Drinking Water Supply and Sanitation Government Departments Closing in 7 days TDR #56381549

Tender For Basicrateof Materialsforinclusion In The Schedule Of Rates For Government Of Jharkhand To Be Used In Different Civil Construction / Infrastructure Works And Repair Works.

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jul 2026
7 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Basicrateof Materialsforinclusion In The Schedule Of Rates For Government Of Jharkhand To Be Used In Different Civil Construction / Infrastructure Works And Repair Works.

BOQ

Name of Work:- BasicRateof MaterialsforInclusion in the Schedule of Rates for Government of Jharkhand to be Used in Different Civil Construction / Infrastructure Works and Repair Works.
Sl. No. Item Description
1Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump
2Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
3SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.
4i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
5ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
6iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
7iv) The module mounting structure should be hot dip galvanized according to IS 4759.
8v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
9vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
10vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
11viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
12ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
13x) The motor pump set should have a 5 years warranty.
14xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
15xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
16xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.
17xiv) With third party inspection before dispatch.
18xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.
19The following details should be marked indelibly on the motor pump set
20a) Name of the Manufacturer or Distinctive Logo.
21b) Model Number.
22c) Serial Number.
23Solar submersible motor pump (SPV DC Type)- 1 HP
241 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. (As per latest guide line of MNRE)
25Solar submersible motor pump (SPV DC Type)- 2 HP
262 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. (As per latest guide line of MNRE)
27Soft Starter
28Supplying of Electronic soft start starter conforming to IEC 60947-4-1/2 or latest standard of three wire system to operate on 440 Volt, 3 Phase, 50 Hz consisting of Main contactor AC- 3 Duty and 1.5 times of full load current rating, Suitable Thyristors, Ammeter with selector switch and CTs, Motor protection relay with protection CTs for protection against Single phasing (Current sensing), Under voltage and over voltage, Phase reversal & Over current relay having IDMT Characteristic.
29100 HP
30120 HP
31150 HP
32170 HP
33200 HP
34215 HP
35250 HP
36270HP
37300 HP
38335 HP
39HORIZONTAL SPLIT CASTING CENTRIFUGAL PUMP (1500 RPM) confirming to IS 1520
40Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM and efficiency shall be atleast 65%.
41Capacity in LPM : 500
42Head in Meter :
43Capacity in LPM : 750
44Head in Meter :
45Capacity in LPM : 1000
46Head in Meter :
47Capacity in LPM : 1250
48Head in Meter :
49Capacity in LPM : 1500
50Head in Meter :
51Capacity in LPM : 1750
52Head in Meter :
53Capacity in LPM : 2000
54Head in Meter :
55Capacity in LPM : 2250
56Head in Meter :
57Capacity in LPM : 2500
58Head in Meter :
59Capacity in LPM : 3000
60Head in Meter :
61VERTICAL TURBINE PUMP (WATER LUBRICATED) CONFIRMING TO IS1710/1989 (REAFFIRMED 2009) 1500 RPM SUITABLE FOR VERTICAL HOLLOW/SOLID SHAFT SQUIRREL CAGE
62Supply and delivery of Vertical type water/Oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging the following duty condition as given below due to all causes with surface discharge head confirming to IS 1710 and as amended as on date with accessories as per IS 5120/1977 (Reaffirmed 2011 ) and as amended thereafter to suit the site condition. The speed, No. of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 rpm. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required Nos. to suit the well depth, Rubber line shaft bearing of required Nos., C.I Bearing retainer of required Nos., 100 litre HDPE Pre- lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required Nos. to suit the well depth, Suction bell mouth of suitable size, M.S. clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete and efficiency shall be atleast 70%.
63Capacity in LPM : 500
64Head in Meter :
65Capacity in LPM : 750
66Head in Meter :
67Capacity in LPM : 1000
68Head in Meter :
69Capacity in LPM : 1250
70Head in Meter :
71Capacity in LPM : 1500
72Head in Meter :
73Capacity in LPM : 1750
74Head in Meter :
75Capacity in LPM : 2000
76Head in Meter :
77Capacity in LPM : 2250
78Head in Meter :
79Capacity in LPM : 2500
80Head in Meter :
81Capacity in LPM : 3000
82Head in Meter :
83Bulk Water Meter
84Providing, installing and giving satisfactory field testing of flanged ends Bulk water meter of following type and as mentioned below with FGI-250 cast iron body, class \\"B\\" conforming to IS: 2373, to read in metric system, along with manufacturer's test and guarantee certificate including cost of all materials and labour with ISI mark etc. complete.
85Removable mechanism type as per IS: 2373
86100mm dia
87150mm dia
88200mm dia
89250mm dia
90300mm dia
913500mm dia
92400mm dia
93450mm dia
94500mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56381549
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-07-2026
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Tender for Basicrateof Materialsforinclusion In The Schedule Of Rates For Government Of Jharkhand To Be Used In Different Civil Construction / Infrastructure Works And Repair Works.
Basic Detail
Tender No 02/CDO/Ranchi/SOR/2026-27(3rd Call)
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 09 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
5788751d-323c-4e2c-b392-ea69b06e18fe.html
Annexure-1.pdf
BOQ_156843.xls
Tendernotice_1 (14).pdf
Term.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

5788751d-323c-4e2c-b392-ea69b06e18fe.html

pdf

Annexure-1.pdf

xls

BOQ_156843.xls

pdf

Tendernotice_1 (14).pdf

pdf

Term.pdf