Housing Urban and Rular Development Government Departments Closing in 15 days TDR #56379576

Tender For Special Repair Works To Laying bituminous Road From Wallajah Road To Swami Sivanandhasalai. Compound Wall. Shifting Of Eb Meter Room In Amenity Block And Fire Fighting Systems To Refill The Fire Extinguishers For 4 Blocks Of 240 Mla Quarte

Issued by Government Departments · Chennai, Tamil Nadu
Tender Value
86.14 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
15 days left
EMD
53100
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair Works To Laying bituminous Road From Wallajah Road To Swami Sivanandhasalai. Compound Wall. Shifting Of Eb Meter Room In Amenity Block And Fire Fighting Systems To Refill The Fire Extinguishers For 4 Blocks Of 240 Mla Quarters At Omandurar Government Estate, Chennai-2.

BOQ

Name of Work:- Special repair works to Laying BT road from Wallajah road to Swami SivanandhaSalai. Compound Wall. Shifting of EB Meter room in Amenity Block and Fire Fighting Systems to refill the fire extinguishers for 4 Blocks of 240 MLA Quarters at Omandurar Government Estate, Chennai-2.
Sl. No. Item Description
1Providing and laying tack coat over the existing BT surface using 2 kg of bitumen emulsion (RS-I) per 10 sq.m for preparatory to another bitumen construction over it including cost of materials, labour charges, rental for machinery, fuel and other incidental charges etc., complete as per clause 503 of MORTH Rev-5
2Providing, laying 50mm consolidated thick bituminous Macadam using 0.20 cum of 26.50 - 13.20mm, 0.43 cum of 13.20-2.36mm and 0.08 cum of 2.36 mm & below size IRC metal with 37 kgs of VG40 Grade bitumen for premixing per 10 sqm including cost and conveyance of all material to CMP site, heating the bitumen, aggregate and mixing them in required temperature using central hot mix plan 20- 30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne vibratory roller to the required density etc., including labour for attending to paver to site etc., including hire and fuel charges for 20-30t CMP with bitumen boiler, tipper trucks, paver finisher, vibratory roller and all other tools and plant required, including all other incidental charges etc., complete as per specification using CMP as per clause 504 of MORTH Rev-5.
3Providing and laying bituminous concrete to 40mm thick using 0.13 cm of 19.00-9.50mm, 0.17cm of 9.50-2.36 and 0.26cu.m of 2.36 and below with 50.30 kgs of VG30/VG40 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity econveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanic paver to the specified grades and cross section and consolidated by 8-10 tonne vibrator/ pneumatic roller to the required density etc including labour and a attending to paver to site etc., including hire charges and fuel charges for 20-30 cmp with bitumen boiler, tipper trucks, paver finish, 9m paver finisher, vibratory /pneumatic roller and all other tools and plant required including fuel and all other incidental charges etc., complete as per specification using cmp as per clause 507 of MORTH Rev-5
4Providing and laying of hot applied thermoplastic compound 25mm thick including reflectorising glass beads as 250 gsm per sq.m. area thickess of 2.50mm is exclusive of surface applied glass beads ad per IRC 35. The finished surface to be level, Uniform and free from streaks and holes etc complete and as directed (as per MORTH specification no 803.
5Providing and fixing reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate / methyl methercrylate/ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D4280. The reflective raised pavement markers shall also confirm to the MoRT&H circular No RW / NH. 33023/10/ 97-DO. III dt 11.06.97. The height, width and length shall not be less than 15 mm, 90 mm and 100 mm and with minimum reflective area of 13 Sq.cm on each side and the slope to the base shall be (+/-) 5 degree. Each reflector shall have a CIL not less than values specified in Table 2 of said MoRT&H circular. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 (+/-) 2mm and height not less than 30 (+/-) 2 mm) from the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the Engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35 - 2015 guidelines and MoRT&H specification 804 etc., complete
6Removal of the Black Topped (BT) surface to 50 to 70mm depth using Milling machine, including conveying the milled waste materials away from the work site to an average distance including hire and running charges for the machine, conveyance charges, unloading at unobjectionable place, cleaning the milled surface as to avoid slippery including all other incidental charges etc. complete as per the direction of the departmental officers
7Brick work in Cement Mortar 1:5 using best quality of Second Class Ground Moulded Chamber Burnt Bricks of size 9\\" x 4-3/8\\" x 2-3/4\\" for foundation and basement including curing, etc., complete complying with standard specifiction.
8Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
9Repainting the old iron work two coats of synthetic enamel paint of approved quality and colour and brand including thorough scrapping preparation of surface and finishing neatly etc complete complying with standard specification and as directed by the departmental officers at site of work.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
10Repainting the walls with two coat of exterior emulsion paint of approved quality and colour including cleaning and thorough scrapping the walls and rendering the walls smooth with necessary brushes, labour charges and scaffolding charges etc., Complete complying with standard specification and as directed by the departmental officers.
11Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means
12Renewing and fixing Mild Steel Grills for windows and ventilators etc., including the cost of mild steel angles, plates, rods, cost of welding charges and one coat of priming coat etc., complete.(The design should be got approved by the departmental officers.)
13Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
14Supplying, fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers.
15Providing servicing, testing and refilling of stored pressure ABC (Mono Ammonium Phosphate) dry powder fire extinguisher of 4 kg/6 kg capacity, including complete dismantling, internal and external inspection of the cylinder, removal of old extinguishing agent, cleaning and drying of the cylinder, replacement of defective components such as O-rings, sealing washers, valve spindle, discharge hose, nozzle and pressure gauge (if required), refilling with fresh ABC Dry Chemical Powder (MAP 90 or 40% as specified) conforming to IS 14609, repressurising with dry nitrogen gas to the manufacturer's recommended pressure, leak testing, hydraulic testing (if due), repainting of the cylinder where necessary, fixing service tag and inspection label indicating the date of servicing and next due date, and carrying out performance testing, complete in all respects, in accordance with IS 15683, IS 2190, National Building Code (NBC) and the directions of the Departmental Officers.
16Providing servicing, testing and refilling of stored pressure Water CO₂ Fire Extinguisher of 9-litre capacity, including complete dismantling of the extinguisher, internal and external inspection of the cylinder, draining and disposal of the old extinguishing agent, thorough cleaning and drying of the cylinder, replacement of defective components such as O-rings, valve spindle, sealing washers, discharge hose, nozzle and pressure gauge (if required), refilling with clean water mixed with approved corrosion inhibitor as per the manufacturer's specification, repressurising with carbon dioxide (CO₂) gas to the required operating pressure, leak testing, hydraulic pressure testing (if due), repainting of the cylinder wherever necessary, fixing service tag and inspection label indicating the date of servicing and next due date, and carrying out functional testing, complete in all respects, in accordance with IS 940, IS 2190, the National Building Code (NBC), and as directed by the Departmental Officers.
17GST at 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56379576
AUTHORITY Government Departments
TENDER VALUE 86.14 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repair Works To Laying bituminous Road From Wallajah Road To Swami Sivanandhasalai. Compound Wall. Shifting Of Eb Meter Room In Amenity Block And Fire Fighting Systems To Refill The Fire Extinguishers For 4 Blocks Of 240 Mla Quarters At Omandurar Government Estate, Chennai-2.
Basic Detail
Tender No TNPWD/01-4 BCM/2026-27
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 09 Jul 2026
Submission Date 28 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 86.14 Lakhs
Tender Fee Ref. Documents
EMD 53100
Exemption Not Available
Document List
b5ce0809-e421-49df-bd9c-2b1094a49d4d.html
BOQ_823015.xls
conditionsBTroad.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

b5ce0809-e421-49df-bd9c-2b1094a49d4d.html

xls

BOQ_823015.xls

pdf

conditionsBTroad.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders