Tender For Replacement Of Old Split Type Air Conditioner With New Split Type Air Conditioner (Hot & Cold) In Court Room No. 43 And Pillar Type Air Conditioner In Lok Adalat Bench (B-14) At Punjab And Haryana High Court Sector-1, Chandigarh. (Ch. To 4
Tender Overview
Project Description
Tender for Replacement Of Old Split Type Air Conditioner With New Split Type Air Conditioner (Hot & Cold) In Court Room No. 43 And Pillar Type Air Conditioner In Lok Adalat Bench (B-14) At Punjab And Haryana High Court Sector-1, Chandigarh. (Ch. To 4059 construction of Admin. Of Justice)
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). .E&M DSR 2025 32.2 |
| 2 | Inverter Type – Hot & Cold . |
| 3 | 1.5 TR with 5 Star BEE Rating .32.2.6 |
| 4 | Make: Carrier /Hitachi /Mitshubishi /Daikin /Voltas /Bluestar or any other make as per approved make list. . |
| 5 | Minimum Cooling Capacity Rating: 5000 watts and above. . |
| 6 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .Civil DSR 2023 10.25 |
| 7 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works .10.25.2 |
| 8 | Supplying and fixing Tower/pillar type (Vertical type) Cooling only Air Conditioner with 01 outdoor unit with following specification of make: Carrier, Voltas, Blue star, Hitachi .NSR |
| 9 | Tonnage: 4.0 (+/-10%) . |
| 10 | Cooling capacity: 48000 BTU per HR . |
| 11 | Refrigerant: Eco Friendly (R-410A/R-32 Gas) . |
| 12 | Three phase supply . |
| 13 | Voltage: 415 Volts(+/- 10%) 50 Hz Three phase . |
| 14 | with LCD display and Remote . |
| 15 | Including cost of MS Stand . |
| 16 | Indoor noise Level: Not to exceed 55dB . |
| 17 | Providing and fixing of voltage stabilizer suitable for 2 TR air conditioner capacity 15 Amp. Working range 150 VAC - 285 VAC with low and high voltage cut off protection built in thermal overload protection, digital/analog display for input/output voltage with wall mounting metal cabinet, complete of make V-Guard model VND 500 or equivalent model of Deol, Microtech, Luminous. .NSR |
| 18 | 5 KVA capacity . |
| 19 | Providing & Fixing of Powder coated ready made heavy duty out door stand for Split out door as per site requirement to the entire satisfaction of Engineer- in Charge. .NSR |
| 20 | Providing and Fixing of PVC Rigid drain Pipe complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials Diplast Or Equalivent. .NSR |
| 21 | Providing and Fixing of 22 gauge soft copper piping of size 3/8\\" / 5/8\\" or as per original manufacturer technical specification for A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter No's of both 3/8” & 5/8” with insulation. Make Rajco tubes, Mandev, Maxflow, Totaline. .NSR |
| 22 | Providing & fixing of 3 core 2.5 sqmm flexible copper wire as per specifications Makes Havell, Polycabs or Finolex complete as per site .NSR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender