Tender For annual repair & maintenance of Non Residential Building Under Sub Division-Iv, Nacd, Apwd, Mayabunder.Sub Work:- Providing Inverter Circuit Wiring For Rooftop Solar Plant Of Various Apwd Buildings Under Section-Iii (E&M) Sub Division-Iv, N
Tender Overview
Project Description
Tender for annual repair & maintenance of Non Residential Building Under Sub Division-Iv, Nacd, Apwd, Mayabunder.Sub Work:- Providing Inverter Circuit Wiring For Rooftop Solar Plant Of Various Apwd Buildings Under Section-Iii (E&M) Sub Division-Iv, Nacd, Apwd, Mayabunder.
BOQ
| Sl. No. | Item Description |
| 1 | AE Office Swadeshnagar |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | ii) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | iii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 5 | iv) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)i) 6 way , Double door |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) Single pole |
| 8 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) 40 A |
| 9 | APWD inspection Bunglow at Betapur |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 12 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 13 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)i) 6 way , Double door |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) Single pole |
| 16 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) 40 A |
| 17 | JE (E&M) Office, Swadeshnagar |
| 18 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.i) 2 X 1.5 sqmm + 1 X 1.5 sqmm earth wire |
| 19 | 2 X 2.5 sqmm + 1 X 2.5 sqmm earth wire |
| 20 | 2 X 4 sqmm + 1 X 4 sqmm earth wire |
| 21 | 2 X 6 sqmm + 1 X 6 sqmm earth wire |
| 22 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)i) 6 way , Double door |
| 23 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) 40A |
| 24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) Single pole |
| 25 | JE Office cum Residence Swadeshnagar |
| 26 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 27 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 28 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 29 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)i) 6 way , Double door |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) Single pole |
| 32 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) 40 A Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender