Tender For Repair & Maintenance Work Of Cr Gates (6 Nos) At Ch 15 Of Tawa Dam Lbmc Under Tawa Project Division Itarsi.
Tender Value
8.23 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
10 days left
EMD
16471
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshangabad → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair & Maintenance Work Of Cr Gates (6 Nos) At Ch 15 Of Tawa Dam Lbmc Under Tawa Project Division Itarsi.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing flat type uncladded rubber seals and stainless steel counter sunk bolts/ nuts/ washers of approved quality including cost of all materials, labour, removing existing worn-out/ damaged bulb type rubber seals from gates, cleaning surface, making holes in new seals, fixing new seals /bolts/ nuts/ washers tightly in position, labour, scaffolding etc., complete. 2.5mtrx6 gates=15 mtr |
| 2 | Supplying and fixing bulb type (musical note) uncladded rubber seals and stainless steel counter sunk bolts/ nuts/ washers of approved quality including cost of all materials, labour, removing existing wornout/damaged bulb type rubber seals from gates, cleaning surface, making holes in new seals, fixing new seals /bolts/ nuts/ washers tightly in position, labour, scaffolding etc., complete. 3.5 mtrx2sidex6 gates=42 mtr |
| 3 | Providing, fabrication, machining with straightening work of Guide Tee, Track, Sealing frame, Leaf frame or any part of gate's, complete as per drawing with testing, including cost of all materials, with machinery, labour, tools and tackles cutting, aligning, welding, finishing, cleaning, etc., applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint, etc., complete as per specifications and approved drawings with all lead and lifts, including packing and forwarding, transportation charges for structural steel components and other materials. Rate of work with all material. |
| 4 | Erecting work of fabricated gates, any parts of gate's and any accessories of gate's, complete as per drawing with testing, including cost of all materials required for completing the job like welding rods, tools tackles etc., with machinery, labour, tools and tackles cutting, aligning, welding, finishing, cleaning, etc., applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint, etc., complete as per specifications and approved drawings with all lead and lifts, including packing and forwarding, transportation charges for structural steel components and other materials. |
| 5 | Providing ,fixing,servicing and repair work of roller assembly as required on site including labour ,machinery and transportation charges complete work at site . |
| 6 | IInd stage design mix concrete with graded metal of max size 12.5 mm in gate groove & sill beam, after fixing and alignment of second stage parts, sill beam. Including cost of material, labour for shuttering, maxing, laying scaffolding consolidating, curing and cleaning & finishing / chipping as required complete. M-20 concrete. |
| 7 | Painting of Spillway gates, sluice gates, canal gates (both vertical or radial), stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class \\"B\\" primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 ± 5micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150±5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipment’s. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylot or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting.Up to 1.5m height |
| 8 | Painting of Spillway gates, sluice gates, canal gates (both vertical or radial), stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class \\"B\\" primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 ± 5micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150±5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipment’s. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylot or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting.Beyond 1.5m height |
| 9 | Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type Dam Shutter gates interchangeable consisting of sealing frame(embedded parts), skin plate of shutters, stiffeners, horizontal and vertical girders, guide, stainless steel flat, lifting hooks, Clits fasteners etc., with all accessories including frame & gate complete set for Barrage/Stop dam/waste weir /spillway including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, tools and tackles, seal fixing, applying one coat of zinc rich epoxy primer and three coats of cold applied coal tar epoxy paint, including primer coating, should not be less than 350 microns etc., Complete as per specifications and approved drawings, including packing and forwarding, transportation charges for structural steel components and other materials. |
| 10 | Supplying and fixing flat type uncladded rubber seals and stainless steel counter sunk bolts/ nuts/ washers of approved quality including cost of all materials, labour, removing existing worn-out/ damaged bulb type rubber seals from gates, cleaning surface, making holes in new seals, fixing new seals /bolts/ nuts/ washers tightly in position, labour, scaffolding etc.,complete. Rubber seal Flat type 75 mm x 12 mm uncladed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender