Tender For Repair Of Damaged Floor Tiles, Kota Stone, Broken Roof Sheet, Joineries, Cup Boards, Painting Of External Surfaces In Various Location At Burki & Tpt Lines And Replacement Of Feeder Pillar Boxes At Namkum & Khojatoli And Repair Of Damaged
Tender Overview
Project Description
Tender for Repair Of Damaged Floor Tiles, Kota Stone, Broken Roof Sheet, Joineries, Cup Boards, Painting Of External Surfaces In Various Location At Burki & Tpt Lines And Replacement Of Feeder Pillar Boxes At Namkum & Khojatoli And Repair Of Damaged Point Wiring, Switch Socket Etc In Various Location At Veer Lines, Rezengla Lines & Nursing Lines Under Ge Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | Dismatling and taking down old unserviceable LT feeder pillar and Supply, installation, testing and commissioning of LT Feeder pillar not lss than 0.500x0.600x0.50m, outdoor type factory made (CPRI approved) with canopy, double door, front & back both side oenable type fixed with hinges and locking arrangement with Aldrop latches, fabricated of CRCA sheet, inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer 3.15 mm thick, gasket, rubberised gasket, supported on 50x50x6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 300 Amps rated capacity mounted on porecelain insulators totally enclosed chamber for protection 3 Phase 415 volt with suitable capacity aluminium bus bar/PVC copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & washers wih danger notice plate. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate complete all as specified and directed. |
| 2 | Servicing to LT Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc all as directed Note:- (1) Unserviceable parts replaced if any shall be measured & paid seperately under respective items. |
| 3 | Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size |
| 4 | Painting of LT feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc complete all as specified and directed. |
| 5 | Rewiring the LT feeder piller by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,after taking out the old unserviceable wiring all as directed. |
| 6 | Material and labour for replacement of LED type indicator lamp (RYB) (Set of three) complete all as specified. |
| 7 | Suupply and Fixing in replacement of Digital Amp Meter 0-250 Amp with including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 8 | Suupply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 9 | Supply and fix Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 |
| 10 | Supply and fix Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 |
| 11 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA Make :Havells, Indoasian, C&S,HPL |
| 12 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA Make :Havells, Indoasian, C&S,HPL |
| 13 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 25 KA Make :Havells, Indoasian, C&S,HPL |
| 14 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA Make :Havells, Indoasian, C&S,HPL |
| 15 | Material and labour plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations / filling around the post, Poles etc complete all as specified and as directed. |
| 16 | Supply & fix in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - (i)On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.(ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x4 mm. |
| 17 | Material and labour for GI earth strip of size 25 x4mm in ground not exceeding 40cm deep / fixing to wall / structure including taking down old strip complete all as specified and as directed. |
| 18 | Supply, install, testing & commissioning of LT bus bar panel \\"out-door type\\" of size 900 mm (height) x 750 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable & 4 side slanting canopy on roof top. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned double Al bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50X50X5 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation necessary earthwork and including the following accessories. BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos aluminiume conductor size 25X6, 350 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :- The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING :-MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 100 A - 01 Nos. (a) Spreader Link - 01 Set (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. |
| 19 | Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing serviceable tile to store & rubbish off the premises. |
| 20 | M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over 15mm thick screed bed in CM 1 : 6 complete all as specified. |
| 21 | M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical sufaces over 10mm thick backing coat in cm 1 : 4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete. |
| 22 | M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in cm 1:4 complete all as specified match |
| 23 | Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thick (below or above ground level). |
| 24 | M&L 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in leveling course. |
| 25 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons |
| 26 | M&L Pre-polished Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement screed bed in cm 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified. |
| 27 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering. |
| 28 | S & F, 6 mm thick Non-asbestos cement corrugated sheet fixed with ‘L’ type or ‘J’ type or cranked hook bolts. |
| 29 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 30 | S&F prepainted galvalume aluminium zink coating GI based corrugated/ semi - corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screw as per manufacturers instrution complete. |
| 31 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall and ridge,fixed with self tapping srews complete. |
| 32 | Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete. |
| 33 | S&F Mild Steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates |
| 34 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 35 | Demolition of brick wk masonry built in cement mortar incl all quoins arches pillars etc |
| 36 | M & L Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in CM 1:6 |
| 37 | M&L Rendering 10mm thick on fair faces of brick work or concrete surfacesand making even and smooth complete all as specified. |
| 38 | M&L for preparation of newly plastered wall surfaces and applying two coats of acrylic distemper over a coat of primer complete all as specified. |
| 39 | Taking down chowkhats or frame n exc 1.5 sqm with shutters (without taking off shutters from the frames). |
| 40 | Taking down chowkhats or frame exc 1.5 sqm but n exc 4.00 sqm with shutters (without taking off shutters from the frames). |
| 41 | Taking down Shutters of any description exc 1 sqm but n exc 2 sqm. |
| 42 | Taking down Shutters of any description n exc 1 sqm and refixing in same opening after alteration. |
| 43 | Taking down Shutters of any description exc 1 sqm but n exc 2 sqm and refixing in same opening . |
| 44 | S&F Pressed steel frames 105x60 mm for doors with one or more rebatesincluding necessary fixing lugs, hinges, lock strike plate, etc., complete as specified. |
| 45 | S&F Pressed steel frames 125x60 mm for doors with one or more rebatesincluding necessary fixing lugs, hinges, lock strike plate, etc., complete as specified. |
| 46 | M&L for plain cement concrete type B-0, 1 : 2 : 4 (using 12.5mm crushed stone aggregate) as in coping, filling chowkhat and holdfast complete all as specified. |
| 47 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 48 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colourPVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as perspecification & drawing |
| 49 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with particle board core supplying & fixing in frame at site as per specification & drawing |
| 50 | S&F 2nd class hardwood 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 51 | S & F 100 mm Butt hinges medium weight cold rolled mild steel. |
| 52 | S & F 75 mm Butt hinges extrucded aluminium alloy with galvanised mild stel hinge pin, anodised and fixed, type C-21. |
| 53 | S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete. |
| 54 | S&F of 150 mm size aluminium handles cast type anodised. |
| 55 | S&F 250mm long Aluminium alloy, anodised, sliding door bolts with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extructed section or cast aluminium alloy and fixed. |
| 56 | S & F 3mm thick plain sheet glass ordinary quality & glazing with oil putty n.exc 0.50 Sqm in each pane including hacking out old broken glass. |
| 57 | S&F 4 mm thick figured glass pin headed type with oil putty n exc 0.5 sqm in each pane complete including hacking out old broken glass. |
| 58 | S & F 5.5mm thick plain sheet glass ordinary quality & glazing with oil putty n exc 0.50 Sqm in each pane. |
| 59 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 60 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 61 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc . After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 62 | M&L Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; hold fast, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to fe.290.Gde-E-165 |
| 63 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 64 | M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 65 | Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc . |
| 66 | M&L for rendering 15 mm thick on fair faces of brick work / Concrete /stone surfaces in cement mortar (1:6) making finished even & smooth without using extra cement . |
| 67 | M&L for preparation of existing old or new wall/ ceiling surfaces and applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterioe paint of required shade with silicon additives @ 1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm . |
| 68 | M&L for preparation of existing old wall/ ceiling surfaces and applying one coat of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterioe paint of required shade with silicon additives @ 1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm . |
| 69 | M&L for preparation of new plastered wall surfaces and applying two coats of cement based paint of approved colour and shade. |
| 70 | M&L for preparation of old plasterd wall surfaces and applying one coat of cement based paint of approved colour and shade |
| 71 | M&L complete removal of existing treatment on walls and applying two coats of oil bound distemper of approved colour and shade over one coat of putty complete. |
| 72 | M&L for preparation of old decorated surfaces on walls and applying one coat of oil bound distemper of approved colour and shade |
| 73 | M&L Applying 3mm thick wall care putty on wall surfaces in layers wise and rubbing till obtaining smooth surfaces. |
| 74 | M&L for preparation of old decorated surfaces on ceiling surfaces and applying one coat of oil bound distemper of approved colour and shade |
| 75 | M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint of approved colour and shade |
| 76 | M&L for preparation of old painted steel or iron surfaces of any description not otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint of approved colour and shade |
| 77 | M&L for preparation of existing old wall/ ceiling surfaces and applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterioe paint of required shade with silicon additives @ 1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm . |
| 78 | Taking down carefully exising unserviceable copper/aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 79 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSHH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before. |
| 80 | One light point controlled by one, one way switch 5 Amps |
| 81 | One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 82 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 83 | One bell point controlled by one, bell switch 5 Amps |
| 84 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 85 | Description all as per above ser item No 79 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 86 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(Contractor should make good even distributed wall/surface as before.) |
| 87 | One light point controlled by one, one way switch 5 Amps |
| 88 | One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 89 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 90 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 91 | Description all as per above ser item No 81 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 92 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 93 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 94 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp (set of 3 switches) , including junction box complete all as specified. JAQUAR Cat Part No SWG-GRY-GL16A3G01 , Havells AHLPLCGV03, Anchor 21328WH |
| 95 | S & F for Modular Switch Socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp including junction box complete all as specified. JAQUAR Cat Part No SKG-GRY-GL16ASC1GS1, Havells ACGPTOFV03, Anchor 85366990 |
| 96 | S & F ceiling fan regulator rotary type heavy duty suitable to work on 230 volts AC supply including junction box and removal of old unserviceable one complete all as specified. JAQUAR Cat Part No SWG-GRY-GL1ARFSS, Havells ACYRFHG008, Anchor 84149030 |
| 97 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 98 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 99 | S & F ceiling fan regulator socketed, step type, 1 Module heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 100 | S & F ceiling fan regulator socketed, step type, 2 Module heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 101 | S & F for Bell push modular 6 Amps single module complete all as specified. |
| 102 | Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 103 | S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified. |
| 104 | S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified |
| 105 | S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified. |
| 106 | S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified. |
| 107 | S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked |
| 108 | S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed |
| 109 | S & F for wall mounted LED tube light fitting not less than 22 W, 220V, 4000K batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Cat Part phillips BN021 LED22S 4000K PSU GR, Jaquar BTI-WHT-LGLZU1X022XW or Havells- LINEBS22WLED865SPCWH |
| 110 | S & F for wall mounted LED tube light fitting not less than 22 W, 220V, 6500K batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Cat Part phillips BN021 LED22S 6500KPSU GR, Jaquar BTI-WHT-LGLZU1X022XW or Havells- LUMILINEBS22WLED865SPCWH |
| 111 | S & F for LED lights fitting not less than 20 W, 220V, AC box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Cat Part No Bajaj BCLSB 20 WH, Jaquar BTI-WHTLTBL01X020XC or crompton TCS-109-20-65-SL-DP-NWH. |
| 112 | S & F for LED 10 watts batten with decorative end caps complete all as specified and as directed. |
| 113 | S & F for Highly efficient LED Bulbs, 10 W, of make Bajaj, Havells, HPL complete all as specified and directed |
| 114 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 115 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping/conduit including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before. |
| 116 | One light point controlled by one, one way switch 5 Amps |
| 117 | One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 118 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 119 | One bell point controlled by one, bell switch 5 Amps |
| 120 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 121 | Description all as per above ser item No 106 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 122 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 123 | S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 124 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Make : Schneider, Havells, ABB. |
| 125 | S & F for sheet metal enclosure MCB DB VTPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB. |
| 126 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB. |
| 127 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB. |
| 128 | S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified. |
| 129 | S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 130 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 131 | S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 132 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 133 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 134 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 135 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshHH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 136 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 137 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender