Law and Justice Local Bodies Closing in 8 days TDR #56385562

Tender For Installation Of Solar Submersible At Baharan Paschim Majhi Para Under Gangatikuri Gram Panchayat (Scheme Id- 118336823 )

Issued by Local Bodies · Purba Bardhaman, West Bengal
Tender Value
3.13 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
8 days left
EMD
6273
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Purba Bardhaman → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of Solar Submersible At Baharan Paschim Majhi Para Under Gangatikuri Gram Panchayat (Scheme Id- 118336823 )

BOQ

Name of Work:- INSTALLATION OF SOLAR SUBMERSIBLE AT BAHARAN PASCHIM MAJHI PARA UNDER GANGATIKURI GRAM PANCHAYAT (Scheme id- 118336823 )
Sl. No. Item Description
1Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (i) 50 mm dia. boring etc.
2Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia (ii) 100 mm dia. boring etc.
3Supply of PVC pipes & fittings Schedule 80 (medium duty) ……….Pipes as per IS : 1239 (Part - I). [ P- 14 / 19(iii) ] a) Reducing socket- i) 125 X 80mm
4Supply of G.I. pipes of TATA make including necessary sockets. [ P- 102 / 1 ] j) (i) 100 mm dia. medium quality
5Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (Supreme/Oriplast/swastick/Utkarsh) (i) 50 mm dia.
6Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (Supreme/Oriplast/swastick/Utkarsh) (ii) 100 mm dia.
7Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality (P-56, Item-27)
8Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (i) 75mm dia
9Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (i) 50 mm dia (P-52, I-6)
10Supplying fitting and fixing PVC pipes for underground works …… PVC schedule 80 colume pipes 32 mm dia. (Vide Sl No -9 of PHE Sch.) COLUMN PIPE
11Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilaye 2000 ltr capacity
12Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). .. .No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work i) 15 mm dia
13Supplying, fitting and fixing bib cock or stop cock. (f) (i) Polythene Bib Cock / Stop Cock (HD)
14Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone... bottom, bailing out water as required complete. [ P - 1 / 2 ] (a) Depth of excavation not exceeding 1,500 mm.
15Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolid……. [ P - 5 / 4 ] (a) Do - by fine sand
16Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. (3rd cori p-1, sl-1)
17Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. [ P- 24/4 ]
18Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as perrelevant IS codes. [ P - 26 / 10 ] In ground floor & foundation. a) Pakur Variety
19Brick work with 1st class bricks in ement mortar (1:6) [ P - 15 / 8 ] (a) In foundation and plinth
20125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.[P-16/16] In Gr. Floor
21Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,b…….. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel In Gr. Floor
22Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks …. [ P - 42 / 36 ] f) 25 mm to 30 mm shuttering withoutstaging in foundation
23Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering c…... [ P- 189 /1 ] (i) With 6:1 cement mortar (c) 15 mm. thick plaster In Gr. Floor
24Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering c…... [ P- 189 /1 ] (ii) With 4:1 cement mortar (c) 10 mm. thick plaster
25Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
26(b) Priming one coat on timber or plastered surface with synthetic oil...
27(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including ……..
28Painting with best quality synthetic enamel paint of approved make and brand ……. : (a) On timber or plastered surface : .. (iv) Two coats (with any shade except white)
29Painting with best quality synthetic enamel paint of approved make and brand ……. :(b) On steel or other metal surface :(iv) Two coats (with any shade except white)
30Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m P-64 Sl-35
31Solar Module: Supply , transport , installation and commissioning of ISI marked Solar Modules as per following specification: 1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology / module with bifacial cell. 3. Standards: ISI marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710 4.Modules must qualify to IS 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill factor: More than 75% . 7. Module wattage mismatch in the SPV array: within ±3% 8. Wattage output warranty:Should not be less than 90% at the end of 10 years and 80% at the end of 25 years. 9.The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see Cl. no. 2.1 of technical specification . (Sor of WRIDD chapter 12.00 SL-01) a) For 1 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 900 - 1200 Wp. (Solar Submerssible pump)
32M.S. structural works in columns, beams etc. with I) For structural members of specified sections weighing less than22.5 Kg./m using angle equal size of 50X6 mm @ 4.50 Kg/Mtr i) For structural members of specified sections weighing less then 22.5 kg/Mtr (Vide Page 99 of 315 it. -1 3rd Corriendum)
33Power conditioning unit with enclosure :Supply , transport , installation and commissioning of Solar Power conditioningUnit consisting of following components and features: 1) Variable frequency Drive with inbuilt MPPT, voltage rangesuitable for operating pump-motor set of 1HP to 20 HP, detail mentioned in Cl.6.12) Power input : DC source for 1HP, 2HP and 3HP.3) Power input : AC / DC source or hybrid for 5HP and above.4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5HP and 10 HP, 40 ampfor 15 to 20 HP as per IS/IEC 60947-25) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 ampfor 15 to 20 HP as per IS/IEC 60947-2 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5HP and 7.5 HP, 40 ampfor 10 HP, 63 amp for 15 to 20 HP 9) Reverse protection diode 1600 VDC with heat sink.10) Data Logger.11) Remote monitoring system.12) Should have built –in EMC filters .13)IP 65 glands for cable in and out. 14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(l). ( SOR-WRIDD , chapter-12, Page no-2, Item -3.a ) a) For 1 HP capacity Pump-motor set with AC / DC or hybrid input (For Solar Submerssible)
34Supply and instalation of 80 mm bore well 1 HP Submesible pump (Kirloskar/ Crompton/ C.G/ K.S.B./CRI or other approved brand as per direction of EIC ( AC/ DC supply 80 to 110 Volt outlet 32 mm )
35Eathing with 50mm dia. GI pipe 3.64 mm thick x 3.040mts long and 4 SWG GI ……… TATA medium GI pipe ( SOR-WRIDD , chapter-12, Page no-2, Item -5 )
36Cable and Accessories :Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit andother accessories as per followings with necessary connection with the Solar PVModule, MPPT etc.i. 4.0 Sq mm single core multi studs - 5m(for 1HP/2HP/3HP) & 20m(for5/7.5/10/15/17.5/20 HP)ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc (SOR-WRIDD, Ch-12, P-02, SL-04) a) For 1 HP/2 HP/3HP per structure (For Solar Submerssible)
37Collecting sample of water for bacteriological and chemical test from any....……..complete in all respect as per direction.
38Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
39Supplying and filling up of the annular space between the Well Pipe and the bore hole by coarse sand including watering as necessary as per direction of the Engineer-in-Charge.WRDD/P-7/It.-3
40Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia
41Supplying fittings, fixing display board….
42Add GST @ 18% (It 1-8)
43Add Cess @ 1% (It 1-9) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56385562
AUTHORITY Local Bodies
TENDER VALUE 3.13 Lakhs
LAST DATE 18-07-2026
Authority
Authority Name District Magistrate
Work Description Tender for Installation Of Solar Submersible At Baharan Paschim Majhi Para Under Gangatikuri Gram Panchayat (Scheme Id- 118336823 )
Basic Detail
Tender No 01/2026-27/PS
Bidding Type Tender
Location
City Purba Bardhaman
State West Bengal
Key Dates
Publish Date 09 Jul 2026
Submission Date 18 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 3.13 Lakhs
Tender Fee Ref. Documents
EMD 6273
Exemption Available
Document List
5a32d02f-c4c3-4742-85d3-2cc0636dde93.html
BOQ_5086178.xls
Tendernotice_1 (15).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

5a32d02f-c4c3-4742-85d3-2cc0636dde93.html

xls

BOQ_5086178.xls

pdf

Tendernotice_1 (15).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders