Tender For Bifurcation Of 11 Kv Line 400 Feeder Enamating From 33/11 Kv Dariyapur Substation To Lolepur Substation Due To Overload Of 10 Mva Power Transformer At Dariyapur Substation And Recondcutoring Of Old & Jarjar And Long Spaned 11 Kv 400 Feeder
Tender Overview
Project Description
Tender for Bifurcation Of 11 Kv Line 400 Feeder Enamating From 33/11 Kv Dariyapur Substation To Lolepur Substation Due To Overload Of 10 Mva Power Transformer At Dariyapur Substation And Recondcutoring Of Old & Jarjar And Long Spaned 11 Kv 400 Feeder Emanating Form 33/11 Kv Substation-Dariyapur The Head Of Business Plan 2026-27 Under Edd, Sultanpur.
BOQ
| Sl. No. | Item Description |
| 1 | PART-A (Material) |
| 2 | Following Materials Supplied by the Contractor :- |
| 3 | Earth Wire Clamp With Boult & Nut. |
| 4 | Stone Pad 300x300x75 mm. |
| 5 | Cross Arm Holding Clamp. |
| 6 | Clamp for T-off with bolts & nuts. |
| 7 | Holding Clamp for top channel TPMO & Fuse Set etc. with Bolts & Nut. |
| 8 | Stay Clamp. |
| 9 | Stay Loop Insulator. |
| 10 | GI Pipe 6\\" Dia |
| 11 | HDPE Pipe 140mm. |
| 12 | Safe carriage/cartage of following items from Store Centre, Sultanpur to work site including loading, unloading and proper stacking and return back of balance material form site to store at Sultanpur (distance within 0-50 Km.) |
| 13 | Safe carriage of PCC Pole 8.5 Mtr. |
| 14 | Safe carriage of ACSR Rabbit Conductor. |
| 15 | Safe carriage of 11 KV XLPE Cable 3x185 sq.mm. |
| 16 | Safe carriage of Cable Jointing Kit O/D 3x185 sq.mm. |
| 17 | Safe carriage of Other Line Materials. |
| 18 | Dragging of PCC Pole from site to pit point. |
| 19 | Fabrication & Erection of Single Pole 8.5 Mtr support on PCC including digging of pit & fixing of all accessories and clamps including fixing of G.I. Barbed Wire and Danger Board provided by contractor as per RESPO norms. |
| 20 | Grouting of Structure by digging of pit 1.83 Mtr. Deep for 8.5 Mtr PCC Pole foundation is provided with help of steel or wooden frames, groutung with 1:4:5 Ratio cement, sand & first class brick ballast 0.285 cu mtr for 8.5 Mtr PCC Pole plinthing 0.3 Mtr above G/L and Proper plastering as per RESPO norms. |
| 21 | Earthing of 8.5 Mtr PCC Pole as per RESPO norms. |
| 22 | Laying Stringing & sagging of New ACSR Rabbit Conductor including binding jumpering etc as per RESPO norms. |
| 23 | Laying of cable with HDD Method Using with HDPE Pipe (160 mm OD PN-4 PE – 80 Grade UV stabilized HDPE pipe as per IS: 4984 of 6 metre) 11 KV XLPE Cable 3x185 sq.mm as per RESPO norms. |
| 24 | Hanging Hoisting & clamping and G.I. Pipe Channel nut & Bolts 3x185 sq.mm XLPE 11 KV Cable (40 Mtr.) (Cost of all accessories will be borne by contractor) as per RESSPO Norms. |
| 25 | Installation and Fixing of Heat Shrinkable Type Cable joiting Kit 3x185 sq.mm XLPE Cable Box as per RESPO norms. |
| 26 | Dismentalling of old conductor loading unloading & proper stacking from work site to store center sultanpur. as per RESPO norms. |
| 27 | Clearance (NOC) and Security from Indian Railway Permission for Energization and laying of Underground Cable of 11 KV Line with the condition for actual amount paid by contractor, As per Receipt Produce with bill at time of payment. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender