Tender For General-Providing Ups At Pwd Roads Sub Division Office Tirur, Malappuram Dt.-Ups Work-General Electrical Work
Tender Value
2.79 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
5 days left
EMD
6998
Bank guarantee accepted
Document Fee
620
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Providing Ups At Pwd Roads Sub Division Office Tirur, Malappuram Dt.-Ups Work-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | SITC of UPS |
| 2 | OD74896/2026-2027:Supply, Installation and commissioning of 5 KVA/120VDC Pure sine wave UPS the following specification. Capacity 5 KVA, UPS, Nominal input voltage 230+/-25% VAC, Single Phase Input Single Phase output, Nominal Input frequency 50 HZ +/_ 5%Hz, Nominal output voltage 230 V AC Single phase, Output voltage regulation +/-1%, Manual Bypass Facility, Nominal output frequency 50 Hz, Output frequency tolerance +/-1%, Ventilation Forced Air cooled, LED/LCD Display for Mains on, Inverter on, Battery Low, Over Load, Trip, Load Percentage, Common Alarm Battery low, Over load with 10 nos of 12V/100Ah Tubular Battery with Battery Rack and accessories. 3Year Onsite warrenty for UPS and Battery (make UPS Hykon, Luminous, Zenrise, Zenster and Battery Hykon, Luminous, Exide ) |
| 3 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 4 | OD74891/2026-2027:Supply Conveyance, installation, testing and commissioning of 40A, 4Pole pole, Three phase 415 volts, MCB type change over switch in the existing MCB DB complete with connections. |
| 5 | OD74892/2026-2027:Supply Conveyance, installation, testing and commissioning of 40A, double pole, single phase 240 volts, MCB type change over switch in the existing MCB DB complete with connections. |
| 6 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 7 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 8 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 9 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 10 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 11 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 12 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 13 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 14 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 15 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 16 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender