Tender For Provn Of 02 X Toilet Block ( 04 X Wc) Including Septic Tank, Soakage Well And Sewage Line Against Job No. 15/24/Lbcw/2026-27 And Provn Of One Elevated Sentry Post Without Guard Room Against Job No.12/Rev/5S/2026-27 At Age B/R (P) Under Ge8
Tender Overview
Project Description
Tender for Provn Of 02 X Toilet Block ( 04 X Wc) Including Septic Tank, Soakage Well And Sewage Line Against Job No. 15/24/Lbcw/2026-27 And Provn Of One Elevated Sentry Post Without Guard Room Against Job No.12/Rev/5S/2026-27 At Age B/R (P) Under Ge861ews
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge. |
| 3 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed by Engineer-in- charge. |
| 4 | Material & Labour for Hardcore of broken stone or boulders ,gauge exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Material & Labour for Hardcore of broken stone or boulders ,gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 8 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 9 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 10 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Slabs supported on walls,beams and columns infloors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like Slabs supported on walls,beams andcolumns in floors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Chajjas complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. |
| 12 | Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Material & Labour for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Material & Labour for Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Material & Labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Material & Labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, in square, rectangular or polygonal on rough finished surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Material & Labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. on flat rough finished surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Material & Labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material & Labour Formwork to chullah hoods, chajjas,troughs and similar items including edges on flat rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Material and labour Brickwork with sub class 'B' old size burnt clay bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge. |
| 22 | Material & Labour for 100 mm thick PCC 1:4:8 ,Type-D2 ,using 40mm graded stone aggregates as in sub base of flooring complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material and labour for 75 mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection / path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge |
| 24 | Material & Labour for 40 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregates as in floor , finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material & Labour for 25 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregates as in floor , finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material and labour for Rendering 15mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material and labour for Rendering 15mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material and labour for Rendering 10mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material and labour for Rendering 10mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material & Labour for Non skid ceramic coloured joint free tiles , thickness 7mm to 8mm thick (square/ rectangular), colour as approved by Engineer-in-charge area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material & Labour for Glazed ceramic tiles 350 mm x 250mm x 7 mm/ 450 mm x 350mm x 7mm thick as in vertical surfaces , set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 32 | Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 34 | Material and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash over with and including one coat of chalk white primer complete all as specified and as directed by Engineer-in-charge. |
| 35 | Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A including distance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge. |
| 36 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Material and labour including preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described and applying two coat of syntheic enamal paint over and an including one coat of red oxide zinc chrome priemer complete all as specified and as directed by Engineer-in-Charge. |
| 39 | Supply and Fixing Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engineer-in-Charge. |
| 40 | Material and labour for 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as spd and directed by Engr-In-Charge . |
| 41 | Supply & Fixing factory made solid PVC door frame of size 50mmx47mm made out of 5 mm wood grain printed PVC shee twith mild steel square tube complete as per manufacturer specification & drawing complete all as specified and directed by Engr - in - Charge. |
| 42 | Supply & Fixing factory made solid panel PVC door shutter 30 mm thick (stiles) consisting of frame made out of mild steel tubes for top & bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC \\"C\\" channel having a PVC sheet strip of 20 mm with stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and botttom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement fixing in the frame at site as per specification ,drawing complete all as specified and directed by Engr - in - Charge. |
| 43 | Supply and fixing 100 mm butt hinges ,stainless steel complete all as specified and directed complete all as specified and as directed by Engineer-in-Charge. |
| 44 | Supply and fixing 150 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and complete all as specified and as directed by Engineer-in-Charge. |
| 45 | Supply and fixing 150 mm aluminium handle cast type, anodised, complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Removing excavated material of any type of soil not exceeding 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point . complete all as specified and directed by Engr- in- charge. |
| 47 | Returning filling including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 48 | Supply and Fixing One-Piece Vitreous China Wash Down Water Closet (W.C.) of pedestal pattern, white/off-white colour, complete with soft-close/smooth-action plastic seat cover and valveless syphonic action flushing cistern of 10 Ltr capacity, including all integral fittings, fixing accessories, inlet and outlet connections, seals, fasteners and all necessary components required for proper installation and functioning, complete in all respects as specified and directed by the Engineer-in-Charge. |
| 49 | Supply and Fixing Vitreous china wash hand basin, Vitreous china white, flat back, size of 550mm x 400 mm with Mild steel brackets, with and including cutting for and pinning in ends of brackets or erecting stand, with and including waste fittings of brass chromium plated ,with and including 32mm dia PVC waste pipe of required length complete all as specified and directed. as directed by Engineer-in-Charge. |
| 50 | Supply & Fixing Vitreous China bowl urinal flat back, size of 430 mm x 370 mm x 340 mm white (minimum), with grating and union for discharge pipe with and including 32mm bore PVC waste pipe complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and fixing Pillar taps, 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT or COLD' with long scrwed shanks and fly-nuts, screwed for iron pipe or for connection pipe complete all as specified and as directed by Engineer-in- charge. |
| 52 | Supply & fixing Bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in- charge. |
| 53 | Supply & fixing stop valve of 15mm bore , chromium plated with long shank and cup concealed type cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and as directed by Engineer-in- charge. |
| 54 | Supply & Fixing PVC connection 15 mm size PTMT nuts of length 600 mm complete all as specified and as directed by Engineer-in- charge. |
| 55 | Supply & Fixing soap dish vitreous china white size 160mm x 160mm x 90mm (approximate) all as complete all as specified and as directed by Engineer-in- charge. |
| 56 | Supply & Fixing 15mm bore GI tubing medium grade with all fittings to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply & Fixing 20 mm bore GI tubing medium grade with all fittings to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply & Fixing 20mm bore gun metal glove or gate valve (ISI Marked) with iron wheel head screwed both ends for iron pipe complete all as specified and as directed by Engineer-in- charge. |
| 59 | Supply & fixing Rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position with and including Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in-charge. Note: The rate of 20mm bore ball valves, high pressure of PTMT is included in this iterm and nothing shall be paid extra on this account. |
| 60 | Supply & Fixing 110 mm bore PVC (SWR) pipes single socketed (Type 'B' ISI Marked), in any length with rubber ring joints, laid in trenches/wall or in floors complete all as specified and as directed by Engineer-in- charge. Note: Earth work such as excavation, returning filling and removal shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 61 | Supply & fixing 110mm bore PVC (SWR) bends (Type 'B' ISI Marked) any radius with access door complete all as specified and as directed by Engineer-in- charge. |
| 62 | Supply & Fixing 110 mm bore PVC (SWR) junction double, (double T) (Type 'B' ISI Marked), equal or unequal complete all as specified and as directed by Engineer-in- charge. |
| 63 | Supply & fixing 110mm PVC (SWR) vent cowl (Type 'B' ISI Marked) complete all as specified and as directed by Engineer-in- charge. |
| 64 | Supply and Fixing Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engr-in-charge. |
| 65 | Supply and fixing 600mm x 450mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame / beading alround made of aluminium channel, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply & fixing PVC (SWR) floor trap 75 mm (Type 'B' ISI Marked), plain with grating including jointing with solvent cement all complete all as specified and directed by Engineer-in-Charge. |
| 67 | Material & Labour for Setting coat of 3mm thick in Cement Mortar 1:2, trowelled to even and smooth finish over with and including rendering 15mm thick in Cement Mortar 1:4 on fair faces of brick work finished surface even & smooth with using Liquid Water proofing compound complete all as specified and directed by Engineer-in-Charge.Note:- Liquid water proofing compound shall be measured and paid as supply only under appropriate item of Sch 'A' BOQ. |
| 68 | Supply only Liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge. |
| 69 | Material & Labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregates as in lintel upto 1.5m clear span, cills, steps; seismic and other similar bends, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and thelikeincluding weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. |
| 70 | Material & Labour for Precast cement concrete type 1: 2: 4, type-B1 (using 20 mm graded stone aggregates) as in cover slabs for manholes/ septic tank set in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-charge.Note:- Reinforcement shall be measured and paid separately under appropriate items of Sch 'A' BOQ. |
| 71 | Material and labour for PCC (1:3: 6) type C-2 using 40 mm graded stone aggregates as in concrete bed for drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 72 | Material & Labour RCC pipes class NP-2 with socketed ends laid and jointed complete of 150mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Material and Labour for Construction of soakage well of size 1.20 mtr dia x 3.00mtr effective depth including earth work such as excavation in any type of soil, returning filling and removal of earth work , foundation in PCC 1:3:6 Type-C-1 using 20mm graded stone aggregates, Honey combing Brick massony built with burnt clay old size bricks ,Top ring made with RCC M-25 Design Mix ,intercepting chamber and screen made with burnt clay old size brick with cement mortar 1:4, RCC M-25 Design Mix cover slab , 150mm bore salt glazed stoneware interconnecting pipes , filled with brick bats compete all as shown in drawing No.CESZ/TD-36/ST/20 SHEET 1/2 AND 2/2 DATED 22-02-2020 |
| 74 | Supply and installation of LLDPE (Linear Low Density Polyethylene )Septic Tank of approved make of 25 user capacity, conforming to relevant specifications, including excavation in all types of soil,providing and laying 100mm thick Plain Cement Concrete 1:4:8 Type D-2, using 40mm graded stone aggregates as in bedding for placing the tank in position, connecting inlet and outlet pipes, filling around the tank with suitable material, and making good the disturbed surfaces complete in all respects as directed by the Engineer-in-Charge. Note: The rate of 100mm thick Plain Cement Concrete 1:4:8 Type D-2, using 40mm graded stone aggregates, excavation and earthwork , filling the suitable material and making good the disturbed surfaces is included in this item and nothing shall be paid extra on this account. |
| 75 | Material & Labour for Rendering 5mm thick on other than fair faces of brick work or concrete surfaces bult in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 76 | Material & Labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engineer-in-Charge. |
| 77 | Supply & Fixing 2nd class soft wood Plain fillets. square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads exceeding 13 Sqcm and not exceeding 25 sqcm complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply & Fixing 2nd class soft wood Plain fillets. square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads exceedind 06 Sqcm and not exceeding 13 sqcm complete all as specified and directed by Engineer-in-Charge. |
| 79 | Supply & Fixing 2nd class soft wood Plain fillets. square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads not exceeding 03 sqcm complete all as specified and directed by Engineer-in-Charge. |
| 80 | Material & Labour for 4mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with screws to timber frame work in ceiling complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Supply & Fixing 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 82 | Supply and Fixing Factory made 35mm thick framed, panelled shutter (two panel) with lock rail made of 2nd class Hard wood and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge. Note: Butt Hinges, Tower bolts, Handles , sliding door bolts and painting shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 83 | Supply and Fixing 200mm long aluminium anodised barrel tower bolts of extruded section (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply and Fixing Butt hinges size of 100mm , medium weight cold rolled mild steel (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply & Fixing Mild steel work as in Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Material & Labour including preparation of newly wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamal paint over with and including one coat of pink primer complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Material & Labour including preparation of newely plastered Surfaces of wall and applying two coats of oil bound distemper over with and including one coat of Alkali resistant primer complete all as specified and as directed by Engineer-in-Charge. |
| 88 | Supply and Fixing 20mm dia (Outer diameter of pipes in mm) 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobialfusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed by Engineer-in-charge. Note: Earth work and excavation shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ. |
| 89 | Supply and Fixing 20mm dia (Outer diameter ) 3- layer PP-R gate valves (base insert ) as per site requirement complete all as specified and as directed by Engineer-in-charge. |
| 90 | Material and Labour for Cutting of existing PP-R pipe line of 20mm to 75mm bore and inserting with and including NEW PP-R TEE of appropriate size and taping new connection with all accessories complete all as specified and as directed by Engineer-in-charge. Note: The rate of supply and fixing of NEW PP-R TEE of appropriate size is included in this item.Hence bidder shall be quoted his rates accordingly and nothing shall be paid extra on this account. |
| 91 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches 5Amp/6Amp , socket outlet 5Amp/6Amp and fan regulator, for light / fan point controlled by one way switch 5Amp / 6Amp, top cover fixed with brass screws & cup washers, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Notes for serial item nos. 91.00 to 94.00 : (i) Switch piano flush type 5 Amp single pole one way , Switch socket combination 2 in 1, 3 pin, 5 Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ. |
| 92 | All as per srl item No.91.00 here- in- before but for One socket outlet, 5 Amps, same board complete all as specified and directed by Engineer-in-Charge. |
| 93 | All as per serial item No 91.00 of BoQ here-in-before but for socket outlet 5 pin 5Amp / 6 Amp on independent board complete all as specified and directed by Engineer-in-charge. |
| 94 | All as per srl item No 91.00 of BoQ here-in-before but 2.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked with and including one single core 2.50 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) as continues earth wire connected to earth dolly etc for 3 pin socket outlet 15 Amps with complete all as specified and directed by Engineer-in-Charge. |
| 95 | Supply and fixing Switch piano flush type 5 Amp single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 96 | Supply & Fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 240 volt (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 97 | Supply & Fixing Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal 240 volt (ISI Marked )complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply and fixing ceiling rose 3 phase/ PVC/ polycarbonated isolated body complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supply and fixing Lamp holder (Angular/Straight )ISI marked , insulated body , with back plate for batten fittings complete all as specified and directed by Engineer-in-Charge. |
| 100 | Supply and fixing LED lamp 10 Watt complete all as specified and directed by Engineer-in-Charge. |
| 101 | Supply and Fixing Decorative ultra slim linear LED 20 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 102 | Supply and Fixing LED Bulkhead luminaries 10 Watt including LED light driver holder and diffuser, ploycarbonate body and ribbed opal diffuser complete with lamp and all other accessories fitting arrangement as per manufacturer's instructions with and including electric connection connecting with using flexible copper wire twin core upto ceiling rose/ connector complete all as specified and as directed by Engineer-in- charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 103 | Supply & Fixing LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 104 | Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 4 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 105 | Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 106 | Supply and fixing MCB DP (Doubel Pole) 40 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 107 | Supply and fixing MCB SPN 32 Amp, rupturing capacity not less than 10 KA 'C' curve 230 V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge. |
| 108 | Supply and fixing Exhaust fan, plastic body AC single Phase. 230V of size 250mm sweep with, blades, and frame and louvers shutters including making circular hole in existing wall to accommodate exhaust fan and necessary civil work and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2.0 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 110 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 111 | Supply and fixing wall mounted fans complete with accessories, 230V, 450mm sweep complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender