).
7UPTO PLINTH LEVEL
8ABOVE PLINTH LEVEL
9EXTRA CEMENT QUANTITY: For design mix M25 over 330kg/m3
10FORM WORK: Centering and shuttering including strutting, propping etc. and removal of formwork from the site, for all works from foundations, to roof level
11BELOW PLINTH LEVEL
12ABOVE PLINTH LEVEL
13SLAB EDGES
14PLINTH FILLING: Supplying and filling in plinth with GSB/ Second class sand under floors including, watering, ramming, consolidating and dressing complete including carriage, leads and lifts.
15BACK FILLING: Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
16STEEL REINFORCEMENT: Steel reinforcement for R.C.C. works including straightening, cutting, bending, placing in position and binding - all complete from foundation to roof level of Thermo-Mechanically Treated bars of grade Fe-500D or higher.
17EXPANSION JOINTWALLS
18STRUCTURAL STEEL:Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. plates, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer also included.
19ANCHOR BOLTS: Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
20ARCHITECTURAL
21Brick work with common burnt clay F.P.S (non modular) bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :(Cement mortar 1 :6 (1 cement : 6 coarse sand)
22Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
23Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level in all shapes and sizes in :(Cement mortar 1 :4 (1 cement : 4 coarse sand) Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.
2415mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand)
2512mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand)
26Providing and fixing of U-PVC sliding/casement/fix window in white colour,frame 60mm thick (min) x 90mm (min) with 1.5 mm GI reinforcement sash 39mm (min) 58mm (min) with 1.25mm GI U section reinforcement with rubber gasket of grey / black colour 10 years warranty against weathering of profile with complete hardware fittings and with 5mm thick toughened glass and fiber jalli option pre- febricated on german fabrication system( mosquito sash 18mm(min) x 43mm(min)(with welled cornes) complete at site (for glazing/wire guage shutters)
27Providing and fixing of U-PVC sliding/casement/fix doors in whote colour,frame 60mm thick (min) x 45mm (min) with 1.5 mm GI reinforcement sash 39mm (min) 58mm (min) with 1.25mm GI U section reinforcement with rubber gasket of grey / black colour 10 years warranty against weathering of profile with complete hardware fittings fixed with 12mm thick laminated board panels as per design and with 5mm toughened glass and fiber jalli option if pre- febricated on german fabrication system( mosquito sash 18mm(min) x 43mm(min)(with welled cornes) complete at site including all fixtures
28Providing and fixing wood work in frames of doors, windows and other frames, wrought framed and fixed in position including SS expansion fastners for brick / concrete work in (including cost of all material, leads, lifts and carriages etc upto site of work complete wood as per the directions of Consultant/as per the drawings enclosed First class deodar wood
29Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative / non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
30Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
31Providing and fixing hardware fittings of approved brand and of required type as approved by Engineer incharge. complete as per the specifications . (Brass)
32Modular door lock ss finish handle 10\\" with duaal locking system inside & outside (godrej)
33L -drop (300 x 16mm)
34Tower bolts 150mm (doors)
35Handle 125mm (door)
36Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
37Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
38Granite Work in Floors :- Providing and fixing ( gang saw cut mirror polished (flamed , pre-moulded and pre-polished), machine cut for flooring, steps ,risers of stairs etc.( flamed instaircase) of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding (of edges wherever required ) and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shape 16mm thick. and slab area over 0.50 sq m. (Note: The Granite stone slab shall be cut to required size and laid to the required pattern including rounding, chamfering, bull nosing of the edges as directed. Actual area of slab, as laid shall be measured) Sample to be approved by Engineer-in-charge. (including cost of all material, leads, lifts and carriages etc. upto site of work complete.
39Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.(Size 1200 x 600 mm)
40Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
41Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
42Providing and fixing ist quality ceramic glazed tiles in floors ( thickness to be specified by the manufactures) confirming to IS: 13753 of approved make like NITCO, Orient, Somany, Kajaria or equivalent make of specified shades except Burgundy bottle green black of any size as approved by consultant over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3Kgs per Sq.m including pointing in white cement mixed with pigment of matching shade complete In all colours, shades, except White, Ivory, Fume Red Brown(600mm x600 mm )
43Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. SizeTile 600 x 1200 mm. (including cost of all material, leads, lifts and carriages etc upto site of work complete).
44Providing and fixing devri stone 25 mm thick with exposed face fine dressed with rough backing on floor / ramp / plinth face etc. upto 10 meter ht back filled with a grout of 50 mm thick cement sand mortar in 1:3 (fine cheiseled)including pointing in white cement 1:2 with admixture of pigment matching to stone
45Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc.,by applying cemnet slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement@ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement compound @ 0.126 kg/sqm. This layer will be allowed t air cure for 4 hours followed with water curing of 48 hours. The rate includes preparation of surface, treatment and sealingof all joints ,ciorners, juntions of pipes and masonry with polymer mixed slurry.
46French spirit polishing, Two or more coats on new works including a coat of wood filler ( FLUSH DOORS )
47Providing and applying cement based wall putty of required thickness over plastered surface to prepare the surface even and smooth complete in specified areas as per specified patter. (Birla make) (including cost of all material, leads, lifts and carriages etc upto site of work complete).2 mm thick (CEILING & plastered wall)
48Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
49Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
50Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.(Crushed)
51Providing and fixing poly corbonate corrigated sheet roofing of approved quantity upto any pitch including fixing withpolymer coating with J,L,hooks,bolts & nuts, 8mm thick dia G.I bituminous washers. Complete job
52Providing and fixing Track deck CRIL make or equivalent H.I. rib profiled sheets 1000 to 1020 mm cover width 28-35 mm high crests at 250 to 255 mm T.C.T(total coated thickness) high tensile S.M.P Galvalume steel. The sheets shall have wide panes with 3 no stiffing ribs, effective water shedding and special male/female ends with full return legs on side Lapps for purlins support and anti-capillary flute inside Lapp. The sheets shall have a hot dip metallic coated of zinc and aluminum (150 gms /sm) zinc/aluminum coating mass total on both sides AZ-150 as IS -1397 ,550 MPA yield stress. Providing silicon modified polyester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of S.M.P over 5 micron polyester back coat over 5 micron primer coats on both surfaces including side and end Lapp and using 8mm Galvalume hex self-drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all sides and end Lapps etc (.measured for unit of laid area) (0.50 mm thickness )
53Providing and fixing precoated galvanised steel sheet roofingaccessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges/Valley plain (500 - 600mm)
54Pointing on brick masonry in lime Surkhi (I Lime: 2 Surkhi ) including finishing the joints with lime surkhi pigments to give a local heritage touch as per the directions of Engineer incharge upto desired height complete in all respects. (Including all lead, lift, labour, materials, tools, plants complete as per specification and as directed by Engineer in Charge.
55Providing and Fixing of 50mm dia stainless steel railing of 304 grade of hallow tube 1.6 mm thick of Jindal/Salem make or equivalent including welding and fixing with stainless steel machine screws for making required size and shape, buffing etc. Complete and fixing stainless steel balusters upto 900 mm height and S S tubes, three in one installed horizontally including cutting, welding, grinding to required shape and size by required steel dash fasteners, nuts, bolts, screws ,etc. in floors and treads including providing SS shoe at each balusters complete as per architectural drawings and as per the directions of engineer incharge including cutting of granite/marble floors and fastening with lead grouting if required, complete in all respects.
56Providing & fixing of stainless steel nevel post (Ornamental ) including top ball of AISI 304 grade of required height duley anchored to floor with dash fasteners . Height of the nevel post shall not be less than 1050 mm above the finished skirting level all complete as per architectural drawings (including cost of all material, leads, lifts and carriages etc upto site of work complete).Complete as per the directions of Engineer incharge.
57Providing and making 125mm Ornamental Cement Moulding of Ratio 1:1 (1cement 1sand) Including all materialfrom source to site and scaffolding, Inclusive of white exterior paint, and design to be approved by Engineer incharge.
58PLUMBING AND SANITARY INSTALLATIONS
59I-China Ware
60Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
61W.C. pan with ISI marked white solid plastic seat and lid.
62Providing and fixing Under Counter wash basin,with 32 mm Waste Coupling and other allied accessories including cutting and making good the walls wherever required:-
63White Vitreous China Under Counter Wash basin.
64Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
65Kitchen sink with drain board
66510x1040mm bowl depth 250mm
67Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
68II-C.P Fitting and Accessories
69Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing
70Rectangular shape 1500x450 mm
71Providing and fixing toilet paper holder with Flap made out of C.P Brass
72Providing and fixing C.P Brass Soap Dish.
73Providing and fixing CP brass towel rail complete with CP brackets fixed to wooden cleats with CP brass screws 600 mm long .
74Providing and fixing CP Short Body Bibcock with Valve Flange
75Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931
76Providing and fixing CP Brass wall mixer ofquality & make as approved by Engineer in charge.
7715 mm nominal dia
78Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge.
79Providing and fixing CP Brass Health Faucet. ofquality & make as approved by Engineer in charge
8015 mm nominal dia
81Providing and fixing Stainless Steel Retractable Sink Basin Water Drain Pipe of approved quality & make and as per the direction of Engineer-in-charge. (For Kitchen Sink)
82Providing and fixing CP Brass Sink Mixer with Regular Swivel Spout of quality & make as approved by Engineer in charge.
83III-SOIL, WASTE AND VENT PIPES
84Providing and fixing on wall face un-plasticized Rigid PVC water pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.including all fittings plain bend,tee,trap,door bend,collar etc as per directed by Enginer I/C
85110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B
8675 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B
87Providing and fixing of Rain Water pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design .etc. complete including jointing.
88110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-A
89Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. Makes:- Astral/SFMC/Finolex
90Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mmnominal size) finished with a floatingcoat of neat cement complete as perstandard design :
91Inside size 90x80 cm and 45 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) :
92With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5
93Supply, Installation of PVC Gully Trap of Size 110 mm
94Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of P.V.C pipes including bed concrete as per standard design :
95110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B
96IV: WATER SUPPLY
97Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply includingall PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge.
98Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good thewall etc.
9915mm nominal outer dia pipes
10020mm nominal outer dia pipes
10125mm nominal outer dia pipes
102Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply includingall PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge.
103Internal work-exposed on wall with clamps at 1.00 meterspacing
10420mm nominal outer dia pipes.
10525mm nominal outer dia pipes.
10632mm nominal outer dia pipes.
10740mm nominal outer dia pipes.
108External work including trenching and refilling etc.complete
10950mm nominal outer dia pipes.
110Providing and fixing unplasticised PVC connection pipe with brass unions:
11145 cm length15 mm nominal bore
112Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks
113Supplying and Fixing of Elastomeric foam Insulation made from Nitrile Rubber with Density not less than 50 Kg/Cu.m,Thickness 10 mm for a Temp Range of -40 Deg C to 105 Deg C
114V-PVC STORAGE TANKS,VALVES AND GEYSERS
115Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
11650 mm Diameter
11740 mm Diameter
11832 mm Diameter
11925 mm Diameter
120Providing & Laying of Pre Cast RCC Rings of concrete grade (M-20) 1200mm dia for making of Sokage pits inclusive of all earthwork,laying of precast rings,with RCC slab top & interconnecting with pits which shall be made Staggerly or as directed by Enginer I/C
121Making septic tank of Outer dimensions (5m x 2.5m) with a clear depth of 2.5m With F.P.S. bricks with class designation 75 n (Outer walls 0.35m thick) in cement mortar 1:4 (1 cement: 4 coarse sand) including 2 no Baffle walls (0.23m thick), Floor concrete 1:2:4 mix 75mm thick over pcc 1:4:8 125mm thick, RCC Slab At Top (150mm Thick), 2 No C.I Covers (Heavy Duty) inside plastering 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement complete including earthwork & stone soling 150mm as per standard design specified/approved by Engineer in charge
122Providing and fixing on wall 50 LTRS Electric Geyser with ABS Body.
123Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
124Supply,Installation,Testing and Commissioning of Open Well Submersible Pump with a Discharge of 8.0 Cu.m/hr @Head of 45 Meters Complete with all accessories including header Pipes, allied materials and automatic Control Panel.
125Note:-The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site work and all extra charges including dewatering if any during the execution of work complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56388614
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 5.82 Crore
LAST DATE 29-07-2026
Authority
Authority Name Sher-E-Kashmir University Of Agricultural Sciences & Technology
Work Description Tender for Construction Of Hostel At Mrcfc Khudwani, Skuast-K (Capex).
Basic Detail
Tender No E-NIT-23 of 2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 09 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 5.82 Crore
Tender Fee 15000
EMD 11.65 Lakhs
Exemption Not Available
Document List
BOQ_1022529.xls
d8b213e2-4431-4418-918f-c885f118dafd.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1022529.xls

html

d8b213e2-4431-4418-918f-c885f118dafd.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders